Evaluation of Nonlinear Pre-sampled Modulation Transfer Function in Iterative Reconstruction CT

被引:1
作者
Jin, Hyeong Min [1 ]
Kim, Jong Hyo [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Interdisciplinary Program Radiat Appl Life Sci, Seoul, South Korea
来源
MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING | 2013年 / 8668卷
关键词
MTF; iterative reconstruction; CT; nonlinearity; spatial resolution; image quality assessment; IMAGE QUALITY; DOSE REDUCTION; PERFORMANCE; RADIOGRAPHY; SYSTEMS; MTF;
D O I
10.1117/12.2007823
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Iterative reconstruction (IR) technique is growingly used in clinical CT imaging with an expectation for improved image quality at lower patient doses. However, the nonlinear frequency response in different noise level and object contrast is less explored. In this study, we evaluate object contrast and dose level-dependent behavior of modulation transfer function in iterative reconstruction computed tomography imaging with a specially fabricated phantom. We created multi-contrast edge phantom, which consists of acrylic panel and diluted iodine contrast agent with different concentrations. Images were acquired with a multi-detector CT (Discovery CT750 HD: GE) at four dose levels (25, 50, 100 and 200mAs), and were reconstructed using FBP and two IR techniques (ASIR50 and VEO). Edge spread functions were extracted across angled edges on image, and were differentiated to yield line spread function. LSF were Fourier transformed to evaluate the presampled MTFs of IR and FBP reconstruction techniques. At same dose level (200mAs), the MTFs with higher contrast showed higher response than that of lower contrast in VEO. A MTF50 of 200mAs showed markedly higher responses up to 23% than that of 25mAs scan with VEO reconstruction for an edge phantom of 520HU contrast. Our study revealed that MTFs of IR technique degrades depending on noise level at low dose scan. Therefore, we recommend that its characteristic should be considered in quantitative analysis such as lesion size measurement.
引用
收藏
页数:7
相关论文
共 12 条
[1]   Determination of the presampled MTF in computed tomography [J].
Boone, JM .
MEDICAL PHYSICS, 2001, 28 (03) :356-360
[2]  
Fujita H., 1992, IEEE T MED IMAGING, V11, P4
[3]   Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771
[4]  
JUDY P F, 1976, Medical Physics (Woodbury), V3, P233, DOI 10.1118/1.594283
[5]   A comprehensive physical image quality evaluation of a selenium based digital x-ray imaging system for thorax radiography [J].
Launders, JH ;
Kengyelics, SM ;
Cowen, AR .
MEDICAL PHYSICS, 1998, 25 (06) :986-997
[6]   A Prospective Evaluation of Dose Reduction and Image Quality in Chest CT Using Adaptive Statistical Iterative Reconstruction [J].
Leipsic, Jonathon ;
Nguyen, Giang ;
Brown, Jaqueline ;
Sin, Don ;
Mayo, John R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) :1095-1099
[7]   TRANSFER-FUNCTION ANALYSIS OF RADIOGRAPHIC IMAGING-SYSTEMS [J].
METZ, CE ;
DOI, K .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (06) :1079-1106
[8]   Abdominal CT With Model-Based Iterative Reconstruction (MBIR): Initial Results of a Prospective Trial Comparing Ultralow-Dose With Standard-Dose Imaging [J].
Pickhardt, Perry J. ;
Lubner, Meghan G. ;
Kim, David H. ;
Tang, Jie ;
Ruma, Julie A. ;
del Rio, Alejandro Munoz ;
Chen, Guang-Hong .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) :1266-1274
[9]   Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms [J].
Richard, Samuel ;
Husarik, Daniela B. ;
Yadava, Girijesh ;
Murphy, Simon N. ;
Samei, Ehsan .
MEDICAL PHYSICS, 2012, 39 (07) :4115-4122
[10]   An experimental comparison of detector performance for direct and indirect digital radiography systems [J].
Samei, E ;
Flynn, MJ .
MEDICAL PHYSICS, 2003, 30 (04) :608-622