Exergoeconomic comparison of double effect and combined ejector-double effect absorption refrigeration systems

被引:130
作者
Farshi, L. Garousi [1 ]
Mahmoudi, S. M. S. [1 ]
Rosen, M. A. [2 ]
机构
[1] Univ Tabriz, Fac Mech Engn, Tabriz, Iran
[2] Univ Ontario, Fac Engn & Appl Sci, Inst Technol, Oshawa, ON L1H 7K4, Canada
关键词
Exergoeconomics; Double effect absorption refrigeration; Ejector; Product cost; Thermoeconomic variables; THERMOECONOMIC ANALYSIS; OPTIMIZATION; PERFORMANCE;
D O I
10.1016/j.apenergy.2012.11.022
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
At a particular temperature range, heat sources are not hot enough to drive lithium bromide double effect absorption refrigeration systems efficiently and are too hot to be used for the single effect systems because of the risk of crystallization. A combined ejector-double effect absorption cycle is a good choice to make effective use of heat sources at this temperature range for refrigeration purposes. In this study, detailed exergoeconomic analyses are performed for series flow double effect and combined ejector double effect systems in order to investigate and compare the influence of various operating parameters on investment costs of the overall systems and product cost flow rates. In addition, the proportion of component costs in the overall systems costs and exergoeconomic results are obtained. The results show that the combined cycle operates more economically compared to the double effect system. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:700 / 711
页数:12
相关论文
共 21 条
[1]  
[Anonymous], 2011, CHEM ENG-NEW YORK, P72
[2]   Theoretical analysis of LiBr/H2O absorption refrigeration systems [J].
Arora, Akhilesh ;
Kaushik, S. C. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (15) :1321-1340
[3]  
Bejan A, 1996, THERMAL DESIGN OPTIM
[4]   Solar-powered cooling systems: Technical and economic analysis on industrial refrigeration and air-conditioning applications [J].
Desideri, Umberto ;
Proietti, Stefania ;
Sdringola, Paolo .
APPLIED ENERGY, 2009, 86 (09) :1376-1386
[5]   A comparative study of the performance characteristics of double-effect absorption refrigeration systems [J].
Farshi, L. Garousi ;
Mahmoudi, S. M. Seyed ;
Rosen, M. A. ;
Yari, M. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2012, 36 (02) :182-192
[6]   Use of low grade heat sources in combined ejector-double effect absorption refrigeration systems [J].
Farshi, Leili Garousi ;
Mahmoudi, S. M. Seyed ;
Rosen, Marc A. ;
Yari, Morteza .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2012, 226 (A5) :607-622
[7]  
Howell RH, 1998, PRINCIPLES HVAC ASHR
[8]   A 1-D analysis of ejector performance [J].
Huang, BJ ;
Chang, JM ;
Wang, CP ;
Petrenko, VA .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (05) :354-364
[9]   Thermo-economical analysis between new absorption-ejector hybrid refrigeration system and small double-effect absorption system [J].
Jiang, LB ;
Gu, ZL ;
Feng, X ;
Li, Y .
APPLIED THERMAL ENGINEERING, 2002, 22 (09) :1027-1036
[10]  
Klein S., 2005, ENG EQUATION SOLVER