Monte Carlo simulations to support start-up and treatment planning of scanned proton and carbon ion therapy at a synchrotron-based facility

被引:179
作者
Parodi, K. [1 ,2 ]
Mairani, A. [1 ,2 ,3 ]
Brons, S. [1 ,2 ]
Hasch, B. G. [1 ,2 ]
Sommerer, F. [1 ,2 ,4 ]
Naumann, J. [1 ,2 ]
Jaekel, O. [1 ,2 ]
Haberer, T. [1 ,2 ]
Debus, J. [1 ,2 ]
机构
[1] Heidelberg Univ Clin, Heidelberg Ion Beam Therapy Ctr, Heidelberg, Germany
[2] Heidelberg Univ Clin, Dept Radiat Oncol, Heidelberg, Germany
[3] German Canc Res Ctr, D-6900 Heidelberg, Germany
[4] European Org Nucl Res CERN, Geneva, Switzerland
关键词
DOSE DISTRIBUTION; FLUKA CODE; SKULL-BASE; RADIOTHERAPY; SYSTEM; MODEL; BEAMS; VERIFICATION; DESIGN;
D O I
10.1088/0031-9155/57/12/3759
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Reliable treatment planning of highly conformal scanned ion beam therapy demands accurate tools for the determination and characterization of the individual pencil-like beams building up the integral dose delivery and related mixed radiation field. At present, clinically practicable inverse treatment planning systems (TPSs) can only rely on fast-performing analytical algorithms. However, the rapidly emerging though more computationally intensive Monte Carlo (MC) methods can be employed to complement analytical TPS, e.g., via accurate calculations of the input beam-model data, together with a considerable reduction of the measuring time. Here we present the work done for the application of the FLUKA MC code to support several aspects of scanned ion beam delivery and treatment planning at the Heidelberg Ion Beam Therapy Center (HIT). Emphasis is given to the generation of the accelerator library and of experimentally validated TPS input basic data which are now in clinical use for proton and carbon ion therapy. Additionally, MC dose calculations of planned treatments in water are shown to represent a valuable tool for supporting treatment plan verification in comparison to dosimetric measurements. This paper can thus provide useful information and guidelines for the start-up and clinical operation of forthcoming ion beam therapy facilities similar to HIT.
引用
收藏
页码:3759 / 3784
页数:26
相关论文
共 44 条
[1]  
Ackermann B, 2009, PROGR ABSTR HEAV ION, P57
[2]  
[Anonymous], 1993, 49 ICRU
[3]  
Battistoni G, 2007, AIP CONF PROC, V896, P31, DOI 10.1063/1.2720455
[4]   Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy [J].
Bohlen, T. T. ;
Cerutti, F. ;
Dosanjh, M. ;
Ferrari, A. ;
Gudowska, I. ;
Mairani, A. ;
Quesada, J. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (19) :5833-5847
[5]   An analytical approximation of the Bragg curve for therapeutic proton beams [J].
Bortfeld, T .
MEDICAL PHYSICS, 1997, 24 (12) :2024-2033
[6]  
Brons S, 2005, 20051296 GSI HELMH S
[7]  
Cerutti F., 2006, P 11 INT C NUCL REAC, P507
[8]   QUANTIFICATION OF THE RELATIVE BIOLOGICAL EFFECTIVENESS FOR ION BEAM RADIOTHERAPY: DIRECT EXPERIMENTAL COMPARISON OF PROTON AND CARBON ION BEAMS AND A NOVEL APPROACH FOR TREATMENT PLANNING [J].
Elsaesser, Thilo ;
Weyrather, Wilma K. ;
Friedrich, Thomas ;
Durante, Marco ;
Iancu, Gheorghe ;
Kraemer, Michael ;
Kragl, Gabriele ;
Brons, Stephan ;
Winter, Marcus ;
Weber, Klaus-Josef ;
Scholz, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (04) :1177-1183
[9]  
Ferrari A., 2005, CERN200510, DOI [DOI 10.2172/877507, 10.5170/CERN-2005-010, DOI 10.5170/CERN-2005-010]
[10]   Performance of the NIRS fast scanning system for heavy-ion radiotherapy [J].
Furukawa, Takuji ;
Inaniwa, Taku ;
Sato, Shinji ;
Shirai, Toshiyuki ;
Takei, Yuka ;
Takeshita, Eri ;
Mizushima, Kota ;
Iwata, Yoshiyuki ;
Himukai, Takeshi ;
Mori, Shinichiro ;
Fukuda, Shigekazu ;
Minohara, Shinichi ;
Takada, Eiichi ;
Murakami, Takeshi ;
Noda, Koji .
MEDICAL PHYSICS, 2010, 37 (11) :5672-5682