Evaluation of a HbA1c point-of-care analyzer

被引:7
|
作者
Menendez-Valladares, Paloma [1 ]
Fernandez-Riejos, Patricia [1 ]
Sanchez-Mora, Catalina [1 ]
Perez-Perez, Antonio [1 ]
Sanchez-Margalet, Victor [1 ]
Gonzalez-Rodriguez, Concepcion [1 ]
机构
[1] Virgen Macarena Univ Hosp, Dept Clin Biochem, Seville 41009, Spain
关键词
POCT; HbA1c; Diabetes; Evaluation; GLYCATED HEMOGLOBIN; INSTRUMENTS; CAPILLARY; HBA(1C);
D O I
10.1016/j.clinbiochem.2015.03.016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: A better glycemic monitoring of diabetic patients and avoiding complications of poorly controlled diabetes could be possible with point-of-care testing technology (POCT) for HbA1c determination. B-Analyst (R) was studied to check whether it complied with the quality requirements for this purpose. Design and methods: We evaluated the B-Analyst (R) (Menarini Diagnostics), which is based in the principle of latex agglutination immunoturbidimetry, to assess the validity of the technique of HbA1c. We carried out the method comparison with the HA-8180 (R) (Menarini Diagnostics) as a reference method [High Performance Liquid Chromatography (HPLC)]. We assessed the analytical quality of the B-Analyst (R) studying the accuracy: inter-assay variability and intra-assay study. Furthermore, possible interferences by hemoglobinopathies were studied. Results: Regression analysis of the data for the method comparison between HA-8180 (R) and B-Analyst (R) showed a slope of 1.0085 and an intercept of 0.1208. The Pearson's correlation coefficient was 0.9958 (p < 0.0001). Bias study showed a mean difference from B-Analyst (R) with respect to HA-8180 (R) of 0.1872 with a 95% confidence interval. The standard error of the estimate (S-yx) was 0.2091. The concordance correlation coefficient to assess accuracy was 0.9922 (0.9891-0.9945). The CV for the inter-assay study was 1.4%. For the intra-assay study we analyzed 3 samples with different HbA1c % whose CV were 1.03% [4.7% HbA1c (28 mmol/mol)], 0.46% [6.4% HbA1c (46 mmol/mol)] and 0.78% [8.1% HbA1c (65 mmol/mol)]. Conclusion: The B-Analyst (R) evaluated not only showed good correlation with HA-8180 (R), but also it presented a great accuracy both in the inter-assay and in the intra-assay studies. The 8-Analyst (R) complies with quality specifications required for monitoring of diabetic patients. (C) 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:686 / 689
页数:4
相关论文
共 50 条
  • [21] Systematic Diabetes Screening Using Point-of-Care HbA1c Testing Facilitates Identification of Prediabetes
    Whitley, Heather P.
    Hanson, Courtney
    Parton, Jason M.
    ANNALS OF FAMILY MEDICINE, 2017, 15 (02) : 162 - 164
  • [22] Measurement of HbA 1c at the Point-of-Care - clinical and practical aspects
    Schubert-Olesen, Oliver
    Niederau, Christoph
    Danschel, Ingrid
    Mueller-Wieland, Dirk
    Wiesner, Tobias
    DIABETOLOGIE UND STOFFWECHSEL, 2025,
  • [23] Evaluation of the Afinion AS100 Point-of-Care Analyzer for Hemoglobin A(1c)
    Arabadjief, Melissa
    Nichols, James H.
    POINT OF CARE, 2009, 8 (01): : 11 - 15
  • [24] How point-of-care HbA1c testing changes the behaviour of people with diabetes and clinicians - a qualitative study
    Hirst, J. A.
    Farmer, A. J.
    Williams, V.
    DIABETIC MEDICINE, 2020, 37 (06) : 1008 - 1015
  • [25] Point of Care Testing for HbA1c in Primary Care-cobas b 101 Instrument Evaluation
    Tirimacco, Rosy
    Cowley, Penelope J.
    Simpson, Paul A.
    Siew, Limei
    St John, Andrew
    Tideman, Philip A.
    POINT OF CARE, 2016, 15 (04): : 129 - 131
  • [26] Performance of Point-of-Care Testing Compared with the Standard Laboratory Diagnostic Test in the Measurement of HbA1c in Indonesian Diabetic and Nondiabetic Subjects
    Berbudi, Afiat
    Rahmadika, Nofri
    Tjahjadi, Adi Imam
    Ruslami, Rovina
    JOURNAL OF DIABETES RESEARCH, 2020, 2020
  • [27] Implementation of point-of-care HbA1C instruments into community pharmacies: Initial development of a pathway for robust community testing
    Radley, Andrew
    Beer, Lewis
    Rushdi, Danya
    Close, Hazel
    Mcburney, Stephen
    Mackenzie, Adrian
    Gourlay, Anna
    Barnett, Anna
    Grant, Alison
    Greig, Neil
    Dow, Ellie
    Sutherland, Calum
    ANNALS OF CLINICAL BIOCHEMISTRY, 2024, 61 (04) : 273 - 283
  • [28] Point-of-care capillary HbA1c measurement in the emergency department: a useful tool to detect unrecognized and uncontrolled diabetes
    Gomez-Peralta F.
    Abreu C.
    Andreu-Urioste L.
    Antolí A.C.
    Rico-Fontsaré C.
    Martín-Fernández D.
    Resina-Rufes R.
    Pérez-García J.J.
    Negrete-Muñoz Á.
    Muñoz-Álvarez D.
    Umpierrez G.E.
    International Journal of Emergency Medicine, 2016, 9 (1) : 1 - 6
  • [29] Using point-of-care HbA1c to facilitate the identification of diabetes and abnormal glucose regulation in primary healthcare settings
    Pi, Linhua
    Zheng, Ying
    Shi, Xiajie
    Wang, Zhen
    Zhou, Zhiguang
    FRONTIERS IN PUBLIC HEALTH, 2023, 11
  • [30] HbA1c screening in the community: Lessons for safety and quality management of a point of care programme
    Kenealy, Timothy
    Herd, Geoffrey
    Musaad, Samarina
    Wells, Susan
    PRIMARY CARE DIABETES, 2019, 13 (02) : 170 - 175