Quantitative determination of heparin levels in serum with microtiter plate-format optode

被引:11
作者
Kim, SB [1 ]
Kang, TY [1 ]
Cha, GS [1 ]
Nam, H [1 ]
机构
[1] Kwangwoon Univ, Dept Chem, Chem Sensor Res Grp, Seoul 139701, South Korea
关键词
microtiter plate-format optode; heparin; protamine; polymer-to-plasticizer ratio; ion-selective optode;
D O I
10.1016/j.aca.2005.10.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new assay method has been developed for the quantitative determination of heparin in serum using a microtiter plate-format optode (MPO). Heparin and proton in physiological sample are favorably co-extracted into the solvent polymeric optode membrane containing both cationic lipophilic additive, tridodecylmethyl ammonium chloride (TDMAC), and proton-selective ionophore, 3-hydroxy-4-(4-nitrophenylazo)-phenyloctadecanoate (ETH 2412), resulting in the absorbance change of the membrane to varying heparin levels. The optimized MPO composition contains low polymer-to-plasticizer ratio compared to those of conventional ion-selective optodes or electrodes, i.e., poly(vinyl chloride) (20.0)/dioctylsebacate (76.3)/ETH 2412 (1.7)/TDMAC (1.0) (wt.%): it resulted in a quantitative response to heparin from 0 to 15 unit/mL in serum with high sensitivity. The heparin-protamine titration on the MPO could provide rapid and precise determination of heparin. It was shown that the heparin levels in serum sample could be determined from the rate of absorbance change over time (Delta A/Delta t); this method was more effective than the direct absorbance measurement in minimizing the interferences from color and turbidity of serum samples. MPO has been developed as a high throughput and convenient disposable sensing device, and may find a wide application in the determination of polyions and charged macromolecules. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 17 条
[1]   Ionophore-based membrane electrodes: new analytical concepts and non-classical response mechanisms [J].
Bakker, E ;
Meyerhoff, ME .
ANALYTICA CHIMICA ACTA, 2000, 416 (02) :121-137
[2]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[3]   Optical detection of polycations via polymer film-modified microtiter plates: Response mechanism and bioanalytical applications [J].
Dai, S ;
Ye, QS ;
Wang, EJ ;
Meyerhoff, ME .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3142-3149
[4]   POLYMER MEMBRANE-BASED POLYION SENSORS - DEVELOPMENT, RESPONSE MECHANISM, AND BIOANALYTICAL APPLICATIONS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
WANG, EJ ;
YANG, VC ;
MEYERHOFF, ME .
ELECTROANALYSIS, 1995, 7 (09) :823-829
[5]   RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2250-2259
[6]   Polyionic drug-sensitive membrane electrodes: Principles and practice [J].
Fu, B ;
Yun, JH ;
Wahr, J ;
Meyerhoff, ME ;
Yang, VC .
ADVANCED DRUG DELIVERY REVIEWS, 1996, 21 (03) :215-223
[7]   Development of an ion-channel sensor for heparin detection [J].
Gadzekpo, VPY ;
Bühlmann, P ;
Xiao, KP ;
Aoki, H ;
Umezawa, Y .
ANALYTICA CHIMICA ACTA, 2000, 411 (1-2) :163-173
[8]   Microtiter plate-format optode [J].
Kim, SB ;
Cho, HC ;
Cha, GS ;
Nam, H .
ANALYTICAL CHEMISTRY, 1998, 70 (22) :4860-4863
[9]   Determination of protamine using microtiter plate-format optodes [J].
Kim, SB ;
Kang, TY ;
Cho, HC ;
Choi, MH ;
Cha, GS ;
Nam, H .
ANALYTICA CHIMICA ACTA, 2001, 439 (01) :47-53
[10]   Heparin-induced thrombocytopenia in children: 12 new cases and review of the literature [J].
Klenner, AF ;
Lubenow, N ;
Raschke, R ;
Greinacher, A .
THROMBOSIS AND HAEMOSTASIS, 2004, 91 (04) :719-724