Accuracy of miniscrew surgical guides assessed from cone-beam computed tomography and digital models

被引:55
作者
Bae, Mi-Ju [1 ]
Kim, Ji-Young [2 ]
Park, Jong-Tae [3 ]
Cha, Jung-Yul [1 ]
Kim, Hee-Jin [4 ]
Yu, Hyung-Seog [1 ]
Hwang, Chung-Ju [1 ]
机构
[1] Yonsei Univ, Coll Dent, Dept Orthodont, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Dent, Dept Orthodont, Inst Craniofacial Deform, Seoul 120752, South Korea
[3] Yonsei Univ, Coll Dent, Div Anat & Dev Biol, Dept Oral Biol,Human Identificat Res Ctr, Seoul 120752, South Korea
[4] Yonsei Univ, Coll Dent, Div Anat & Dev Biol, Dept Oral Biol, Seoul 120752, South Korea
关键词
CORTICAL BONE THICKNESS; IMPLANT PLACEMENT; ORTHODONTIC MINISCREWS; ROOT PROXIMITY; MINI-IMPLANT; MAXILLARY; INSERTION; CONTACT; FAILURE;
D O I
10.1016/j.ajodo.2013.02.018
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Several methods are available to enhance the precision of miniscrew placement. The use of surgical guides based on cone-beam computed tomography is indicated especially in patients with risky or difficult anatomic situations. The purpose of this study was to evaluate the accuracy of miniscrew placement by using surgical guides developed with computer-aided design and manufacturing techniques. Methods: Miniscrews were placed in cadaver maxillae using stereolithographic computer-aided design and manufacturing techniques with assistance from surgical guides (surgical guide group, n = 25) or periapical x-rays (control group, n 5 20). Insertion sites were selected using a 3-dimensional surgical planning program by fusing maxillary digital model images and cone-beam computed tomography images. Deviations between actual and planned placements were measured as 3-dimensional angular deviations and distance (coronal and apical) deviations. Results: In the surgical guide group, the angular deviation was a median of 3.14 degrees (range, 1.02 degrees-10.9 degrees), and the mesiodistal deviations in the coronal and apical areas were medians of 0.29 mm (range, 0.03-0.73 mm) and 0.21 mm (range, 0.03-0.97 mm), respectively. The deviations differed significantly between operators in the control group, but not in the surgical guide group. In the surgical guide group, there was no root damage from miniscrew placement, and 84% of the miniscrews were placed without contacting adjacent anatomic structures. In the control group, 50% of the miniscrews were placed between the roots (P <0.05). Conclusions: Surgical guide accuracy was improved when digital model imaging was used. Miniscrews were placed more accurately when using surgical guides than when using a direct method. (Am J Orthod Dentofacial Orthop 2013;143:893-901)
引用
收藏
页码:893 / 901
页数:9
相关论文
共 29 条
[1]   Root contact during insertion of miniscrews for orthodontic anchorage increases the failure rate: an animal study [J].
Chen, Yuan-Hou ;
Chang, Hao-Hueng ;
Chen, Yi-Jane ;
Lee, David ;
Chiang, Hsien-Hsiung ;
Yao, Chung-Chen Jane .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (01) :99-106
[2]   Accuracy and Complications Using Computer-Designed Stereolithographic Surgical Guides for Oral Rehabilitation by Means of Dental Implants: A Review of the Literature [J].
D'haese, Jan ;
Van De Velde, Tommie ;
Komiyama, Ai ;
Hultin, Margaretha ;
De Bruyn, Hugo .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (03) :321-335
[3]   Accuracy of a computerized tomography-guided template-assisted implant placement system: an in vitro study [J].
Horwitz, Jacob ;
Zuabi, Otman ;
Machtei, Eli E. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (10) :1156-1162
[4]   Contact damage to root surfaces of premolars touching miniscrews during orthodontic treatment [J].
Kadioglu, Onur ;
Buyukyilmaz, Tamer ;
Zachrisson, Bjoern U. ;
Maino, B. Giuliano .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (03) :353-360
[5]   Evaluation of interdental space of the maxillary posterior area for orthodontic mini-implants with cone-beam computed tomography [J].
Kim, Seong-Hun ;
Yoon, Hyeong-Gun ;
Choi, Yong-Suk ;
Hwang, Eui-Hwan ;
Kook, Yoon-Ah ;
Nelson, Gerald .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (05) :635-641
[6]   Root proximity is a major factor for screw failure in orthodontic anchorage [J].
Kuroda, Shingo ;
Yamada, Kazuyo ;
Deguchi, Toru ;
Hashimoto, Takashi ;
Kyung, Hee-Moon ;
Takano-Yamamoto, Teruko .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (04) :S68-S73
[7]   Computed tomographic analysis of tooth-bearing alveolar bone for orthodontic miniscrew placement [J].
Lee, Kee-Joon ;
Joo, Euk ;
Kim, Kee-Deog ;
Lee, Jong-Suk ;
Park, Young-Chel ;
Yu, Hyung-Seog .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (04) :486-494
[8]   Root and Bone Response to the Proximity of a Mini-Implant under Orthodontic Loading [J].
Lee, Yang-Ku ;
Kim, Jong-Wan ;
Baek, Seung-Hak ;
Kim, Tae-Woo ;
Chang, Young-Il .
ANGLE ORTHODONTIST, 2010, 80 (03) :452-458
[9]   Use of miniscrews and miniplates in orthodontics [J].
Leung, Michael Tat-Chi ;
Lee, Tony Cheuk-Kit ;
Rabie, A. Bakr M. ;
Wong, Ricky Wing-Kit .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 66 (07) :1461-1466
[10]   Quantitative evaluation of cortical bone thickness and root proximity at maxillary interradicular sites for orthodontic mini-implant placement [J].
Lim, Ju-Eun ;
Lim, Won Hee ;
Chun, Yoon Sic .
CLINICAL ANATOMY, 2008, 21 (06) :486-491