Evaluation of a HbA1c point-of-care analyzer

被引:7
|
作者
Menendez-Valladares, Paloma [1 ]
Fernandez-Riejos, Patricia [1 ]
Sanchez-Mora, Catalina [1 ]
Perez-Perez, Antonio [1 ]
Sanchez-Margalet, Victor [1 ]
Gonzalez-Rodriguez, Concepcion [1 ]
机构
[1] Virgen Macarena Univ Hosp, Dept Clin Biochem, Seville 41009, Spain
关键词
POCT; HbA1c; Diabetes; Evaluation; GLYCATED HEMOGLOBIN; INSTRUMENTS; CAPILLARY; HBA(1C);
D O I
10.1016/j.clinbiochem.2015.03.016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: A better glycemic monitoring of diabetic patients and avoiding complications of poorly controlled diabetes could be possible with point-of-care testing technology (POCT) for HbA1c determination. B-Analyst (R) was studied to check whether it complied with the quality requirements for this purpose. Design and methods: We evaluated the B-Analyst (R) (Menarini Diagnostics), which is based in the principle of latex agglutination immunoturbidimetry, to assess the validity of the technique of HbA1c. We carried out the method comparison with the HA-8180 (R) (Menarini Diagnostics) as a reference method [High Performance Liquid Chromatography (HPLC)]. We assessed the analytical quality of the B-Analyst (R) studying the accuracy: inter-assay variability and intra-assay study. Furthermore, possible interferences by hemoglobinopathies were studied. Results: Regression analysis of the data for the method comparison between HA-8180 (R) and B-Analyst (R) showed a slope of 1.0085 and an intercept of 0.1208. The Pearson's correlation coefficient was 0.9958 (p < 0.0001). Bias study showed a mean difference from B-Analyst (R) with respect to HA-8180 (R) of 0.1872 with a 95% confidence interval. The standard error of the estimate (S-yx) was 0.2091. The concordance correlation coefficient to assess accuracy was 0.9922 (0.9891-0.9945). The CV for the inter-assay study was 1.4%. For the intra-assay study we analyzed 3 samples with different HbA1c % whose CV were 1.03% [4.7% HbA1c (28 mmol/mol)], 0.46% [6.4% HbA1c (46 mmol/mol)] and 0.78% [8.1% HbA1c (65 mmol/mol)]. Conclusion: The B-Analyst (R) evaluated not only showed good correlation with HA-8180 (R), but also it presented a great accuracy both in the inter-assay and in the intra-assay studies. The 8-Analyst (R) complies with quality specifications required for monitoring of diabetic patients. (C) 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:686 / 689
页数:4
相关论文
共 50 条
  • [1] Performance evaluation of SD A1cCare as a HbA1c analyzer for point-of-care testing
    Lee, Kyunghoon
    Jun, Sun-Hee
    Han, Minje
    Song, Sang Hoon
    Park, Kyoung Un
    Song, Woon Heung
    Song, Junghan
    CLINICAL BIOCHEMISTRY, 2015, 48 (09) : 625 - 627
  • [2] Evaluation of two HbA1c point-of-care analyzers
    Sanchez-Mora, Catalina
    Rodriguez-Oliva, Manuel S.
    Fernandez-Riejos, Patricia
    Mateo, Joaquin
    Polo-Padillo, Juan
    Goberna, Raimundo
    Sanchez-Margalet, Victor
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (04) : 653 - 657
  • [3] Evaluation of a new hemoglobin A1c analyzer for point-of-care testing
    Zhou, Rui
    Wang, Wei
    Song, Zhi-Xin
    Tong, Qing
    Wang, Qing-Tao
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (01)
  • [4] Accuracy of point-of-care HbA1c testing in pregnant women
    Culliney, Katherine
    McCowan, Lesley M. E.
    Okesene-Gafa, Karaponi
    Murphy, Rinki
    Rowan, Janet
    Taylor, Rennae S.
    Mckinlay, Christopher J. D.
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2018, 58 (06) : 643 - 647
  • [5] Point-of-Care HbA1c in Clinical Practice: Caveats and Considerations for Optimal Use
    Sacks, David B.
    Kirkman, M. Sue
    Little, Randie R.
    DIABETES CARE, 2024, 47 (07) : 1104 - 1110
  • [6] An Evaluation of Point-of-Care HbA1c, HbA1c Home Kits, and Glucose Management Indicator: Potential Solutions for Telehealth Glycemic Assessments
    Zaharieva, Dessi P.
    Addala, Ananta
    Prahalad, Priya
    Leverenz, Brianna
    Arrizon-Ruiz, Nora
    Ding, Victoria Y.
    Desai, Manisha
    Karger, Amy B.
    Maahs, David M.
    DIABETOLOGY, 2022, 3 (03): : 494 - 501
  • [7] Evaluation of the In2it® analyzer for HbA1c determination
    Martin, M.
    Leroy, N.
    Sulmont, V.
    Gillery, P.
    DIABETES & METABOLISM, 2010, 36 (02) : 158 - 164
  • [8] Variation in Point-of-Care Testing of HbA1c in Diabetes Care in General Practice
    Kristensen, Troels
    Waldorff, Frans Boch
    Nexoe, Jorgen
    Skovsgaard, Christian Volmar
    Olsen, Kim Rose
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2017, 14 (11):
  • [9] Trends in Quantification of HbA1c Using Electrochemical and Point-of-Care Analyzers
    Mandali, Pavan Kumar
    Prabakaran, Amrish
    Annadurai, Kasthuri
    Krishnan, Uma Maheswari
    SENSORS, 2023, 23 (04)
  • [10] Accuracy and Clinical Utility of a Point-of-Care HbA1c Testing Device
    Knaebel, Jennifer
    Irvin, Benjamin R.
    Xie, Charles Z.
    POSTGRADUATE MEDICINE, 2013, 125 (03) : 91 - 98