On-line capillary electrophoresis/microelectrospray ionization-tandem mass spectrometry using an ion trap storage/time-of-flight mass spectrometer with SWIFT technology

被引:20
|
作者
Jin, XY
Kim, J
Parus, S
Lubman, DM [1 ]
Zand, R
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biol Chem, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Div Biophys Res, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac990221r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a system capable of the speed required for on-line capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) of tryptic digests is described. The ion trap storage/reflectron time-of-flight (IT/reTOF) mass spectrometer is used as a nonscanning detector for rapid CE separation, where the peptides are ionized on-line using electrospray ionization (ESI). The ESI produced ions are stored in the ion trap and de pulse injected into the reTOF-MS at a rate sufficient to maintain the separation achieved by CE. Using methodology generated by software and hardware developed in our lab, we can produce SWIFT (Stored Waveform Inverse Fourier Transform) ion isolation and TICKLE activation/fragmentation voltage waveforms to generate MS/MS at a rate as high as 10 Hz so that the MS/MS spectra can be optimized on even a 1-2 s eluting peak. In CE separations performed on tryptic digests of dogfish myelin basic protein (MBP) where eluting peaks 4-8 s wide are observed, it is demonstrated that an acquisition rate of 4 Hz provides >20 spectra/peak and is more than sufficient to provide optimized MS/MS spectra of each of the eluting peaks in the electropherogram. The detailed structural analysis of dogfish MBP including several posttranslational modifications using CE-MS and CE-MS/MS is demonstrated using this method with <10 fmol of material consumed.
引用
收藏
页码:3591 / 3597
页数:7
相关论文
共 50 条
  • [21] Development of a tandem time-of-flight mass spectrometer with an electrospray ionization ion source
    Nagao, Hirofumi
    Shimma, Shuichi
    Hayakawa, Shigeo
    Awazu, Kunio
    Toyoda, Michisato
    JOURNAL OF MASS SPECTROMETRY, 2010, 45 (08): : 937 - 943
  • [22] Design of a time-of-flight mass spectrometer as a detector for capillary electrophoresis
    Lazar, IM
    Xin, BM
    Lee, ML
    Lee, ED
    Rockwood, AL
    Fabbi, JC
    Lee, HG
    ANALYTICAL CHEMISTRY, 1997, 69 (16) : 3205 - 3211
  • [23] Use of an ion trap storage/reflectron time-of-flight mass spectrometer as a rapid and sensitive detector for capillary electrophoresis in protein digest analysis
    Wu, JT
    Qian, MG
    Li, MX
    Liu, L
    Lubman, DM
    ANALYTICAL CHEMISTRY, 1996, 68 (19) : 3388 - 3396
  • [24] On the performance of an on-line time-of-flight mass spectrometer for aerosols
    Weiss, M
    Verheijen, PJT
    Marijnissen, JCM
    Scarlett, B
    JOURNAL OF AEROSOL SCIENCE, 1997, 28 (01) : 159 - 171
  • [25] Development and characterization of an electrospray ionization ion trap linear time-of-flight mass spectrometer
    Purves, RW
    Li, L
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (10) : 1085 - 1093
  • [26] Identification of eicosasaccharide structures in glycosaminoglycan mixtures from human decorin by on-line sheathless capillary electrophoresis/electrospray ionization quadrupole time-of-flight tandem mass spectrometry
    Zamfir, AD
    Seidler, DG
    Kresse, H
    Peter-Katalinic, J
    GLYCOBIOLOGY, 2002, 12 (10) : 678 - 678
  • [27] Tandem Mass Spectrometry on a Miniaturized Laser Desorption Time-of-Flight Mass Spectrometer
    Li, Xiang
    Cornish, Timothy
    Ecelberger, Scott
    Getty, Stephanie A.
    Brinckerhoff, William B.
    2016 IEEE AEROSPACE CONFERENCE, 2016,
  • [28] Optimization of a quadrupole ion storage trap as a source for time-of-flight mass spectrometry
    Dangi, Beni B.
    Ervin, Kent M.
    JOURNAL OF MASS SPECTROMETRY, 2012, 47 (01): : 41 - 48
  • [29] Electronics of an ion trap with integrated time-of-flight mass spectrometer
    Schneider, Christian
    Schowalter, Steven J.
    Yu, Peter
    Hudson, Eric R.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2016, 394 : 1 - 8
  • [30] Planar Multipole Ion Trap/Time-of-Flight Mass Spectrometer
    Lorenz, Ulrich J.
    Rizzo, Thomas R.
    ANALYTICAL CHEMISTRY, 2011, 83 (20) : 7895 - 7901