Predictors of Prolonged Hemodynamic Compromise After Valve Deployment During Transcatheter Aortic Valve Implantation

被引:6
|
作者
Iritakenishi, Takeshi [1 ]
Kamibayashi, Takahiko [1 ]
Torikai, Kei [2 ]
Maeda, Koichi [2 ]
Kuratani, Toru [2 ]
Sawa, Yoshiki [2 ]
Fujino, Yuji [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Anesthesiol & Intens Care Med, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Cardiovasc Surg, Suita, Osaka 5650871, Japan
关键词
rapid pacing; transcatheter aortic valve implantation; aortic stenosis; mixed venous oxygen saturation; VENOUS OXYGEN-SATURATION; DYSFUNCTION; MANAGEMENT; CONSENSUS; CATHETER; OXIMETRY; IMPACT; GOAL;
D O I
10.1053/j.jvca.2015.02.019
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To identify the risk factors of prolonged hemodynamic compromise caused by rapid pacing for valve deployment during transcatheter aortic valve implantation. Design: A retrospective study. Setting: Academic hospital. Participants: Forty-seven patients with severe aortic stenosis who underwent transcatheter aortic valve implantation.. Interventions: The time after the end of rapid pacing until systolic arterial pressure and SvO(2) recovery (systolic arterial pressure >90 mmHg and SvO(2) >65%) was defined as "the hemodynamic recovery time" and was measured from online anesthetic charts. The total study population was divided into 2 groups according to the recovery time (third quartile in all patients; 33 and 14 patients in the early and delayed recovery groups, respectively). Subsequently, the factors associated with prolonged hemodynamic compromise after rapid pacing for valve deployment were identified by univariate and multivariate analyses. Measurements and Main Results: Multivariate analysis identified left ventricular end-diastolic diameter (odds ratio, 0.774; 95% confidence interval, 0.608-0.915) and SvO(2) (odds ratio, 0.748; 95% confidence interval, 0.590-0.868) as independent factors associated with prolonged hemodynamic compromise after rapid pacing for valve deployment. Conclusions: SvO(2) and left ventricular end-diastolic diameter were found to be significant independent predictors of prolonged hemodynamic compromise immediately after rapid pacing for valve deployment during transcatheter aortic valve implantation. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:868 / 874
页数:7
相关论文
共 50 条
  • [21] Relationships Between Intraoperative Hemodynamic Parameters and Delayed Hemodynamic Recovery After Valve Deployment in Transcatheter Aortic Valve Replacement
    Kameyama, Akiyo
    Ito, Hisakatsu
    Hibi, Daisuke
    Matsui, Sakiyo
    Kawakami, Masaaki
    Ueno, Hiroshi
    Fukahara, Kazuaki
    Yamazaki, Mitsuaki
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (04) : 920 - 926
  • [22] Hemodynamic Performance of Self-Expandable Transcatheter Aortic Valve Replacement Systems During Valve Deployment
    Alperi, Alberto
    Moris, Cesar
    del Valle, Raquel
    Pascual, Isaac
    Antuna, Paula
    Almendarez, Marcel
    Hernandez-Vaquero, Daniel
    Betanzos, Jose Luis
    Rodes-Cabau, Josep
    Avanzas, Pablo
    JOURNAL OF INVASIVE CARDIOLOGY, 2024, 36 (08):
  • [23] Challenges in transcatheter valve treatment: aortic regurgitation after transcatheter aortic valve implantation
    Sinning, Jan-Malte
    Werner, Nikos
    Nickenig, Georg
    Grube, Eberhard
    EUROINTERVENTION, 2013, 9 : S72 - S76
  • [24] Predictors of In-Hospital Mortality after Transcatheter Aortic Valve Implantation
    Krittanawong, Chayakrit
    Kumar, Anirudh
    Wang, Zhen
    Johnson, Kipp W.
    Rastogi, Ujjwal
    Narasimhan, Bharat
    Kaplin, Scott
    Virk, Hafeez Ul Hassan
    Baber, Usman
    Tang, Wilson
    Lansky, Alexandra J.
    Stone, Gregg W.
    AMERICAN JOURNAL OF CARDIOLOGY, 2020, 125 (02): : 251 - 257
  • [25] Anatomical predictors of conduction damage after transcatheter implantation of the aortic valve
    Tretter, Justin T.
    Mori, Shumpei
    Anderson, Robert H.
    Taylor, Michael D.
    Ollberding, Nicholas
    Truong, Vien
    Choo, Joseph
    Kereiakes, Dean
    Mazur, Wojciech
    OPEN HEART, 2019, 6 (01):
  • [26] Incidence, predictors and impact of bleeding after transcatheter aortic valve implantation
    Borz, B.
    Durand, E.
    Godin, M.
    Tron, C.
    Litzler, P-Y.
    Bessou, J. -P.
    Canville, A.
    Cribier, A.
    Eltchaninoff, H.
    EUROPEAN HEART JOURNAL, 2012, 33 : 719 - 719
  • [27] PREDICTORS OF EARLY DISCHARGE HOME AFTER TRANSCATHETER AORTIC VALVE IMPLANTATION
    Mallikethi-Reddy, Sagar
    Trehan, Naveen
    Kundumadam, Shanker
    Sood, Aditya
    Sudhakar, Rajeev
    Rubenfire, Melvyn
    Khan, Mazhar
    Afonso, Luis
    Grines, Cindy
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 69 (11) : 1244 - 1244
  • [28] Predictors of improvement in diastolic function after transcatheter aortic valve implantation
    Maayan K.
    Simon B.
    Yan T.
    Yigal A.
    Ofer H.
    Eyal B.-A.
    Eran L.-R.
    Yaron A.
    Gad K.
    Shmuel B.
    Ariel F.
    Journal of Echocardiography, 2014, 12 (1) : 17 - 23
  • [29] Transcatheter aortic valve-in-valve implantation in degenerative rapid deployment bioprostheses
    Landes, Uri
    Dvir, Danny
    Schoels, Wolfgang
    Tron, Christophe
    Ensminger, Stephan
    Simonato, Matheus
    Schaefer, Ulrich
    Bunc, Matjaz
    Aldea, Gabriel
    Cerillo, Alfredo
    Windecker, Stephan
    Marzocchi, Antonio
    Andreas, Martin
    Amabile, Nicolas
    Webb, John
    Kornowski, Ran
    EUROINTERVENTION, 2019, 15 (01) : 37 - +
  • [30] Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement
    Hoyt, Matthew J.
    Hathaway, Jessica
    Palmer, Roseanne
    Beach, Michael
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (05) : 1162 - 1166