High-Resolution Mass Spectrometry for In Vivo Proteome Dynamics using Heavy Water Metabolic Labeling

被引:4
作者
Sadygov, Rovshan G. [1 ]
机构
[1] Univ Texas Med Branch, Dept Biochem & Mol Biol, Galveston, TX 77555 USA
关键词
protein turnover; LC– MS; rate constant; high resolution MS; TURNOVER; ENRICHMENT; SPECTRA; MODEL; RATES;
D O I
10.3390/ijms21217821
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Cellular proteins are continuously degraded and synthesized. The turnover of proteins is essential to many cellular functions. Combined with metabolic labeling using stable isotopes, LC-MS estimates proteome dynamics in high-throughput and on a large scale. Modern mass spectrometers allow a range of instrumental settings to optimize experimental output for specific research goals. One such setting which affects the results for dynamic proteome studies is the mass resolution. The resolution is vital for distinguishing target species from co-eluting contaminants with close mass-to-charge ratios. However, for estimations of proteome dynamics from metabolic labeling with stable isotopes, the spectral accuracy is highly important. Studies examining the effects of increased mass resolutions (in modern mass spectrometers) on the proteome turnover output and accuracy have been lacking. Here, we use a publicly available heavy water labeling and mass spectral data sets of murine serum proteome (acquired on Orbitrap Fusion and Agilent 6530 QToF) to analyze the effect of mass resolution of the Orbitrap mass analyzer on the proteome dynamics estimation. Increased mass resolution affected the spectral accuracy and the number acquired tandem mass spectra.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 38 条
[1]   Improved Sensitivity for Protein Turnover Quantification by Monitoring Immonium Ion Isotopologue Abundance [J].
Angel, Thomas E. ;
Naylor, Bradley C. ;
Price, John C. ;
Evans, Christopher ;
Szapacs, Matthew .
ANALYTICAL CHEMISTRY, 2019, 91 (15) :9732-9740
[2]   Heavy water labeling of DNA for measurement of cell proliferation and recruitment during primary murine lymph node responses against model antigens [J].
Busch, Robert ;
Siah, Iche M. ;
Gee, Tracy A. ;
Hellerstein, Marc K. .
JOURNAL OF IMMUNOLOGICAL METHODS, 2008, 337 (01) :24-34
[3]   Measurement of protein turnover rates by heavy water labeling of nonessential amino acids [J].
Busch, Robert ;
Kim, Yoo-Kyeong ;
Neese, Richard A. ;
Schade-Serin, Valerie ;
Collins, Michelle ;
Awada, Mohamad ;
Gardner, James L. ;
Beysen, Carine ;
Marino, Michael E. ;
Misell, Lisa M. ;
Hellerstein, Marc K. .
BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2006, 1760 (05) :730-744
[4]   A LIMITED MEMORY ALGORITHM FOR BOUND CONSTRAINED OPTIMIZATION [J].
BYRD, RH ;
LU, PH ;
NOCEDAL, J ;
ZHU, CY .
SIAM JOURNAL ON SCIENTIFIC COMPUTING, 1995, 16 (05) :1190-1208
[5]   Proteome Dynamics: Revisiting Turnover with a Global Perspective [J].
Claydon, Amy J. ;
Beynon, Robert .
MOLECULAR & CELLULAR PROTEOMICS, 2012, 11 (12) :1551-1565
[6]   Comparing DNA enrichment of proliferating cells following administration of different stable isotopes of heavy water [J].
Farthing, Don E. ;
Buxbaum, Nataliya P. ;
Lucas, Philip J. ;
Maglakelidze, Natella ;
Oliver, Brittany ;
Wang, Jiun ;
Hu, Kevin ;
Castro, Ehydel ;
Bare, Catherine V. ;
Gress, Ronald E. .
SCIENTIFIC REPORTS, 2017, 7
[7]   Precisely measured protein lifetimes in the mouse brain reveal differences across tissues and subcellular fractions [J].
Fornasiero, Eugenio F. ;
Mandad, Sunit ;
Wildhagen, Hanna ;
Alevra, Mihai ;
Rammner, Burkhard ;
Keihani, Sarva ;
Opazo, Felipe ;
Urban, Inga ;
Ischebeck, Till ;
Sakib, M. Sadman ;
Fard, Maryam K. ;
Kirli, Koray ;
Centeno, Tonatiuh Pena ;
Vidal, Ramon O. ;
Rahman, Raza-Ur ;
Benito, Eva ;
Fischer, Andre ;
Dennerlein, Sven ;
Rehling, Peter ;
Feussner, Ivo ;
Bonn, Stefan ;
Simons, Mikael ;
Urlaub, Henning ;
Rizzoli, Silvio O. .
NATURE COMMUNICATIONS, 2018, 9
[8]   The application of 2H2O to measure skeletal muscle protein synthesis [J].
Gasier, Heath G. ;
Fluckey, James D. ;
Previs, Stephen F. .
NUTRITION & METABOLISM, 2010, 7
[9]   High-Throughput Measurement of Lipid Turnover Rates Using Partial Metabolic Heavy Water Labeling [J].
Goh, Byoungsook ;
Kim, Jinwoo ;
Seo, Seungwoo ;
Kim, Tae-Young .
ANALYTICAL CHEMISTRY, 2018, 90 (11) :6509-6518
[10]   Increased serotransferrin and ceruloplasmin turnover in diet-controlled patients with type 2 diabetes [J].
Golizeh, Makan ;
Lee, Kwangwon ;
Ilchenko, Serguei ;
Osme, Abdullah ;
Bena, James ;
Sadygov, Rovshan G. ;
Kashyap, Sangeeta R. ;
Kasumov, Takhar .
FREE RADICAL BIOLOGY AND MEDICINE, 2017, 113 :461-469