摘要
We have microfabricated a flow-through biochip for the analysis of single base mutations in genomic DNA using two different materials: (1) a polycarbonate (PC) chip for performing a primary polymerase chain reaction (PCR) followed by an allele-specific ligation detection reaction (LDR) and (2) a poly(methyl methacrylate) (PMMA) chip for the detection of the LDR products using a universal array platform. The operation of the device was demonstrated by detecting low-abundant DNA mutations in gene fragments (K-ras) that carry point mutations with high diagnostic value for colorectal cancers. The PC microchip was used for sequential PCR/LDR in a continuous-flow format, in which the following three steps were carried out: (1) exponential amplification of gene fragments from genomic DNA; (2) mixing of the resultant PCR product with a LDR mixture via a Y-shaped passive micromixer and (3) ligation of two primers only when the particular mutation was present in the genomic DNA. A PMMA chip was employed as the microarray device, where zip code sequences (24-mer), which were complementary to sequences present on the discriminating primer, were micro-printed into fluidic channels embossed into the PMMA substrate. We successfully demonstrate the ability to detect one mutant DNA in 80 normal sequences with the integrated microfluidic device. The PCR/LDR/hybridization assay using the microchips performed the entire assay at a relatively fast processing speed: 18.7 min for PCR, 8.1 min for LDR, 5 min for hybridization, 10 min for washing and 2.6 min for fluorescence scanning (total processing time = ca. 50 min) with an order of magnitude reduction in reagents compared to bench-top formats. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1915 / 1923
页数:9
相关论文
共 14 条
[11]   Highly Sensitive Multiplex Detection of Molecular Biomarkers Using Hybridization Chain Reaction in an Encoded Particle Microfluidic Platform [J].
Rutten, Iene ;
Daems, Devin ;
Leirs, Karen ;
Lammertyn, Jeroen .
BIOSENSORS-BASEL, 2023, 13 (01)
[12]   Discriminative detection of low-abundance point mutations using a PCR/ligase detection reaction/capillary gel electrophoresis method and fluorescence dual-channel monitoring [J].
Hamada, Mariko ;
Shimase, Koji ;
Tsukagoshi, Kazuhiko ;
Hashimoto, Masahiko .
ELECTROPHORESIS, 2014, 35 (08) :1204-1210
[13]   Prenatal Detection of Beta-Thalassemia CD17 (A→T) Mutation by Polymerase Chain Reaction/Ligase Detection Reaction/Capillary Electrophoresis for Fetal DNA in Maternal Plasma - A Case Report [J].
Yi, Ping ;
Chen, Zhuqin ;
Yu, Lili ;
Zheng, Yingru ;
Xie, Haichang ;
Zheng, Xiuhui ;
Liu, Qiang ;
Han, Jian ;
Li, Li .
FETAL DIAGNOSIS AND THERAPY, 2010, 27 (01) :25-31
[14]   Visual Detection of Canine Monocytic Ehrlichiosis Using Polymerase Chain Reaction-Based Lateral Flow Biosensors [J].
Sumpavong, Peeravit ;
Kaewmongkol, Sarawan ;
Kaewmongkol, Gunn .
ANIMALS, 2025, 15 (05)