Quality indexes based on water measurements for low and medium energy x-ray beams: A theoretical study with PENELOPE

被引:4
作者
Chica, U. [1 ,2 ]
Anguiano, M. [1 ]
Vilches, M. [3 ]
Lallena, A. M. [1 ]
机构
[1] Univ Granada, Dept Fis Atom Mol & Nucl, E-18071 Granada, Spain
[2] FISRAD SAS, Bogota, Colombia
[3] Hosp Univ San Cecilio, Serv Radiofis, E-18012 Granada, Spain
关键词
quality indexes; x-ray beams; PENELOPE; IONIZATION CHAMBERS; 300; KV; DOSIMETRY; SPECTRA; RADIOTHERAPY; PROTOCOL; TARGETS; IPEMB; CODE; TUBE;
D O I
10.1118/1.4836556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To study the use of quality indexes based on ratios of absorbed doses in water at two different depths to characterize x-ray beams of low and medium energies. Methods: A total of 55 x-ray beam spectra were generated with the codes XCOMP5R and SPEKCALC and used as input of a series of Monte Carlo simulations performed with PENELOPE, in which the percentage depth doses in water and the k(Q), Q(0) factors, defined in the TRS-398 protocol, were determined for each beam. Some of these calculations were performed by simulating the ionization chamber PTW 30010. Results: The authors found that the relation between k(Q), Q(0) and the ratios of absorbed doses at two depths is almost linear. A set of ratios statistically compatible with that showing the best fit has been determined. Conclusions: The results of this study point out which of these ratios of absorbed doses in water could be used to better characterize x-ray beams of low and medium energies. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:8
相关论文
共 22 条
[1]   Benchmark of PENELOPE for low and medium energy X-rays [J].
Chica, U. ;
Anguiano, M. ;
Lallena, A. M. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (02) :51-57
[2]   Study of the formalism used to determine the absorbed dose for low-energy x-ray beams [J].
Chica, U. ;
Anguiano, M. ;
Lallena, A. M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (23) :6963-6977
[3]  
Deutsch Institut fur Normung (DIN), 1996, DIN68095
[4]  
Frodesen A.G., 1979, Probability and Statistics in Particle Physics
[5]   An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams [J].
Hill, Robin ;
Mo, Zhao ;
Haque, Mamoon ;
Baldock, Clive .
MEDICAL PHYSICS, 2009, 36 (09) :3971-3981
[6]  
IAEA, 1987, IAEA TECHN REP SER, V277
[7]  
International Atomic Energy Agency, 2000, IAEA TRS-398
[8]  
International Commission on Radiation Units and Measurements, 1964, 10B ICRU
[9]  
Klevenhagen SC, 1996, PHYS MED BIOL, V41, P2605, DOI 10.1088/0031-9155/41/12/002
[10]   AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology [J].
Ma, CM ;
Coffey, CW ;
DeWerd, LA ;
Liu, C ;
Nath, R ;
Seltzer, SM ;
Seuntjens, JP .
MEDICAL PHYSICS, 2001, 28 (06) :868-893