An electrokinetic cell model for analysis and optimization of electroosmotic microfluidic pumps

被引:12
作者
Piyasena, ME
Lopez, GP
Petsev, DN [1 ]
机构
[1] Univ New Mexico, Dept Chem & Nucl Engn, Albuquerque, NM 87131 USA
[2] Univ New Mexico, Dept Chem, Albuquerque, NM 87131 USA
基金
美国国家科学基金会;
关键词
electrokinetic; electroosmotic pump; microfluidic;
D O I
10.1016/j.snb.2005.03.069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple bead packed electroosmotic microfluidic pump has been designed and fabricated. Such pumps can generate pressure of over 10 atm and are amenable to integration with other microfluidic components, thus making these pumps highly attractive for lab-on-a chip devices. An analytical theoretical description for such packed beads micropumps is presented. It is based on the cell models for hydrodynamic and electrokinetic transport in complex porous media. The theoretical analysis yields useful relationships between the parameters of the pump (bead size, capillary size, electrokinetic c-potential) and its performance (pressure and flow) rate and hence, provides guidelines for optimal design for desired properties. We found that the generated pressure strongly depends on the bead size. It also increases with the bead zeta-potential, volume fraction and capillary length. The flow rate on the other hand is not an explicit function of the bead size, but depends on the overall capillary cross-sectional area. This allows for independently varying of these two essential properties. The theory was tested against model experiments, thus proving its validity, range of applicability and limitations. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:461 / 467
页数:7
相关论文
共 32 条
[1]  
[Anonymous], SURFACE COLLOID SCI
[2]  
BORKOVSKAYA Y, 1982, THESIS I COLLOID CHE
[3]   Biomolecular recognition on well-characterized beads packed in microfluidic channels [J].
Buranda, T ;
Huang, JM ;
Perez-Luna, VH ;
Schreyer, B ;
Sklar, LA ;
Lopez, GP .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1149-+
[4]   Formation of natural pH gradients in a microfluidic device under flow conditions: Model and experimental validation [J].
Cabrera, CR ;
Finlayson, B ;
Yager, P .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :658-666
[5]   Generating high-pressure sub-microliter flow rate in packed microchannel by electroosmotic force: potential application in microfluidic systems [J].
Chen, LX ;
Ma, JP ;
Tan, F ;
Guan, YF .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 88 (03) :260-265
[6]   Study of an electroosmotic pump for liquid delivery and its application in capillary column liquid chromatography [J].
Chen, LX ;
Ma, JP ;
Guan, YF .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1028 (02) :219-226
[7]   An electroosmotic pump for packed capillary liquid chromatography [J].
Chen, LX ;
Ma, JP ;
Guan, YF .
MICROCHEMICAL JOURNAL, 2003, 75 (01) :15-21
[8]   Dynamic electrophoretic mobility in concentrated dispersed systems. Cell model [J].
Dukhin, AS ;
Shilov, V ;
Borkovskaya, Y .
LANGMUIR, 1999, 15 (10) :3452-3457
[9]  
FENTON K, UNPUB
[10]  
GRIGOROV ON, 1957, COLLOID J RUSS ACAD+, V19, P406