Biomechanical efficacy of AP, PA lag screws and posterior plating for fixation of posterior malleolar fractures: a three dimensional finite element study

被引:28
|
作者
Anwar, Adeel [1 ]
Zhang, Zhen [1 ]
Lv, Decheng [1 ]
Lv, Gang [2 ]
Zhao, Zhi [3 ]
Wang, Yanfeng [2 ]
Cai, Yue [4 ]
Qasim, Wasim [5 ]
Nazir, Muhammad Umar [6 ]
Lu, Ming [1 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Dept Orthoped Surg, 222 Zhongshan Rd, Dalian 116011, Liaoning, Peoples R China
[2] China Med Univ, Affiliated Hosp 1, Dept Orthopaed Surg, 155 Nanjing North St, Shenyang 110001, Liaoning, Peoples R China
[3] Dalian Med Univ, Affiliated Hosp 2, Dept Orthopaed Surg, 456 Zhongshan Rd, Dalian 116027, Liaoning, Peoples R China
[4] Dalian Jiaotong Univ, Sch Elect Engn, Dept Automat, 794 Huanghe Rd, Dalian 116028, Liaoning, Peoples R China
[5] Dalian Med Univ, Affiliated Hosp 2, Dept Gen Surg, 456 Zhongshan Rd, Dalian 116027, Liaoning, Peoples R China
[6] Dalian Med Univ, Affiliated Hosp 2, Dept Resp Med, 456 Zhongshan Rd, Dalian 116027, Liaoning, Peoples R China
来源
BMC MUSCULOSKELETAL DISORDERS | 2018年 / 19卷
关键词
Posterior malleolar fracture; Fixation; Biomechanical; Three dimensional; Finite element analysis; ANKLE FRACTURES; OPERATIVE TREATMENT; DELTOID LIGAMENT; TIBIAL MARGIN; CONTACT AREA;
D O I
10.1186/s12891-018-1989-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Clinically there are different fixation methods used for fixation of the posterior malleolar fractures (PMF), but the best treatment modality is still not clear. Few studies have concentrated on this issue, least of all using a biomechanical comparison. The purpose of this study was to carry out a computational comparative biomechanics of three different commonly used fixation constructs for the fixation of PMF by finite element analysis (FEA). Methods: Computed tomography (CT) images were used to reconstruct three dimensional (3D) model of the tibia. Computer aided design (CAD) software was used to design 3D models of PMF. Finally, 3D models of PMF fixed with two antero-posterior (AP) lag screws, two postero-anterior (PA) lag screws and posterior plate were simulated through computational processing. Simulated loads of 500 N, 1000 N and 1500 N were applied to the PMF and proximal ends of the models were fixed in all degrees of freedom. Output results representing the model von Mises stress, relative fracture micro-motion and vertical displacement of the fracture fragment were analyzed. Results: The mean vertical displacement value in the posterior plate group (0.52 mm) was lower than AP (0.68 mm) and PA (0.69 mm) lag groups. Statistically significant low amount of the relative micro-motion (P < 0.05) was observed in the posterior plate group. Conclusions: It was concluded that the posterior plate is biomechanically the most stable fixation method for fixation of PMF.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A novel external fixation for treating tibial fractures: a finite element and biomechanical study
    Liu, Shen
    Liang, Xiangdang
    Liu, Songyang
    Guo, Zhanshe
    Wei, Xing
    Liang, Yonghui
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [32] Biomechanical study of proximal adjacent segment degeneration after posterior lumbar interbody fusion and fixation: a finite element analysis
    Jiang, Shuai
    Li, Weishi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [33] Three-Dimensional Finite Element Analysis of Different Plating Techniques for Unfavorable Mandibular Angle Fractures
    Ayali, Aysa
    Erkmen, Erkan
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (03) : 603 - 607
  • [34] Talon cannulated compression device as an alternative in the fixation of acetabulum posterior column fractures: A biomechanical study
    Sibar, Kemal
    Alemdaroglu, Kadir Bahadir
    Elibol, Fatma Kubra Erbay
    Caliskan, Ozde Irem
    Demir, Teyfik
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (10):
  • [35] Biomechanical Evaluation of Bioabsorbable Versus Metallic Screws for Posterior Cruciate Ligament Inlay Graft Fixation A Comparative Study
    Gupta, Aman
    Lattermann, Christian
    Busam, Matthew
    Riff, Andrew
    Bach, Bernard R., Jr.
    Wang, Vincent M.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (04): : 748 - 753
  • [36] Biomechanical Role of the Thoracolumbar Ligaments of the Posterior Ligamentous Complex. A Finite Element Study
    Wu, Cong-Cong
    Jin, Hai-Ming
    Yan, Ying-Zhao
    Chen, Jian
    Wang, Ke
    Wang, Jian-Le
    Zhang, Zeng-Jie
    Wu, Ai-Min
    Wang, Xiang-Yang
    WORLD NEUROSURGERY, 2018, 112 : E125 - E133
  • [37] Biomechanical study of medial meniscus after posterior horn injury: a finite element analysis
    Jiang, Peishi
    Cui, Juncheng
    Chen, Zhiwei
    Dai, Zhu
    Zhang, Yangchun
    Yi, Guoliang
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (04) : 127 - 137
  • [38] Biomechanical efficacy of four different dual screws fixations in treatment of talus neck fracture: a three-dimensional finite element analysis
    Zhengrui Fan
    Jianxiong Ma
    Jian Chen
    Baocheng Yang
    Ying Wang
    Haohao Bai
    Lei Sun
    Yan Wang
    Bin Lu
    Ben-chao Dong
    Aixian Tian
    Xinlong Ma
    Journal of Orthopaedic Surgery and Research, 15
  • [39] Biomechanical efficacy of four different dual screws fixations in treatment of talus neck fracture: a three-dimensional finite element analysis
    Fan, Zhengrui
    Ma, Jianxiong
    Chen, Jian
    Yang, Baocheng
    Wang, Ying
    Bai, Haohao
    Sun, Lei
    Wang, Yan
    Lu, Bin
    Dong, Ben-chao
    Tian, Aixian
    Ma, Xinlong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [40] A Biomechanical Study of Various Fixation Strategies for the Treatment of Clavicle Fractures Using Three-Dimensional Upper-Body Musculoskeletal Finite Element Models
    Shih, Kao-Shang
    Hsu, Ching-Chi
    Shih, Bo-Yu
    APPLIED SCIENCES-BASEL, 2020, 10 (16):