Experimental research on performances of the imaging plates applied in gamma-ray imaging

被引:2
作者
Qi Jian-Min [1 ]
Zhang Fa-Qiang [1 ]
Chen Jin-Chuan [1 ]
Xie Hong-Wei [1 ]
机构
[1] China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621900, Peoples R China
关键词
gamma-ray imaging; imaging plate; linear calibration; time attenuation; gamma-ray sensitivity; DETECTORS;
D O I
10.1088/1674-1137/38/1/016001
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Experimental studies on the basic characteristics of IPs applied in gamma-ray imaging are carried out by utilizing isotopic gamma-ray sources. The 1.25 MeV gamma-ray sensitivity of the BAS-MS and BAS-TR imaging plates and their enhanced sensitivity by covering appropriate Compton conversion foils are measured based on the studies of the image intensity linear calibration, time attenuation laws and the influence of scanning parameter settings. The energy-dependent gamma-ray sensitivity of the IPs is also obtained by the studies of the measured sensitivity and the Monte Carlo simulated energy deposition in the IPs' sensitive layer. Furthermore, a method of a sandwich detection structure as well as its primary experimental validations are presented in order to increase the gamma-to-neutron ratio in a gamma/n mixed radiation field.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] A monolithic array of silicon drift detectors for high-resolution gamma-ray imaging
    Fiorini, C.
    Longoni, A.
    Perotti, F.
    Labanti, C.
    Rossi, E.
    Lechner, P.
    Soltau, H.
    Strüder, Lothar
    IEEE Transactions on Nuclear Science, 2002, 49 II (03) : 995 - 1000
  • [32] Gamma-ray imaging of Np-237 metal using an organic glass imager
    Lopez, R.
    Pakari, O.
    Clarke, S. D.
    Pozzi, S. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1063
  • [33] Scene data fusion: Real-time standoff volumetric gamma-ray imaging
    Barnowski, Ross
    Haefner, Andrew
    Mihailescu, Lucian
    Vetter, Kai
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 800 : 65 - 69
  • [34] A Novel Gamma-Ray Imaging System Using a Coded-Aperture Compton Camera
    Farber, Aaron M.
    Williams, John G.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 450 - 454
  • [35] A double-tapered fibre array for pixel-dense gamma-ray imaging
    Yi, Luying
    Hou, Bo
    Zhao, He
    Tan, Hong Qi
    Liu, Xiaogang
    NATURE PHOTONICS, 2023, 17 (06) : 494 - +
  • [36] A monolithic array of silicon drift detectors for high-resolution gamma-ray imaging
    Fiorini, C
    Longoni, A
    Perotti, F
    Labanti, C
    Rossi, E
    Lechner, P
    Soltau, H
    Strüder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 995 - 1000
  • [37] Gamma ray detectors for breast imaging
    Williams, MB
    Goode, AR
    Majewski, S
    Steinbach, D
    Weisenberger, AG
    Wojcik, R
    Farzanpay, F
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 : 226 - 234
  • [38] A monolithic array of 77 Silicon Drift Detectors for X-ray spectroscopy and gamma-ray imaging applications
    Fiorini, C
    Bellini, M
    Gola, A
    Longoni, A
    Perotti, E
    Lechner, P
    Soltau, H
    Strüder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 1165 - 1170
  • [39] Hard X-ray and Gamma-ray Imaging and Spectroscopy using Scintillators coupled to Silicon Drift Detectors
    Lechner, P.
    Eckhard, R.
    Fiorini, C.
    Gola, A.
    Longoni, A.
    Niculae, A.
    Peloso, R.
    Soltau, H.
    Strueder, L.
    HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY III, 2008, 7021
  • [40] Fast neutron and γ-ray dosimetry with imaging plates
    Boukhair, A
    Heilmann, C
    Nourreddine, A
    Pape, A
    Portal, G
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 513 - 516