A prospective cohort study evaluating a novel colonoscopy platform featuring full-spectrum endoscopy

被引:54
作者
Gralnek, Ian Mark [1 ,3 ]
Segol, Ori [4 ]
Suissa, Alain [1 ,2 ]
Siersema, Peter D. [5 ]
Carr-Locke, David L. [6 ]
Halpern, Zamir [7 ,8 ]
Santo, Erwin [7 ,8 ]
Domanov, Svetlana [2 ]
机构
[1] Technion Israel Inst Technol, Dept Gastroenterol, Rambam Hlth Care Campus, Haifa, Israel
[2] Technion Israel Inst Technol, Elisha Hosp, Gastrointestinal Endoscopy Unit, Haifa, Israel
[3] Technion Israel Inst Technol, Rappaport Fac Med, Haifa, Israel
[4] Lady Davis Carmel Med Ctr, Haifa, Israel
[5] Univ Med Ctr, Dept Gastroenterol & Hepatol, Utrecht, Netherlands
[6] Beth Israel Deaconess Med Ctr, New York, NY 10003 USA
[7] Tel Aviv Univ, Tel Aviv Sourasky Med Ctr, Dept Gastroenterol, IL-69978 Tel Aviv, Israel
[8] Tel Aviv Univ, Sch Med, IL-69978 Tel Aviv, Israel
关键词
MISS-RATE; COLORECTAL-CANCER; ADENOMA DETECTION; WITHDRAWAL TIMES; SIMULATED POLYPS; IMPACT; RATES; RETROFLEXION; POLYPECTOMY; MULTICENTER;
D O I
10.1055/s-0033-1344395
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims: Although colonoscopy is the criterion standard for detecting colorectal adenomas and cancers, a significant percentage of adenomas are missed with this technique. We aimed to establish the feasibility, usability, and safety of a novel colonoscopy platform featuring full-spectrum endoscopy (FUSE). Patients and methods: This was a prospective, single-center pilot and feasibility study. In total, 50 individuals, ages 18 - 70 years, underwent colonoscopy featuring FUSE (up to 330 degrees field of view) for colorectal cancer screening, polyp surveillance, or diagnostic evaluation. Study end points included success of cecal intubation, time to cecal intubation, withdrawal time, total procedure time, success of therapeutic interventions, adverse events, and endoscopists' subjective evaluation of FUSE. Results: Cecal intubation was achieved in 50/50 individuals (100 %). Time to cecum (minutes, mean +/- SD) was 3.1 +/- 1.5 minutes, withdrawal time 12.7 +/- 4.4 minutes, and total procedure time 15.3 +/- 4.6 minutes. In 22/50 cases (44 %), 26 therapeutic interventions were performed: 19 (73.1 %) biopsies and 7 (26.9 %) polypectomies. No acute or delayed adverse events were observed. Patient satisfaction and endoscopist subjective evaluation were high. Conclusions: A colonoscopy platform featuring full-spectrum endoscopy appears feasible, usable, and safe. These results represent an important advance in colonoscopy imaging technology and should be further pursued in comparative human studies.
引用
收藏
页码:697 / 702
页数:6
相关论文
共 23 条
  • [11] Use of colonoscopy to screen asymptomatic adults for colorectal cancer
    Lieberman, DA
    Weiss, DG
    Bond, JH
    Ahnen, DJ
    Garewal, H
    Chejfec, G
    Harford, WV
    Provenzale, D
    Sontag, S
    Schnell, T
    Campbell, DR
    Durbin, TE
    Nelson, DB
    Ewing, SL
    Triadafilopoulos, G
    Ramirez, FC
    Lee, JG
    Collins, JF
    Fennerty, B
    Johnston, TK
    Corless, CT
    McQuaid, KR
    Sampliner, RE
    Morales, TG
    Fass, R
    Smith, R
    Maheshwari, Y
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (03) : 162 - 168
  • [12] Guidelines for Colonoscopy Surveillance After Screening and Polypectomy: A Consensus Update by the US Multi-Society Task Force on Colorectal Cancer
    Lieberman, David A.
    Rex, Douglas K.
    Winawer, Sidney J.
    Giardiello, Francis M.
    Johnson, David A.
    Levin, Theodore R.
    [J]. GASTROENTEROLOGY, 2012, 143 (03) : 844 - 857
  • [13] Location of adenomas missed by optical colonoscopy
    Pickhardt, PJ
    Nugent, PA
    Mysliwiec, PA
    Choi, JR
    Schindler, WR
    [J]. ANNALS OF INTERNAL MEDICINE, 2004, 141 (05) : 352 - 359
  • [14] Wide angle colonoscopy with a prototype instrument: Impact on miss rates and efficiency as determined by back-to-back colonoscopies
    Rex, DK
    Chadalawada, V
    Helper, DJ
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2003, 98 (09) : 2000 - 2005
  • [15] Accessing proximal aspects of folds and flexures during colonoscopy: Impact of a pediatric colonoscope with a short bending section
    Rex, DK
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2003, 98 (07) : 1504 - 1507
  • [16] Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies
    Rex, DK
    Cutler, CS
    Lemmel, GT
    Rahmani, EY
    Clark, DW
    Helper, DJ
    Lehman, GA
    Mark, DG
    [J]. GASTROENTEROLOGY, 1997, 112 (01) : 24 - 28
  • [17] The endoscopic cap that can (with videos)
    Sanchez-Yague, Andres
    Kaltenbach, Tonya
    Yamamoto, Hironori
    Anglemyer, Andrew
    Inoue, Haruhiro
    Soetikno, Roy
    [J]. GASTROINTESTINAL ENDOSCOPY, 2012, 76 (01) : 169 - +
  • [18] A pilot study to assess the safety and efficacy of the Third Eye Retrograde auxiliary imaging system during colonoscopy
    Triadafilopoulos, G.
    Li, J.
    [J]. ENDOSCOPY, 2008, 40 (06) : 478 - 482
  • [19] A novel retrograde-viewing auxiliary imaging device (Third Eye Retroscope) improves the detection of simulated polyps in anatomic models of the colon
    Triadafilopoulos, George
    Watts, H. David
    Higgins, Jack
    Van Dam, Jacques
    [J]. GASTROINTESTINAL ENDOSCOPY, 2007, 65 (01) : 139 - 144
  • [20] Polyp miss rate determined by tandem colonoscopy: A systematic review
    van Rijn, JC
    Reitsma, JB
    Stoker, J
    Bossuyt, PM
    van Deventer, SJ
    Dekker, E
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2006, 101 (02) : 343 - 350