Rotating-wave-plate Stokes polarimeter for differential group delay measurements of polarization-mode dispersion

被引:57
作者
Williams, PA [1 ]
机构
[1] Natl Inst Stand & Technol, Div Optoelect, Boulder, CO 80303 USA
关键词
D O I
10.1364/AO.38.006508
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a description and detailed uncertainty analysis of a polarization-mode dispersion (PMD) measurement system that uses the Jones matrix eigenanalysis measurement technique based on a rotating-wave-plate Stokes polarimeter. The uncertainty of the system is 3.2 fs (similar to 95% confidence interval) and is due primarily to PMD in the fiber leads of the measurement system. OCIS codes: 060.2270, 060.2300.
引用
收藏
页码:6508 / 6515
页数:8
相关论文
共 15 条