Electrical Characterization of XLPE Cable using Accelerated Water Absorption Test on Medium Voltage Power Cable and Partial Discharge Test on Power Cable with termination defects

被引:0
|
作者
Badmera, Vidushi [1 ]
Patel, R. R. [1 ]
机构
[1] GH Patel Coll Engn & Technol, Dept Elect Engn, Anand, Gujarat, India
关键词
XLPE; Dielectric Strength; Capacitance; Dissipation Factor; Stability Factor; Partial Discharge; FEMM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
XLPE cables have high dielectric strength and excellent ageing characteristics in dry environment. But a problem that appears, especially in case of underground cable, is the effect of water absorption on the insulation of the cable. Hence this papers firstly aims at presenting the results of variation of Capacitance, Dissipation Factor, Stability Factor and Relative Permittivity, with respect to water absorption. Partial discharge is an important parameter measured as a part of routine test for the power cables in all the cable manufacturing industries. Hence the paper secondly aims at creating the termination defects, purposely, on the newly manufactured cable and analyze the variation in the value of partial discharge by performing partial discharge test on this cable. The increase in the value of electric field stress at the defects is analyzed by simulation using FEMM Software.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Partial Discharge Measurement for Cable Terminators of XLPE Power Cable
    Apiratikul, P.
    Boonchiam, P.
    Plangklang, B.
    Suwanasri, T.
    2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 573 - 576
  • [2] Discuss AC voltage withstand test of XLPE power cable
    2005, Science Press, Beijing, China (31):
  • [3] Partial Discharge Characterization of Cross-Linked Polyethylene Medium Voltage Power Cable Termination Defects at Very Low Frequency (0.1 Hz) and Power Frequency Test Voltages
    Fynes-Clinton, Daniel
    Nyamupangedengu, Cuthbert
    IEEE ELECTRICAL INSULATION MAGAZINE, 2016, 32 (04) : 15 - 23
  • [4] Partial Discharge Characteristics and Development of Typical XLPE Power Cable Insulation Defects
    Zhao, Xuefeng
    Pu, Lu
    Ju, Zeli
    Ren, Shuangzan
    Duan, Wei
    Wang, Jianhui
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 623 - 626
  • [5] Study on wideband sensor of partial discharge for XLPE power cable
    Chen, XL
    Cheng, YH
    Rong, MZ
    Zhang, SF
    Xie, HK
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 203 - 206
  • [6] Partial discharge detection in XLPE power cable with CT sensor
    Luo, JH
    Feng, J
    Yuan, J
    Ma, CJ
    Qiu, YC
    ICSD '01: PROCEEDINGS OF THE 2001 IEEE 7TH INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, 2001, : 400 - 403
  • [7] Partial Discharge Characteristics and Mechanism of Medium Voltage Power Cable Defects under Different Voltage Stresses
    Wang, Li
    Chen, Junbai
    Li, Hongjie
    Jin, Lei
    Zhao, Kun
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2023, 18 (10) : 1598 - 1606
  • [8] Propagation and attenuation characteristics of partial discharge signal in high voltage XLPE power cable
    Liu B.
    Gu X.
    Xu Y.
    Liao Y.
    Xia R.
    Gaodianya Jishu/High Voltage Engineering, 2016, 42 (08): : 2588 - 2595
  • [9] Investigation on Partial Discharge of Power Cable Termination Defects Using High Frequency Current Transformer
    Suwanasi, Cattareeya
    Suwanasri, Thanapong
    Fuangpian, Phanupong
    Ruankon, Sayan
    2013 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2013,
  • [10] Partial Discharge Characteristics of Typical Defects in XLPE Cable Under DC Voltage
    Du H.
    Guan H.
    Chen X.
    Hou S.
    Yang M.
    Wang X.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (02): : 555 - 563