Simultaneous Determination of Copper(II) and Cobalt(II) Ions, Copper(II) and Manganese(II) Ions in Drinking Water Using Indicator Test Tubes Based on Carboxylic Cation-Exchangers

被引:2
作者
Zharkova, V. V. [1 ]
Bobkova, L. A. [1 ]
机构
[1] Natl Res Tomsk State Univ, Dept Chem, Tomsk 634050, Russia
关键词
carboxylic cation exchangers; test determination of Mn(II); Co(II); and Cu(II) ions; indicator tubes;
D O I
10.1134/S1061934819050125
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We investigated a possibility of determining two metal ions (Cu2+ and Co2+, Cu2+ and Mn2+) in a single water sample using an indicator test tube filled with a carboxylic cation exchanger of a macrocellular (KB-2E-10, KB-2E-16) or a macroporous (Tokem-250) structure. Under dynamic conditions, the separation of the chromatographic zones of colored Cu2+ and Co2+ ions was achieved in the presence of water macro components, that is, Ca2+ and Mg2+ ions. An analytical reagent, formaldoxime, was used to determine colorless Mn2+ ions. The performance characteristics of the developed procedures are determined. The lowest limit of detection for ions was obtained using a KB-2E-16 cation exchanger; it is 0.016 mg/L for Cu2+, 0.045mg/L for Co2+, and 0.003 mg/L for Mn2+. The proposed procedures were used to analyze real samples for the concentration of Co2+ and Cu2+ or Mn2+ and Cu2+ on their simultaneous presence. The accuracy of the results was evaluated by the standard addition method.
引用
收藏
页码:672 / 678
页数:7
相关论文
共 9 条
[1]  
[Anonymous], 2011, 214107401 SANPIN
[2]  
[Anonymous], 2011, 107401 SANPIN
[3]  
EGOROVA LS, 2008, IZV ALTAJSKOGO GOS U, V3, P57
[4]   Rapid determination of copper(I, II) ions using reagent indicator paper [J].
Gaiduk, O. V. ;
Pantaler, R. P. ;
Grebenyuk, N. N. ;
Ostrovskaya, V. M. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 64 (02) :201-205
[5]   Capabilities and Prospects of the Development of a Chromaticity Method in Analytical Chemistry [J].
Ivanov, V. M. ;
Monogarova, O. V. ;
Oskolok, K. V. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (10) :1165-1178
[6]   Using silica modified by poly(hexamethylene guanidine) and nitroso-R-salt for the preconcentration and determination of cobalt [J].
Losev, V. N. ;
Didukh, S. L. ;
Mukhina, A. N. ;
Trofimchuk, A. K. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (06) :677-684
[7]  
Losev VN, 2010, J SIB FED UNIV-CHEM, V3, P64
[8]  
Savvin S. B., 2000, RUSS CHEM REV, V69, P187, DOI DOI 10.1070/RC2000v069n03ABEH000538
[9]  
Tikhonova L.P., 2011, KHIM FIZ TEKHNOL POV, V2, P300