Design of a Portable, Intrinsically Safe Multichannel Acquisition System for High-Resolution, Real-Time Processing HD-sEMG

被引:19
作者
Barone, Umberto [1 ]
Merletti, Roberto [1 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, LISiN Lab, I-10129 Turin, Italy
关键词
Biopotential amplifier; EMG; multichannel acquisition; plastic optical fiber (POF); wearable equipment; LOW-NOISE; BIOELECTRIC EVENTS; AMPLIFIER;
D O I
10.1109/TBME.2013.2252346
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A compact and portable system for real-time, multichannel, HD-sEMG acquisition is presented. The device is based on a modular, multiboard approach for scalability and to optimize power consumption for battery operating mode. The proposed modular approach allows us to configure the number of sEMG channels from 64 to 424. A plastic-optical-fiber-based 10/100 Ethernet link is implemented on a field-programmable gate array (FPGA)-based board for real-time, safety data transmission toward a personal computer or laptop for data storage and offline analysis. The high-performance A/D conversion stage, based on 24-bit ADC, allows us to automatically serialize the samples and transmits them on a single SPI bus connecting a sequence of up to 14 ADC chips in chain mode. The prototype is configured to work with 64 channels and a sample frequency of 2.441 ksps (derived from 25-MHz clock source), corresponding to a real data throughput of 3Mbps. The prototype was assembled to demonstrate the available features (e.g., scalability) and evaluate the expected performances. The analog front end board could be dynamically configured to acquire sEMG signals in monopolar or single differential mode by means of FPGA I/O interface. The system can acquire continuously 64 channels for up to 5 h with a lightweight battery pack of 7.5 Vdc/2200 mAh. A PC-based application was also developed, by means of the open source Qt Development Kit from Nokia, for prototype characterization, sEMG measurements, and real-time visualization of 2-D maps.
引用
收藏
页码:2242 / 2252
页数:11
相关论文
共 38 条
[1]  
Amer, 2001, J ELECT CHINA, V18, P242
[2]  
Amer, 2001, J ELECT CHINA, V18, P242
[3]  
[Anonymous], 2009, SBAS367F BURR BROWN
[4]  
[Anonymous], 2009, DBOS458F TEX INSTR
[5]  
[Anonymous], 2008, SBOS445B TEX INSTR
[6]  
[Anonymous], 2002, Spectrum and spectral density estimation by the Discrete Fourier transform
[7]  
[Anonymous], 2009, EUROPEAN RECOMMENDAT
[8]   Systematic design of programmable operational amplifiers with noise-power trade-off [J].
Bronskowski, C. ;
Schroeder, D. .
IET CIRCUITS DEVICES & SYSTEMS, 2007, 1 (01) :41-48
[9]  
Carrillo J. M., 1998, 1998 IEEE International Conference on Electronics, Circuits and Systems. Surfing the Waves of Science and Technology (Cat. No.98EX196), P363, DOI 10.1109/ICECS.1998.814900
[10]   Surface-Mounted Dry Electrode and Analog-Front-End Systems for Physiological Signal Measurements [J].
Chang, C. W. ;
Chiou, J. C. .
2009 IEEE/NIH LIFE SCIENCE SYSTEMS AND APPLICATIONS WORKSHOP, 2009, :108-111