Evaluation of a HbA1c point-of-care analyzer

被引:7
|
作者
Menendez-Valladares, Paloma [1 ]
Fernandez-Riejos, Patricia [1 ]
Sanchez-Mora, Catalina [1 ]
Perez-Perez, Antonio [1 ]
Sanchez-Margalet, Victor [1 ]
Gonzalez-Rodriguez, Concepcion [1 ]
机构
[1] Virgen Macarena Univ Hosp, Dept Clin Biochem, Seville 41009, Spain
关键词
POCT; HbA1c; Diabetes; Evaluation; GLYCATED HEMOGLOBIN; INSTRUMENTS; CAPILLARY; HBA(1C);
D O I
10.1016/j.clinbiochem.2015.03.016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: A better glycemic monitoring of diabetic patients and avoiding complications of poorly controlled diabetes could be possible with point-of-care testing technology (POCT) for HbA1c determination. B-Analyst (R) was studied to check whether it complied with the quality requirements for this purpose. Design and methods: We evaluated the B-Analyst (R) (Menarini Diagnostics), which is based in the principle of latex agglutination immunoturbidimetry, to assess the validity of the technique of HbA1c. We carried out the method comparison with the HA-8180 (R) (Menarini Diagnostics) as a reference method [High Performance Liquid Chromatography (HPLC)]. We assessed the analytical quality of the B-Analyst (R) studying the accuracy: inter-assay variability and intra-assay study. Furthermore, possible interferences by hemoglobinopathies were studied. Results: Regression analysis of the data for the method comparison between HA-8180 (R) and B-Analyst (R) showed a slope of 1.0085 and an intercept of 0.1208. The Pearson's correlation coefficient was 0.9958 (p < 0.0001). Bias study showed a mean difference from B-Analyst (R) with respect to HA-8180 (R) of 0.1872 with a 95% confidence interval. The standard error of the estimate (S-yx) was 0.2091. The concordance correlation coefficient to assess accuracy was 0.9922 (0.9891-0.9945). The CV for the inter-assay study was 1.4%. For the intra-assay study we analyzed 3 samples with different HbA1c % whose CV were 1.03% [4.7% HbA1c (28 mmol/mol)], 0.46% [6.4% HbA1c (46 mmol/mol)] and 0.78% [8.1% HbA1c (65 mmol/mol)]. Conclusion: The B-Analyst (R) evaluated not only showed good correlation with HA-8180 (R), but also it presented a great accuracy both in the inter-assay and in the intra-assay studies. The 8-Analyst (R) complies with quality specifications required for monitoring of diabetic patients. (C) 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:686 / 689
页数:4
相关论文
共 50 条
  • [31] Experience of point-of-care HbA1c testing in the English National Health Service Diabetes Prevention Programme: an observational study
    Barron, Emma
    Misra, Shivani
    English, Emma
    John, W. Garry
    Sampson, Michael
    Bachmann, Max O.
    Barth, Julian
    Oliver, Nick
    Alberti, K. G. M. M.
    Bakhai, Chirag
    O'Neill, Simon
    Young, Bob
    Wareham, Nicholas J.
    Khunti, Kamlesh
    Jebb, Susan
    Smith, Jenifer
    Valabhji, Jonathan
    BMJ OPEN DIABETES RESEARCH & CARE, 2020, 8 (02)
  • [32] Level of agreement of point-of-care and laboratory HbA1c measurements in the preoperative outpatient clinic in non-diabetic patients who are overweight or obese
    van Raalten, Floris
    Hiemstra, Yasmine L.
    Keulen, Noor
    van Duivenvoorde, Yoni
    Stoecklein, Katrin
    Verhagen, Evert A.
    Boer, Christa
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2019, 33 (06) : 1139 - 1144
  • [33] Diagnostic Accuracy of Point-of-Care Tests Measuring Glycosylated Haemoglobin (HbA1c) for Glycemic Control: A Field Study in India
    Khadanga, Sagar
    Singh, Gyanendra
    Pakhare, Abhijit P.
    Joshi, Rajnish
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [34] Analytical evaluation of the ADAMS A1c HA8180T analyzer for the measurement of HbA1c
    Urrechaga, Eloisa
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (01)
  • [35] Comparison of longitudinal point-of-care and high-performance liquid chromatography HbA1c measurements in a multi-centre trial
    Alleyn, C. R.
    Laffel, L. M. B.
    Volkening, L. K.
    Anderson, B. J.
    Nansel, T. R.
    Wysocki, T.
    Weissberg-Benchell, J.
    DIABETIC MEDICINE, 2011, 28 (12) : 1525 - 1529
  • [36] Real-world smartphone-based point-of-care diagnostics in primary health care to monitor HbA1c levels in people with diabetes
    Rhode, Sabrina
    Rogge, Lisa
    Marthoenis, Marthoenis
    Seuring, Till
    Zufry, Hendra
    Baernighausen, Till
    Sofyan, Hizir
    Manne-Goehler, Jennifer
    Vollmer, Sebastian
    COMMUNICATIONS MEDICINE, 2025, 5 (01):
  • [37] Evaluation of the performance of an immunoturbidimetric HbA1c reagent applied to the Siemens ADVIA 2400 automatic analyzer
    Barbaro, Mose
    Ku-Chulim, Carlos
    Johnston, Fran
    Cochrane, Rebecca
    Rota, Fabio
    Passerini, Gabriella
    Guerra, Elena
    Ceriotti, Ferruccio
    Carobene, Anna
    CLINICAL BIOCHEMISTRY, 2015, 48 (03) : 177 - 180
  • [38] Evaluation of 3 Hemoglobin A1c Point of Care Instruments. Point of Care Testing for HbA1c: Evaluation of Cobas b101, B-Analyst and Afinion™
    de Toro-Crespo, Maria
    Sanchez-Mora, Catalina
    Fernandez-Riejos, Patricia
    Maesa-Marquez, Jose M.
    Gonzalez-Rodriguez, Concepcion
    CLINICAL LABORATORY, 2017, 63 (7-8) : 1107 - 1112
  • [39] HbA1c method evaluation for postmortem samples
    Keltanen, Terhi
    Sajantila, Antti
    Valonen, Tiina
    Partanen, Teija
    Lindroos, Katarina
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2015, 11 (01) : 35 - 39
  • [40] HbA1c method evaluation for postmortem samples
    Terhi Keltanen
    Antti Sajantila
    Tiina Valonen
    Teija Partanen
    Katarina Lindroos
    Forensic Science, Medicine, and Pathology, 2015, 11 : 35 - 39