Ct-based finite element models can be used to estimate experimentally measured failure loads in the proximal femur

被引:102
作者
Koivumaki, Janne E. M. [1 ]
Thevenot, Jerome [1 ]
Pulkkinen, Pasi [1 ]
Kuhn, Volker [2 ,3 ]
Link, Thomas M. [4 ]
Eckstein, Felix [3 ,5 ]
Jamsa, Timo [1 ,6 ]
机构
[1] Univ Oulu, Dept Med Technol, FI-90014 Oulu, Finland
[2] Med Univ, Innsbruck, Austria
[3] LMU Munchen, Munich, Germany
[4] Univ Calif San Francisco, San Francisco, CA 94143 USA
[5] Paracelcus Med Univ, Salzburg, Austria
[6] Oulu Univ Hosp, Dept Diagnost Radiol, Oulu, Finland
基金
芬兰科学院;
关键词
Hip fracture; Finite element; Bone biomechanics; Bone strength; Femur; FEMORAL FRACTURE LOAD; TROCHANTERIC HIP-FRACTURES; MECHANICAL-PROPERTIES; CORTICAL BONE; PREDICTION; STRENGTH; FALL; DENSITY; STRAIN; LOCATION;
D O I
10.1016/j.bone.2012.01.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objective of this experimental finite element (FE) study was to assess the accuracy of a simulation model estimate of the experimentally measured fracture load of the proximal femur in a sideways fall. Sixty-one formalin-fixed cadaver femora (41 female and 20 male) aged 55-100 years (an average of 80 years) were scanned with a multi-detector CT scanner and were mechanically tested for failure in a sideways fall loading configuration. Twenty-one of these femurs were used for training purposes, and 40 femurs were used for validation purposes. The training set FE models were used to establish the strain threshold for the element failure criteria. Bi-linear elastoplastic FE analysis was performed based on the CT images. The validation set was used to estimate the fracture loads. The Drucker-Prager criterion was applied to determine the yielding and the maximum principal stress criteria and the minimum principal strain criteria for element failure in tension and in compression, respectively. The estimated fracture load values were highly correlated with the experimental data (r = 0.931; p<0.001). The slope was 0.929, with an intercept of 258 N, which was not significantly different from 1 and 0, respectively. The study shows that it is possible to estimate the fracture load with relatively high accuracy in a sideways fall configuration by using the CT-based FE method. This method may therefore be applied for studying the biomechanical mechanisms of hip fractures. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:824 / 829
页数:6
相关论文
共 42 条
  • [1] Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
    Bayraktar, HH
    Morgan, EF
    Niebur, GL
    Morris, GE
    Wong, EK
    Keaveny, TM
    [J]. JOURNAL OF BIOMECHANICS, 2004, 37 (01) : 27 - 35
  • [2] Prediction of the strength and fracture location of the femoral neck by CT-based finite-element method: a preliminary study on patients with hip fracture
    Bessho, M
    Ohnishi, I
    Okazaki, H
    Sato, W
    Kominami, H
    Matsunaga, S
    Nakamura, K
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2004, 9 (06) : 545 - 550
  • [3] Prediction of strength and strain of the proximal femur by a CT-based finite element method
    Bessho, Masahiko
    Ohnishi, Isao
    Matsuyama, Juntaro
    Matsumoto, Takuya
    Imai, Kazuhiro
    Nakamura, Kozo
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (08) : 1745 - 1753
  • [4] Prediction of proximal femur strength using a CT-based nonlinear finite element method: Differences in predicted fracture load and site with changing load and boundary conditions
    Bessho, Masahiko
    Ohnishi, Isao
    Matsumoto, Takuya
    Ohashi, Satoru
    Matsuyama, Juntaro
    Tobita, Kenji
    Kaneko, Masako
    Nakamura, Kozo
    [J]. BONE, 2009, 45 (02) : 226 - 231
  • [5] AGING OF BONE TISSUE - MECHANICAL-PROPERTIES
    BURSTEIN, AH
    REILLY, DT
    MARTENS, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (01) : 82 - 86
  • [6] The Role of Cortical Shell and Trabecular Fabric in Finite Element Analysis of the Human Vertebral Body
    Chevalier, Yan
    Pahr, Dieter
    Zysset, Philippe K.
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (11):
  • [7] Femoral strength is better predicted by finite element models than QCT and DXA
    Cody, DD
    Gross, GJ
    Hou, FJ
    Spencer, HJ
    Goldstein, SA
    Fyhrie, DP
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (10) : 1013 - 1020
  • [8] FALL FREQUENCY AND CHARACTERISTICS AND THE RISK OF HIP-FRACTURES
    CUMMING, RG
    KLINEBERG, RJ
    [J]. JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1994, 42 (07) : 774 - 778
  • [9] During sideways falls proximal femur fractures initiate in the superolateral cortex: Evidence from high-speed video of simulated fractures
    de Bakker, Peter M.
    Manske, Sarah L.
    Ebacher, Vincent
    Oxland, Thomas R.
    Cripton, Peter A.
    Guy, Pierre
    [J]. JOURNAL OF BIOMECHANICS, 2009, 42 (12) : 1917 - 1925
  • [10] Robust QCT/FEA Models of Proximal Femur Stiffness and Fracture Load During a Sideways Fall on the Hip
    Dragomir-Daescu, Dan
    Den Buijs, Jorn Op
    McEligot, Sean
    Dai, Yifei
    Entwistle, Rachel C.
    Salas, Christina
    Melton, L. Joseph, III
    Bennet, Kevin E.
    Khosla, Sundeep
    Amin, Shreyasee
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (02) : 742 - 755