Reliability of digital measurement methods on the marginal fit of fixed prostheses: A systematic review and meta-analysis of in vitro studies

被引:13
作者
Mai, Hai Yen [1 ]
Lee, Won Kee [2 ]
Kwon, Tae-Geon [3 ]
Lee, Du-Hyeong
机构
[1] Kyungpook Natl Univ, Sch Dent, Dept Prosthodont, Daegu, South Korea
[2] Kyungpook Natl Univ, Sch Dent, Dept Med Informat, Daegu, South Korea
[3] Kyungpook Natl Univ, Inst Translat Res Dent, Dept Oral & Maxillofacial Surg, Sch Dent, Daegu, South Korea
基金
新加坡国家研究基金会;
关键词
DENTAL PROSTHESES; SINGLE CROWNS; RESTORATIONS; ADAPTATION; VALIDATION; PRECISION; CAST; 2D; 3D;
D O I
10.1016/j.prosdent.2020.04.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Digital methods have been increasingly used to evaluate the fit of prostheses, but the accuracy of digital methodology has not been fully clarified. Purpose. The purpose of this systematic review and meta-analysis was to assess the reliability of digital measurement methods for evaluating the marginal fit of fixed dental prostheses (FDPs) and to identify the potential factors that can influence the accuracy of the measurement methods. Material and methods. The differences between digital and conventional measurement methods were analyzed by searching PubMed, Scopus, Web of Science, and Google Scholar databases for studies reporting the marginal fit of FDPs. The agreement of data collection among the reviewers was confirmed by the Cohen kappa coefficient, and the MINORS scale was used to rate the quality of the included studies. The heterogeneity among the studies was evaluated, and meta-analyses with global and subgroup analyses were performed. Results. Ten in vitro studies were selected according to the eligibility criteria with substantial interreader concordance (kappa=0.88). The standard mean difference of the meta-analysis for marginal discrepancy was 0.12 mu m (95% confidence interval: -0.12 to 0.35), indicating that no statistically significant differences were found in the marginal discrepancies observed with digital and conventional methods (P=.343). The subgroup analysis for alloy-based prostheses was not significantly different, nor between the material and measurement methods (P=.060). Conclusions. Digital methods appear to be reliable as an alternative to conventional methods for evaluating the marginal fit of FDPs. To confirm the results of this study and to identify the influencing factors on the accuracy of digital measurement methods, further controlled laboratory and clinical studies are needed.
引用
收藏
页码:350.e1 / 350.e11
页数:11
相关论文
共 44 条
[1]   3D and 2D Marginal Fit of Pressed and CAD/CAM Lithium Disilicate Crowns Made from Digital and Conventional Impressions [J].
Anadioti, Evanthia ;
Aquilino, Steven A. ;
Gratton, David G. ;
Holloway, Julie A. ;
Denry, Isabelle ;
Thomas, Geb W. ;
Qian, Fang .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (08) :610-617
[2]  
Bluma Elina, 2016, Stomatologija, V18, P112
[3]   A systematic review of CAD/CAM fit restoration evaluations [J].
Boitelle, P. ;
Mawussi, B. ;
Tapie, L. ;
Fromentin, O. .
JOURNAL OF ORAL REHABILITATION, 2014, 41 (11) :853-874
[4]  
Boitelle P, 2018, J PROSTHET DENT, V119, P75, DOI 10.1016/j.prosdent.2017.01.026
[5]  
Borenstein M., 2009, INTRO META ANAL, P311, DOI DOI 10.1002/9780470743386.CH34
[6]   Effect of Misfit of Cement-Retained Implant Single Crowns on Crestal Bone Changes [J].
Chen, Chun-Jung ;
Papaspyridakos, Panos ;
Guze, Kevin ;
Singh, Medha ;
Weber, Hans-Peter ;
Gallucci, German O. .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2013, 26 (02) :135-137
[7]  
Contrepois M, 2013, J PROSTHET DENT, V110, P447, DOI 10.1016/j.prosdent.2013.08.003
[8]  
Cunali Rafael Schlögel, 2017, Braz. Dent. J., V28, P467, DOI 10.1590/0103-6440201601531
[9]   Micro-CT evaluation of marginal and internal fit of cemented polymer infiltrated ceramic network material crowns manufactured after conventional and digital impressions [J].
Dauti, Rinet ;
Cvikl, Barbara ;
Lilaj, Bledar ;
Heimel, Patrick ;
Moritz, Andreas ;
Schedle, Andreas .
JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (01) :40-46
[10]   EXPERIMENTAL STRESS ANALYSIS OF DENTAL RESTORATIONS .3. CONCEPT OF GEOMETRY OF PROXIMAL MARGINS [J].
ELEBRASHI, MK ;
CRAIG, RG ;
PEYTON, FA .
JOURNAL OF PROSTHETIC DENTISTRY, 1969, 22 (03) :333-+