Potential missing steps for a wide use of dried matrix spots in biomedical analysis

被引:13
作者
Deglon, Julien [1 ]
Leuthold, Luc Alexis [2 ]
Thomas, Aurelien [3 ]
机构
[1] Univ Hosp Geneva, Univ Ctr Legal Med, Toxicol Unit, CURML, CH-1211 Geneva, Switzerland
[2] Novartis Inst Biomed Res, DMPK, Adv Bioanalyt & Automat, Basel, Switzerland
[3] Univ Lausanne, Toxicol Unit, CURML, Lausanne, Switzerland
关键词
BLOOD SPOT; REGULATED BIOANALYSIS; QUANTITATIVE BIOANALYSIS; EBF RECOMMENDATION; ONLINE DESORPTION; PLASMA SPOTS; DBS; HEMATOCRIT; QUANTIFICATION; PERSPECTIVES;
D O I
10.4155/bio.15.166
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microsampling, mainly as DBS, has been significantly expanded in the biomedical and pharmaceutical communities in the last 10 years. In parallel, technology and methodology have evolved to overcome some of the issues associated with this sampling procedure. Despite the continuous developments and interest, only a few validated and routinely implemented clinical applications have arisen beyond the initial inborn screening. Based on the latest developments in this field, this perspective aims to discuss some of the missing steps (i.e., the habits to change, the Health Authorities acceptance and the shift for dried plasma generation), which may turn the current use of microsampling into an established and standard procedure in clinical and pharmaceutical analysis.
引用
收藏
页码:2375 / 2385
页数:11
相关论文
共 44 条
[31]   Dried blood spots: Concepts, present status, and future perspectives in bioanalysis [J].
Sharma, Abhisheak ;
Jaiswal, Swati ;
Shukla, Mahendra ;
Lal, Jawahar .
DRUG TESTING AND ANALYSIS, 2014, 6 (05) :399-414
[32]   Dried blood spot sampling for quantitative bioanalysis: time for a revolution? [J].
Spooner, Neil .
BIOANALYSIS, 2010, 2 (11) :1781-1781
[33]  
Tanna S, 2014, BIOANALYSIS, V6, P2825, DOI [10.4155/BIO.14.189, 10.4155/bio.14.189]
[34]   High-Throughput Phospholipidic Fingerprinting by Online Desorption of Dried Spots and Quadrupole-Linear Ion Trap Mass Spectrometry: Evaluation of Atherosclerosis Biomarkers in Mouse Plasma [J].
Thomas, Aurelien ;
Deglon, Julien ;
Lenglet, Sebastien ;
Mach, Francois ;
Mangin, Patrice ;
Wolfender, Jean-Luc ;
Steffens, Sabine ;
Staub, Christian .
ANALYTICAL CHEMISTRY, 2010, 82 (15) :6687-6694
[35]   Extraction and analysis of carnitine and acylcarnitines by electrospray ionization tandem mass spectrometry directly from dried blood and plasma spots using a novel autosampler [J].
Thompson, J. Will ;
Zhang, Haoyue ;
Smith, Peter ;
Hillman, Steven ;
Moseley, M. Arthur ;
Millington, David S. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (21) :2548-2554
[36]   Tiered approach revisited: introducing stage-appropriate or assay-appropriate scientific validation [J].
Timmerman, Philip .
BIOANALYSIS, 2014, 6 (05) :599-604
[37]   Update of the EBF recommendation for the use of DBS in regulated bioanalysis integrating the conclusions from the EBF DBS-microsampling consortium [J].
Timmerman, Philip ;
White, Steve ;
Cobb, Zoe ;
de Vries, Ronald ;
Thomas, Elizabeth ;
van Baar, Ben .
BIOANALYSIS, 2013, 5 (17) :2129-2136
[38]  
Timmerman P, 2013, BIOANALYSIS, V5, P139, DOI [10.4155/bio.12.267, 10.4155/BIO.12.267]
[39]  
Timmerman P, 2011, BIOANALYSIS, V3, P1567, DOI [10.4155/BIO.11.132, 10.4155/bio.11.132]
[40]  
Viswanathan CT, 2012, BIOANALYSIS, V4, P2763, DOI [10.4155/BIO.12.266, 10.4155/bio.12.266]