Rate of Legionella pneumophila colonization in hospital hot water network after time flow taps installation

被引:20
作者
Totaro, M. [1 ]
Valentini, P. [1 ]
Costa, A. L. [1 ]
Giorgi, S. [1 ]
Casini, B. [1 ]
Baggiani, A. [1 ]
机构
[1] Univ Pisa, Dept Translat Res & New Technol Med & Surg, Via S Zeno 35-39, I-56127 Pisa, Italy
关键词
Legionella; Time flow taps; Hospital water network; Chlorine dioxide;
D O I
10.1016/j.jhin.2017.08.021
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
In hospital water systems legionellae may be resistant to disinfectants in pipework, which is a problem particularly in areas where there is low flow or stagnation of water. We evaluated legionella colonization of a water network of an Italian hospital after time flow taps (TFTs) installation in proximity to dead legs. The water volume flushed was 64 L/day from May 2016, and 192 L/day from December 2016. Before TFTs installation, Legionella pneumophila sg2-14 was detected in all points (4 x 10(4) +/- 3.1 x 10(4) cfu/L). All sites remained positive (2.9 x 10(4) +/- 1.9 x 10(4) cfu/L) through November 2016. From December 2016 legionella persisted in one point only (2 x 10(2) to 6.8 x 10(3) cfu/L). TFTs with chemical disinfection may reduce legionella colonization associated with dead legs. (C) 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:60 / 63
页数:4
相关论文
共 8 条
  • [1] Water quality modeling in the dead end sections of drinking water distribution networks
    Abokifa, Ahmed A.
    Yang, Y. Jeffrey
    Lo, Cynthia S.
    Biswas, Pratim
    [J]. WATER RESEARCH, 2016, 89 : 107 - 117
  • [2] Long-Term Effects of Hospital Water Network Disinfection on Legionella and Other Waterborne Bacteria in an Italian University Hospital
    Casini, Beatrice
    Buzzigoli, Andrea
    Cristina, Maria Luisa
    Spagnolo, Anna Maria
    Del Giudice, Pietro
    Brusaferro, Silvio
    Poscia, Andrea
    Moscato, Umberto
    Valentini, Paola
    Baggiani, Angelo
    Privitera, Gaetano
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2014, 35 (03) : 293 - 299
  • [3] European Centre for Disease Prevention and Control, 2015, LEG DIS EUR
  • [4] Grayman W.M., 2006, WATER DISTRIBUTION S, P1
  • [5] Interactive Effects of Corrosion, Copper, and Chloramines on Legionella and Mycobacteria in Hot Water Plumbing
    Rhoads, William J.
    Pruden, Amy
    Edwards, Marc K.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (12) : 7065 - 7075
  • [6] Storey MV, 2004, SCAND J INFECT DIS, V36, P656, DOI 10.1080/00365540410020785
  • [7] Superior Institute of Health, 2015, LIN GUID PREV CONTR
  • [8] Experimental comparison of point-of-use filters for drinking water ultrafiltration
    Totaro, M.
    Valentini, P.
    Casini, B.
    Miccoli, M.
    Costa, A. L.
    Baggiani, A.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2017, 96 (02) : 172 - 176