Experimental research on performances of the imaging plates applied in gamma-ray imaging

被引:2
|
作者
Qi Jian-Min [1 ]
Zhang Fa-Qiang [1 ]
Chen Jin-Chuan [1 ]
Xie Hong-Wei [1 ]
机构
[1] China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621900, Peoples R China
关键词
gamma-ray imaging; imaging plate; linear calibration; time attenuation; gamma-ray sensitivity; DETECTORS;
D O I
10.1088/1674-1137/38/1/016001
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Experimental studies on the basic characteristics of IPs applied in gamma-ray imaging are carried out by utilizing isotopic gamma-ray sources. The 1.25 MeV gamma-ray sensitivity of the BAS-MS and BAS-TR imaging plates and their enhanced sensitivity by covering appropriate Compton conversion foils are measured based on the studies of the image intensity linear calibration, time attenuation laws and the influence of scanning parameter settings. The energy-dependent gamma-ray sensitivity of the IPs is also obtained by the studies of the measured sensitivity and the Monte Carlo simulated energy deposition in the IPs' sensitive layer. Furthermore, a method of a sandwich detection structure as well as its primary experimental validations are presented in order to increase the gamma-to-neutron ratio in a gamma/n mixed radiation field.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Semiconductor drift detectors for X- and gamma-ray spectroscopy and imaging
    Fiorini, C.
    Longoni, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (10) : 2173 - 2181
  • [22] GAMMA-RAY OBSERVATIONS IN THE GALACTIC-CENTER REGION WITH AN IMAGING DETECTOR
    SAMIMI, J
    KINZER, RL
    ASTROPHYSICAL JOURNAL, 1994, 434 (01) : 136 - 144
  • [23] Applications and imaging techniques of a Si/CdTe Compton gamma-ray camera
    Takeda, Shin'ichiro
    Ichinohe, Yuto
    Hagino, Kouichi
    Odaka, Hirokazu
    Yuasa, Takayuki
    Ishikawa, Shin-nosuke
    Fukuyama, Taro
    Saito, Shinya
    Sato, Tamotsu
    Sato, Goro
    Watanabe, Shin
    Kokubun, Motohide
    Takahashi, Tadayuki
    Yamaguchi, Mitsutaka
    Tajima, Hiroyasu
    Tanaka, Takaaki
    Nakazawa, Kazuhiro
    Fukazawa, Yasushi
    Nakano, Takashi
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 859 - 866
  • [24] Position-sensitive germanium detectors for gamma-ray imaging and spectroscopy
    Amman, M
    Luke, PN
    HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II, 2000, 4141 : 144 - 156
  • [25] Imaging performances of the DRAGO gamma camera
    Fiorini, C.
    Gola, A.
    Peloso, R.
    Longoni, A.
    Lechner, P.
    Soltau, H.
    Strueder, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2) : 101 - 103
  • [26] CZT detectors with 3-D readout for gamma-ray spectroscopy and imaging
    Matteson, JL
    Pelling, MR
    Skelton, RT
    X-RAY AND GAMMA-RAY DETECTORS AND APPLICATIONS IV, 2002, 4784 : 1 - 13
  • [27] Apparent image formation by Compton-scattered photons in gamma-ray imaging
    Nguyen, MK
    Faye, C
    Eglin, L
    Truong, TT
    IEEE SIGNAL PROCESSING LETTERS, 2001, 8 (09) : 248 - 251
  • [28] Study on gamma-ray imaging with an image-intensifier and a cooled CCD camera
    Saitoh, N
    Kuroki, K
    Kurosawa, K
    Akiba, N
    ENABLING TECHNOLOGIES FOR LAW ENFORCEMENT AND SECURITY, 2000, 4232 : 497 - 504
  • [29] The Kaguya gamma-ray spectrometer: instrumentation and in-flight performances
    Kobayashi, M.
    Hasebe, N.
    Miyachi, T.
    Fujii, M.
    Shibamura, E.
    Okudaira, O.
    Karouji, Y.
    Hareyama, M.
    Takashima, T.
    Kobayashi, S.
    d'Uston, C.
    Maurice, S.
    Yamashita, N.
    Reedy, Robert C.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [30] Handheld real-time volumetric 3-D gamma-ray imaging
    Haefner, Andrew
    Barnowski, Ross
    Luke, Paul
    Amman, Mark
    Vetter, Kai
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 857 : 42 - 49