Predictors of Prolonged Hemodynamic Compromise After Valve Deployment During Transcatheter Aortic Valve Implantation

被引:7
作者
Iritakenishi, Takeshi [1 ]
Kamibayashi, Takahiko [1 ]
Torikai, Kei [2 ]
Maeda, Koichi [2 ]
Kuratani, Toru [2 ]
Sawa, Yoshiki [2 ]
Fujino, Yuji [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Anesthesiol & Intens Care Med, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Cardiovasc Surg, Suita, Osaka 5650871, Japan
关键词
rapid pacing; transcatheter aortic valve implantation; aortic stenosis; mixed venous oxygen saturation; VENOUS OXYGEN-SATURATION; DYSFUNCTION; MANAGEMENT; CONSENSUS; CATHETER; OXIMETRY; IMPACT; GOAL;
D O I
10.1053/j.jvca.2015.02.019
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To identify the risk factors of prolonged hemodynamic compromise caused by rapid pacing for valve deployment during transcatheter aortic valve implantation. Design: A retrospective study. Setting: Academic hospital. Participants: Forty-seven patients with severe aortic stenosis who underwent transcatheter aortic valve implantation.. Interventions: The time after the end of rapid pacing until systolic arterial pressure and SvO(2) recovery (systolic arterial pressure >90 mmHg and SvO(2) >65%) was defined as "the hemodynamic recovery time" and was measured from online anesthetic charts. The total study population was divided into 2 groups according to the recovery time (third quartile in all patients; 33 and 14 patients in the early and delayed recovery groups, respectively). Subsequently, the factors associated with prolonged hemodynamic compromise after rapid pacing for valve deployment were identified by univariate and multivariate analyses. Measurements and Main Results: Multivariate analysis identified left ventricular end-diastolic diameter (odds ratio, 0.774; 95% confidence interval, 0.608-0.915) and SvO(2) (odds ratio, 0.748; 95% confidence interval, 0.590-0.868) as independent factors associated with prolonged hemodynamic compromise after rapid pacing for valve deployment. Conclusions: SvO(2) and left ventricular end-diastolic diameter were found to be significant independent predictors of prolonged hemodynamic compromise immediately after rapid pacing for valve deployment during transcatheter aortic valve implantation. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:868 / 874
页数:7
相关论文
共 50 条
  • [31] Antithrombotic therapy after transcatheter aortic valve implantation
    Greco, Antonio
    Spagnolo, Marco
    Capodanno, Davide
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (06) : 499 - 513
  • [32] Prosthetic Valve Escaping During Transcatheter Aortic Valve Implantation
    Furukawa, Nobuyuki
    Scholtz, Werner
    Scholtz, Smita
    Faber, Lothar
    Ensminger, Stephan
    Gummert, Jan
    Boergermann, Jochen
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2015, 10 (06) : 425 - 427
  • [33] Transcatheter Aortic Valve Implantation in Mixed Aortic Valve Disease: A Multicenter Study
    Guddeti, Raviteja R.
    Gill, Gauravpal S.
    Parekh, Jai D.
    Jhand, Aravdeep S.
    Walters, Ryan W.
    Panaich, Sidakpal S.
    Goldsweig, Andrew M.
    Alla, Venkata Mahesh
    AMERICAN JOURNAL OF CARDIOLOGY, 2023, 203 : 394 - 402
  • [34] Conduction abnormalities after transcatheter aortic valve implantation
    Karyofillis, Panagiotis
    Kostopoulou, Anna
    Thomopoulou, Sofia
    Habibi, Martha
    Livanis, Efthimios
    Karavolias, George
    Voudris, Vassilis
    JOURNAL OF GERIATRIC CARDIOLOGY, 2018, 15 (01) : 105 - 112
  • [35] Antithrombotic Therapy After Transcatheter Aortic Valve Implantation
    Marisol Lugo, Leslie
    Romaguera, Rafael
    Antoni Gomez-Hospital, Joan
    Luis Ferreiro, Jose
    EUROPEAN CARDIOLOGY REVIEW, 2020, 15 : 54 - 61
  • [36] Computational hemodynamic indices to identify Transcatheter Aortic Valve Implantation degeneration
    Crugnola, Luca
    Vergara, Christian
    Fusini, Laura
    Fumagalli, Ivan
    Luraghi, Giulia
    Redaelli, Alberto
    Pontone, Gianluca
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2025, 259
  • [37] The incidence, predictors, and prognosis of acute kidney injury after transcatheter aortic valve implantation
    Attard, Stephanie
    Buttigieg, Jesmar
    Galea, Stephanie
    Mintoff, Malcolm
    Farrugia, Emanuel
    Cassar, Andrew
    CLINICAL NEPHROLOGY, 2018, 90 (06) : 373 - 379
  • [38] Incidence, Timing, and Predictors of Valve Hemodynamic Deterioration After Transcatheter Aortic Valve Replacement Multicenter Registry
    Del Trigo, Maria
    Munoz-Garcia, Antonio J.
    Wijeysundera, Harindra C.
    Nombela-Franco, Luis
    Cheema, Asim N.
    Gutierrez, Enrique
    Serra, Vicenc
    Kefer, Joelle
    Amat-Santos, Ignacio J.
    Benitez, Luis M.
    Mewa, Jumana
    Jimenez-Quevedo, Pilar
    Alnasser, Sami
    Garcia del Blanco, Bruno
    Dager, Antonio
    Abdul-Jawad Altisent, Omar
    Puri, Rishi
    Campelo-Parada, Francisco
    Dahou, Abdellaziz
    Paradis, Jean-Michel
    Dumont, Eric
    Pibarot, Philippe
    Rodes-Cabau, Josep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (06) : 644 - 655
  • [39] The Importance of Echocardiography in Transcatheter Aortic Valve Implantation
    Bilen, Emine
    Sari, Cenk
    Durmaz, Tahir
    Keles, Telat
    Bayram, Nihal A.
    Akcay, Murat
    Ayhan, Huseyin M.
    Bozkurt, Engin
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (01): : 101 - 110
  • [40] Aortic regurgitation after transcatheter aortic valve implantation
    Costopoulos, Charis
    Naganuma, Toru
    Latib, Azeem
    Colombo, Antonio
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2013, 11 (09) : 1089 - 1092