Study on locating transformer internal faults using sweep frequency response analysis

被引:19
作者
Khanali, Mahdi [1 ]
Hayati-Soloot, Amir [2 ]
Hoidalen, Hans Kristian [2 ]
Jayaram, Shesha [1 ]
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, High Voltage Engn Lab HVEL, Waterloo, ON N2L 3G1, Canada
[2] Norwegian Univ Sci & Technol, Elect Power Engn Dept, N-7491 Trondheim, Norway
基金
加拿大自然科学与工程研究理事会;
关键词
Sweep frequency response analysis; Internal short circuit; Inter-turn fault location; Transfer function; Transformer fault diagnosis; DEFORMATION;
D O I
10.1016/j.epsr.2016.11.016
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As an extensive network of resistances, capacitances, and inductances, a transformer has inherent characteristic parameters that are functions of frequency. The form of these functions is predicated on the geometric design of the transformer and materials that comprise it. Any change in the structure of a transformer will be reflected in its frequency response characteristics, Of the possible changes that can take place in a transformer structure, an internal short circuit is one Of the far-reaching incidents that has been recently reported for many wind-farm transformers. Detecting the location of an internal short circuit that has occurred in a transformer winding is therefore beneficial in the repair process and also in improving future designs. In an effort to identify trends with inter-turn fault locations and frequency responses, this research investigates the effect of the location of deliberately initiated internal faults on parameters such as transfer voltages and input impedances by means of sweep frequency response analysis (SFRA). The analysis of three different model transformers with different core and winding designs shows several trends in frequency response patterns, depending on the location of the internal short circuits. The paper discusses such trends as a potential use of SFRA in locating inter-turn winding failures that may result in noticeable short circuits. (C) 2016 Published by Elsevier B.V.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 17 条
  • [11] Merrikhi J, 2006, 2006 2ND INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS, P78
  • [12] Investigation on the high frequency, high voltage insulation properties of mineral transformer-oil
    Nagel, M.
    Leibfried, T.
    [J]. 2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 226 - 228
  • [13] A New Method for Purposes of Failure Diagnostics and FRA Interpretation applicable to Power Transformers
    Pham, D. A. K.
    Pham, T. M. T.
    Borsi, H.
    Gockenbach, E.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2026 - 2034
  • [14] Modeling and Diagnostic Transformer Condition Using Sweep Frequency Response Analysis
    Purnomoadi, A. P.
    Fransisco, D.
    [J]. ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 1059 - +
  • [15] Sweep frequency response analysis (SFRA) for the assessment of winding displacements and deformation in power transformers
    Secue, J. R.
    Mombello, E.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (06) : 1119 - 1128
  • [16] Influence of the Winding Design of Wind Turbine Transformers for Resonant Overvoltage Vulnerability
    Soloot, Amir Hayati
    Hoidalen, Hans Kristian
    Gustavsen, Bjorn
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (02) : 1250 - 1257
  • [17] Wilk A., 2011, 2011 IEEE 20th International Symposium on Industrial Electronics (ISIE 2011), P631, DOI 10.1109/ISIE.2011.5984231