Thermodynamic analysis and optimization of a balanced-type single-stage NH3-H2O absorption-resorption heat pump cycle for residential heating application

被引:29
作者
Jia, Teng [1 ,2 ]
Dai, Enqian [1 ,2 ]
Dai, Yanjun [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
[2] MOE, Engn Res Ctr Solar Power & Refrigerat, Beijing, Peoples R China
关键词
Ammonia-water; Balanced-type absorption-resorption; Heat pump; Solar thermal; Residential heating; SOLAR COLLECTORS; ENERGY-STORAGE; SYSTEM; DRIVEN; PERFORMANCE;
D O I
10.1016/j.energy.2019.01.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
Ammonia-water absorption-resorption heat pump (ARHP) is a promising technology in efficient utilization of low-temperature heat for residential heating application. This paper proposes a balanced-type single-stage ARHP cycle based on the unbalanced ARHP cycle by eliminating the rectifier and depending on only one solution circulation pump. The proposed cycle can achieve internal mass and species conservation by changing the ammonia-water solution concentration difference at different pressure levels. A mathematical model is developed to obtain feasible high pressure/low pressure (P-H/P-L) pairs to enable the cycle. The cycle's coefficient of performance (COP) at different PH/PL pair values is investigated. The maximum COP is 1.51 and the corresponding heat supply temperature reaches 43.4 degrees C when P-H/P-L pair value is 1.50/0.48 MPa and heat source temperature is 95 degrees C. The maximum heat supply temperature can reach 53.4 degrees C and the minimum ambient air temperature to effect the cycle is 5.8 degrees C. Other parameters like heat output/inputs, solution circulation ratios, and absorption and desorption concentration gradients in the absorbers and generators are studied. Inner pressure (difference), COP and heat source temperature demand have been compared with those of the conventional absorption heat pump (AHP) cycle and the unbalanced ARHP cycle. The results revealed that the proposed cycle could work at lower heat source temperature (above 82 degrees C) and within wider heat source temperature range than the conventional AHP cycle, indicating that the proposed cycle is potential in efficient utilization of commonly used solar collectors for space heating. In addition, the proposed cycle could be operated at higher COP values and lower inner pressure differences than the unbalanced ARHP cycle. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:120 / 134
页数:15
相关论文
共 36 条
[31]   Development of bubble absorption refrigeration technology: A review [J].
Wu, Xi ;
Xu, Shiming ;
Jiang, Mengnan .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 82 :3468-3482
[32]   Experimental investigation on a solar assisted heat pump desalination system with humidification-dehumidification [J].
Xu, H. ;
Zhao, Y. ;
Jia, T. ;
Dai, Y. J. .
DESALINATION, 2018, 437 :89-99
[33]   Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions [J].
Zambolin, E. ;
Del Col, D. .
SOLAR ENERGY, 2010, 84 (08) :1382-1396
[34]   Advances in vapor compression air source heat pump system in cold regions: A review [J].
Zhang, Long ;
Jiang, Yiqiang ;
Dong, Jiankai ;
Yao, Yang .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 81 :353-365
[35]   Theoretical and experimental investigations on the changing regularity of the extreme point of the temperature difference between zeotropic mixtures and heat transfer fluid [J].
Zheng, Nan ;
Song, Weidong ;
Zhao, Li .
ENERGY, 2013, 55 :541-552
[36]   Experimental investigation of a solar driven direct-expansion heat pump system employing the novel PV/micro-channels-evaporator modules [J].
Zhou, Jinzhi ;
Zhao, Xudong ;
Ma, Xiaoli ;
Qiu, Zhongzhu ;
Ji, Jie ;
Du, Zhenyu ;
Yu, Min .
APPLIED ENERGY, 2016, 178 :484-495