Efficient generation of volatile cadmium species using Ti(III) and Ti(IV) and application to determination of cadmium by cold vapor generation inductively coupled plasma mass spectrometry (CVG-ICP-MS)

被引:17
作者
Arslan, Zikri [1 ]
Yilmaz, Vedat [1 ,2 ]
Rose, LaKeysha [1 ]
机构
[1] Jackson State Univ, Dept Chem & Biochem, Jackson, MS 39217 USA
[2] Erciyes Univ, Dept Analyt Chem, Fac Pharm, TR-38039 Kayseri, Turkey
关键词
Cadmium; Chemical vapor generation; Titanium (III); Titanium (IV); Inductively coupled plasma mass spectrometry; ATOMIC-ABSORPTION-SPECTROMETRY; FORM ANION-EXCHANGER; FLUORESCENCE SPECTROMETRY; ENVIRONMENTAL-SAMPLES; HYDRIDE GENERATION; BORANE COMPLEXES; ROOM-TEMPERATURE; AQUEOUS-MEDIA; TETRAHYDROBORATE; EMISSION;
D O I
10.1016/j.microc.2015.06.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a highly efficient chemical vapor generation (CVG) approach is reported for determination of cadmium (Cd). Titanium (III) and titanium (IV) were investigated for the first time as catalytic additives along with thiourea, L-cysteine and potassium cyanide (KCN) for generation of volatile Cd species. Both Ti(III) and Ti(IV) provided the highest enhancement with KCN. The improvement with thiourea was marginal (ca. 2-fold), while L-cysteine enhanced signal slightly only with Ti(III) in H2SO4. Optimum CVG conditions were 4% (v/v) HCl + 0.03 M Ti(III) + 0.16 M KCN and 2% (v/v) HNO3 + 0.03 M Ti(IV) + 0.16 M KCN with a 3% (m/v) NaBH4 solution. The sensitivity was improved about 40-fold with Ti(III) and 35-fold with Ti(IV). A limit of detection (LOD) of 3.2 ng L-1 was achieved with Ti(III) by CVG-ICP-MS. The LOD with Ti(IV) was 6.4 ng L-1 which was limited by the blank signals in Ti(IV) solution. Experimental evidence indicated that Ti(III) and Ti(IV) enhanced Cd vapor generation catalytically; for best efficiency mixing prior to reaction with NaBH4 was critical. The method was highly robust against the effects of transition metal ions. No significant suppression was observed in the presence of Co(II), Cr(III), Cu(ll), Fe(III), Mn(II), Ni(II) and Zn(II) up to 1.0 mu g mL(-1). Among the hydride forming elements, no interference was observed from As(III) and Se(IV) at 0.5 mu g mL(-1) level. The depressive effects from Pb(II) and Sb(III) were not significant at 0.1 mu g mL(-1) while those from Bi(III) and Sn(II) were marginal. The procedures were validated with determination of Cd by CVG-ICP-MS in a number certified reference materials, including Nearshore seawater (CASS-4), Bone ash (SRM 1400), Dogfish liver (DOLT-4), Mussel tissue (SRM 2976) and Domestic Sludge (SRM 2781). (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:170 / 178
页数:9
相关论文
共 32 条
[1]   Vapor Generation Atomic Absorption Spectrometric Determination of Cadmium in Environmental Samples with In-Line Anion Exchange Separation [J].
Adeloju, Samuel B. ;
Zhang, Yanlin .
ANALYTICAL CHEMISTRY, 2009, 81 (11) :4249-4255
[2]   GENERATION OF A VOLATILE CADMIUM SPECIES IN AN ORGANIC MEDIUM [J].
CACHO, J ;
BELTRAN, I ;
NERIN, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) :661-663
[3]   Determination of As, Cd and Hg in emulsified vegetable oil by flow injection chemical vapour generation inductively coupled plasma mass spectrometry [J].
Chang, Yu-Tzu ;
Jiang, Shiuh-Jen .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (01) :140-144
[4]  
Chuachuad W, 2004, CAN J ANAL SCI SPECT, V49, P362
[5]   Determination of cadmium by flow injection atomic absorption spectrometry with cold vapor generation by a tetrahydroborate-form anion-exchanger [J].
Chuachuad, W ;
Tyson, JF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (04) :273-281
[6]   Chemical vapor generation for atomic spectrometry. A contribution to the comprehension of reaction mechanisms in the generation of volatile hydrides using borane complexes [J].
D'Ulivo, A ;
Baiocchi, C ;
Pitzalis, E ;
Onor, M ;
Zamboni, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (04) :471-486
[7]   Chemical vapor generation by tetrahydroborate(III) and other borane complexes in aqueous media - A critical discussion of fundamental processes and mechanisms involved in reagent decomposition and hydride formation [J].
D'Ulivo, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (06) :793-825
[8]   DETERMINATION OF CADMIUM IN AQUEOUS SAMPLES BY VAPOR GENERATION WITH SODIUM TETRAETHYLBORATE(III) REAGENT [J].
DULIVO, A ;
CHEN, YW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (04) :319-322
[9]   Atomic spectrometry update. Advances in atomic emission, absorption and fluorescence spectrometry, and related techniques [J].
Evans, E. Hywel ;
Day, Jason A. ;
Palmer, Christopher ;
Price, W. John ;
Smith, Clare M. M. ;
Tyson, Julian F. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (06) :592-625
[10]   Atomic spectrometry updates: Review of advances in atomic spectrometry and related techniques [J].
Evans, E. Hywel ;
Pisonero, Jorge ;
Smith, Clare M. M. ;
Taylor, Rex N. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (05) :773-794