Partial Volume Correction in Arterial Spin Labeling Using a Look-Locker Sequence

被引:26
作者
Petr, Jan [1 ]
Schramm, Georg [1 ]
Hofheinz, Frank [1 ]
Langner, Jens [1 ]
van den Hoff, Joerg [1 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, Inst Radiopharm, PET Ctr, Dresden, Germany
关键词
partial volume effect; look-locker; ASL; arterial spin labeling; cerebral blood flow; CEREBRAL PERFUSION; BRAIN MRI; REPRODUCIBILITY; INVERSION; SEGMENTATION; WATER; AGE;
D O I
10.1002/mrm.24601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposePartial volume (PV) effects are caused by limited spatial resolution and significantly affect cerebral blood flow investigations with arterial spin labeling. Therefore, accurate PV correction (PVC) procedures are required. PVC is commonly based on PV maps obtained from segmented high-resolution T-1-weighted images. Segmentation of these images is error-prone, and it can be difficult to coregister these images accurately with the single-shot ASL images such as those created by echo-planar imaging (EPI). In this paper, an alternative method for PV map generation is proposed. MethodsThe Look-Locker EPI (LL-EPI) acquisition is used for analyzing the T-1-recovery curve and for subsequent PV map generation. The new method was evaluated in five healthy volunteers (mean age 30 3.7 years). ResultsBy applying a linear regression method for PVC, a 12% decrease in regression error was reached with the new method. ConclusionPV maps extraction from LL-EPI is a viable, possibly superior alternative to the standard approach based on segmentation of high-resolution T-1-weighted images. Magn Reson Med 70:1535-1543, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1535 / 1543
页数:9
相关论文
共 38 条
[1]  
Ahlgren A, 2011, P 28 ANN M ESMRMB LE, P554
[2]  
[Anonymous], 2010, R LANG ENV STAT COMP
[3]   Unified segmentation [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2005, 26 (03) :839-851
[4]   Separating Function From Structure in Perfusion Imaging of the Aging Brain [J].
Asllani, Iris ;
Habeck, Christian ;
Borogovac, Ajna ;
Brown, Truman R. ;
Brickman, Adam M. ;
Stern, Yaakov .
HUMAN BRAIN MAPPING, 2009, 30 (09) :2927-2935
[5]   Regression Algorithm Correcting for Partial Volume Effects in Arterial Spin Labeling MRI [J].
Asllani, Iris ;
Borogovac, Ajna ;
Brown, Truman R. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) :1362-1371
[6]   Age dependence of cerebral perfusion assessed by magnetic resonance continuous arterial spin labeling [J].
Biagi, Laura ;
Abbruzzese, Arturo ;
Bianchi, Maria Cristina ;
Alsop, David C. ;
Del Guerra, Alberto ;
Tosetti, Michela .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (04) :696-702
[7]   Mapping brain function using a 30-day interval between baseline and activation: a novel arterial spin labeling fMRI approach [J].
Borogovac, Ajna ;
Habeck, Christian ;
Small, Scott A. ;
Asllani, Iris .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2010, 30 (10) :1721-1733
[8]   Comparison of pulsed arterial spin labeling encoding schemes and absolute perfusion quantification [J].
Cavusoglu, Mustafa ;
Pfeuffer, Josef ;
Ugurbil, Kamil ;
Uludag, Kamil .
MAGNETIC RESONANCE IMAGING, 2009, 27 (08) :1039-1045
[9]   Partial Volume Correction of Multiple Inversion Time Arterial Spin Labeling MRI Data [J].
Chappell, M. A. ;
Groves, A. R. ;
MacIntosh, B. J. ;
Donahue, M. J. ;
Jezzard, P. ;
Woolrich, M. W. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) :1173-1183
[10]   Test-Retest Reliability of Arterial Spin Labeling With Common Labeling Strategies [J].
Chen, Yufen ;
Wang, Danny J. J. ;
Detre, John A. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) :940-949