An Approach to Determine Pressure Profile Generated by Compression Bandage Using Quasi-Linear Viscoelastic Model

被引:13
作者
Kumar, Bipin [1 ]
Das, Apurba [1 ]
Alagirusamy, R. [1 ]
机构
[1] Indian Inst Technol Delhi, Dept Text Technol, New Delhi 110016, India
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2012年 / 134卷 / 09期
关键词
viscoelasticity; bandaging system; wound care; compression therapy; STRESS-RELAXATION; LIGAMENTS; BEHAVIOR; FABRICS; LAW;
D O I
10.1115/1.4007176
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Understanding the stress relaxation behavior of the compression bandage could be very useful in determining the behavior of the interface pressure exerted by the bandage on a limb during the course of the compression treatment. There has been no comprehensive study in the literature to investigate the pressure profile (interface pressure with time) generated by a compression bandage when applied at different levels of strain. The present study attempts to describe the pressure profile, with the use of a quasi-linear viscoelastic model, generated by a compression bandage during compression therapy. The quasi-linear viscoelastic (QLV) theory proposed by Fung (Fung, 1972, "Stress Strain History Relations of Soft Tissues in Simple Elongation," Biomechanics: Its Foundations and Objectives, Y. C. Fung, N. Perrone, and M. Anliker, eds., Prentice-Hall, Englewood Cliffs, NJ, pp. 181-207). was used to model the nonlinear time- and history-dependent relaxation behavior of the bandage using the ramp strain approach. The regression analysis was done to find the correlation between the pressure profile and the relaxation behavior of the bandage. The parameters of the QLV model, describing the relaxation behavior of the bandage, were used to determine the pressure profile generated by the bandage at different levels of strain. The relaxation behaviors of the bandage at different levels of strain were well described by the QLV model parameters. A high correlation coefficient (nearly 0.98) shows a good correlation of the pressure profile with the stress relaxation behavior of the bandage. The prediction of the pressure profile using the QLV model parameters were in agreement with the experimental data. The pressure profile generated by a compression bandage could be predicted using the QLV model describing the nonlinear relaxation behavior of the bandage. This new application of the QLV theory helps in evaluating the bandage performance during compression therapy as scientific wound care management. [DOI: 10.1115/1.4007176]
引用
收藏
页数:5
相关论文
共 26 条
[1]   An improved method to analyze the stress relaxation of ligaments following a finite ramp time based on the quasi-linear viscoelastic theory [J].
Abramowitch, SD ;
Woo, SLY .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (01) :92-97
[2]  
[Anonymous], 2010, ANN BOOK ASTM STAND, V9, P6
[3]  
[Anonymous], 2007, ASTM INT, V07, P1
[4]   The Law of Laplace and its relevance to contemporary medicine and rehabilitation [J].
Basford, JR .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (08) :1165-1170
[5]   SUSTAINED COMPRESSION AND HEALING OF CHRONIC VENOUS ULCERS [J].
BLAIR, SD ;
WRIGHT, DDI ;
BACKHOUSE, CM ;
RIDDLE, E ;
MCCOLLUM, CN .
BRITISH MEDICAL JOURNAL, 1988, 297 (6657) :1159-1161
[6]  
Callam MJ., 1991, PHLEBOLOGY, V6, P79
[7]   Internal pressure profiling of medical bandages [J].
Das, A. ;
Alagirusamy, R. ;
Goel, D. ;
Garg, P. .
JOURNAL OF THE TEXTILE INSTITUTE, 2010, 101 (06) :481-487
[8]  
Das A., 2011, IND J FIBRE IN PRESS
[9]   PARAMETER-ESTIMATION USING THE QUASI-LINEAR VISCOELASTIC MODEL PROPOSED BY FUNG [J].
DORTMANS, LJMG ;
SAUREN, AAHJ ;
ROUSSEAU, EPM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (03) :198-203
[10]  
Fung YC., 1972, BIOMECHANICS ITS FDN, P181