Diagnostic accuracy of two software modalities for detection of caries lesions in digital radiographs from four dental systems

被引:9
|
作者
Hintze, H [1 ]
机构
[1] Univ Aarhus, Sch Dent, Dept Oral Radiol, Fac Hlth Sci, DK-8000 Aarhus C, Denmark
关键词
dental caries; radiography; dental; digital; ROC curve; diagnostic test;
D O I
10.1259/dmfr/50356588
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the caries diagnostic accuracy of two software modalities used in the assessment of digital radiographs obtained with four different dental systems, and to evaluate whether the software used for image assessment influenced the mutual comparison of those four dental systems relating to their caries diagnostic accuracy. Methods: Under in vitro and standardized conditions 122 teeth (with 228 unrestored approximal and 99 occlusal Surfaces) were radiographed in blocks of 3 test teeth and 2 non-test teeth using two storage phosphor plate systems: Digora (Soredex. Helsinki, Finland) and DenOptix (Gendex, Dentsply, Milan, Italy) and two charge coupled device (CCD)-based sensor systems: Dixi (Planmeca, Helsinki, Finland) and Sidexis (Sirona, Bensheim, Germany). The images were displayed and examined in two software modalities: their own dedicated software and a general software. Three observers examined all images for the presence of approximal enamel and dentine and occlusal dentine caries lesions using a 5-point confidence scale. The true presence of caries was validated by ground section histology. The diagnostic accuracy of the software modalities was expressed as ROC curve areas (A(z)) and differences between modalities were tested by paired t-test. Comparison of systems was analysed by post hoc t-test. Results: Results of approximal and occlusal surfaces assessed together revealed nearly identical mean A(z) with the two software modalities on images obtained with the Digora (A(z) = 0.71) and DenOptix (A(z) = 0.72) systems. On Dixi images the mean A(z) was 0.75 using the system's own software and 0.73 using the general software. On Sidexis images the corresponding mean A(z)s were 0.79 and 0.75. None of those differences were sionificant. Conclusion: No significant difference in caries diagnostic accuracy was found between two software modalities used for examination of digital radiographs obtained with four different digital systems, and the software modality did not influence the mutual rank of the four systems relating to their diagnostic accuracy.
引用
收藏
页码:78 / 82
页数:5
相关论文
共 36 条
  • [1] Accuracy of caries detection with four storage phosphor systems and E-speed radiographs
    Hintze, H
    Wenzel, A
    Frydenberg, M
    DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (03) : 170 - 175
  • [2] Effect of monitor display on detection of approximal caries lesions in digital radiographs
    Isidor, S.
    Faaborg-Andersen, M.
    Hintze, H.
    Kirkevang, L-L
    Frydenberg, M.
    Haiter-Neto, F.
    Wenzel, A.
    DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (08) : 537 - 541
  • [3] Diagnostic Accuracy of Digital and Conventional Radiography in the Detection of Non-Cavitated Approximal Dental Caries
    Abesi, Farida
    Mirshekar, Alireza
    Moudi, Ehsan
    Seyedmajidi, Maryam
    Haghanifar, Sina
    Haghighat, Nima
    Bijani, Ali
    IRANIAN JOURNAL OF RADIOLOGY, 2012, 9 (01) : 17 - 21
  • [4] Effect of noise on the compressibility and diagnostic accuracy for caries detection of digital bitewing radiographs
    Janhom, A
    van der Stelt, PF
    van Ginkel, FC
    Geraets, WGM
    DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (01) : 6 - 12
  • [5] Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions
    Haiter-Neto, F.
    Wenzel, A.
    Gotfredsen, E.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (01) : 18 - 22
  • [6] Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systems
    Hintze, H
    Wenzel, A
    DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (01) : 44 - 49
  • [7] Clinical Analysis of the Diagnostic Accuracy and Time of Execution of a Transillumination Caries Detection Method Compared to Bitewing Radiographs
    Pelliccioni, Gian Andrea
    Gatto, Maria Rosaria Antonella
    Bolognesi, Silvia
    Dal Fiume, Daniele
    Sebold, Maicon
    Breschi, Lorenzo
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (20)
  • [8] Accuracy of computer-automated caries detection in digital radiographs compared with human observers
    Wenzel, A
    Hintze, H
    Kold, LM
    Kold, S
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2002, 110 (03) : 199 - 203
  • [9] Radiographic detection of approximal caries: a comparison of dental films and digital imaging systems
    Syriopoulos, K
    Sanderink, GCH
    Velders, XL
    van der Stelt, PF
    DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (05) : 312 - 318
  • [10] Comparison of digital systems and conventional dental film for the detection of approximal enamel caries
    Pontual, A. A.
    de Melo, D. P.
    de Almeida, S. M.
    Boscolo, F. N.
    Haiter Neto, F.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (07) : 431 - 436