Comparison of Invasive and Noninvasive Assessment of Aortic Stenosis Severity in the Elderly

被引:18
作者
Gertz, Zachary M. [1 ]
Raina, Amresh [2 ]
O'Donnell, William [1 ]
McCauley, Brian D. [1 ]
Shellenberger, Charlene [1 ]
Kolansky, Daniel M. [1 ]
Wilensky, Robert L. [1 ]
Forfia, Paul R. [1 ]
Herrmann, Howard C. [1 ]
机构
[1] Childrens Hosp Philadelphia, Div Cardiovasc Med, Philadelphia, PA 19104 USA
[2] Allegheny Gen Hosp, Sect Heart Failure Transplant & Pulm Hypertens, Pittsburgh, PA 15212 USA
关键词
aortic stenosis; aortic valve area; aortic valve replacement; elderly; OUTFLOW TRACT ECCENTRICITY; VALVE AREA DETERMINATION; CARDIAC-OUTPUT; THERMODILUTION METHOD; OXYGEN-CONSUMPTION; CONTINUITY EQUATION; GORLIN FORMULA; FICK; ECHOCARDIOGRAPHY; CATHETERIZATION;
D O I
10.1161/CIRCINTERVENTIONS.111.967836
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Aortic valve area (AVA) in aortic stenosis (AS) can be assessed noninvasively or invasively, typically with similar results. These techniques have not been validated in elderly patients, where common assumptions make them most prone to error. Accurate assessment of AVA is crucial to determine which patients are appropriate candidates for aortic valve replacement. Methods and Results-Fifty elderly patients (mean 86 years, 46% female) referred for cardiac catheterization to evaluate AS also underwent transthoracic echocardiography within 24 hours. To minimize assumptions all patients had 3-dimensional echocardiography (Echo-3D), and at catheterization using directly measured oxygen consumption (Cath-mVo(2)) and thermodilution cardiac output (Cath-TD). Correlation between Cath-mVo(2) and Echo-3D AVA was poor (r=0.41). Cath-TD AVA had a moderate correlation with Echo-3D AVA (r=0.59). Cath-mVo(2) (AVA=0.69 cm(2)) and Cath-TD (AVA=0.66 cm(2)) underestimated AVA compared with Echo-3D (AVA = 0.76 cm(2); P=0.08 for comparison with Cath-mVo2; P=0.001 for Cath-TD). Compared with Echo-3D, the sensitivity and specificity for determining critical disease (AVA <0.8 cm(2)) were 81% and 42% for Cath-mVo2, and 97% and 53% for Cath-TD. The only independent predictor of the difference between noninvasive and invasive AVA was stroke volume index (P<0.01). Resistance, a less flow-dependent measure, showed a stronger correlation between Echo-3D and Cath-mVo(2) (r=0.69), and Echo-3D and Cath-TD (r=0.77). Conclusions-Standard techniques of AVA assessment for AS show poor correlation in elderly patients, with frequent misclassification of critical AS. Less flow-dependent measures, such as resistance, should be considered to ensure that only appropriate patients are treated with aortic valve replacement. (Circ Cardiovasc Interv. 2012;5:406-414.)
引用
收藏
页码:406 / 414
页数:9
相关论文
共 33 条
  • [1] Evaluation of the significance of a transvalvular catheter aortic valve gradient in aortic stenosis: A direct hemodynamic and Doppler echocardiographic study
    Adele, C
    Vaitkus, PT
    Tischler, MD
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (04) : 513 - &
  • [2] Outcomes of cardiac surgery in patients age ≥80 years:: Results from the National Cardiovascular Network
    Alexander, KP
    Anstrom, KJ
    Muhlbaier, LH
    Grosswald, RD
    Smith, PK
    Jones, RH
    Peterson, ED
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (03) : 731 - 738
  • [3] Bonow Robert O, 2008, Circulation, V118, pe523, DOI 10.1161/CIRCULATIONAHA.108.190748
  • [4] DEPENDENCE OF GORLIN FORMULA AND CONTINUITY EQUATION VALVE AREAS ON TRANSVALVULAR VOLUME FLOW-RATE IN VALVULAR AORTIC-STENOSIS
    BURWASH, IG
    THOMAS, DD
    SADAHIRO, M
    PEARLMAN, AS
    VERRIER, ED
    THOMAS, R
    KRAFT, CD
    OTTO, CM
    [J]. CIRCULATION, 1994, 89 (02) : 827 - 835
  • [5] Burwash IG, 2000, CAN J CARDIOL, V16, P985
  • [6] AORTIC-VALVE RESISTANCE AS AN ADJUNCT TO THE GORLIN FORMULA IN ASSESSING THE SEVERITY OF AORTIC-STENOSIS IN SYMPTOMATIC PATIENTS
    CANNON, JD
    ZILE, MR
    CRAWFORD, FA
    CARABELLO, BA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (07) : 1517 - 1523
  • [7] HYDRAULIC ESTIMATION OF STENOTIC ORIFICE AREA - A CORRECTION OF THE GORLIN FORMULA
    CANNON, SR
    RICHARDS, KL
    CRAWFORD, M
    [J]. CIRCULATION, 1985, 71 (06) : 1170 - 1178
  • [8] THERMODILUTION METHOD FOR MEASURING CARDIAC-OUTPUT
    CONWAY, J
    LUNDJOHANSEN, P
    [J]. EUROPEAN HEART JOURNAL, 1990, 11 : 17 - 20
  • [9] 601 octogenarians undergoing cardiac surgery: Outcome and comparison with younger age groups
    Craver, JM
    Puskas, JD
    Weintraub, WW
    Shen, Y
    Guyton, RA
    Gott, JP
    Jones, EL
    [J]. ANNALS OF THORACIC SURGERY, 1999, 67 (04) : 1104 - 1110
  • [10] OXYGEN-CONSUMPTION IN ADULT PATIENTS DURING CARDIAC-CATHETERIZATION
    DEHMER, GJ
    FIRTH, BG
    HILLIS, LD
    [J]. CLINICAL CARDIOLOGY, 1982, 5 (08) : 436 - 440