Improving the performance of an integrated urban wastewater system under future climate change and urbanisation scenarios

被引:4
作者
Astaraie-Imani, Maryam [1 ]
Kapelan, Zoran [1 ]
Butler, David [1 ]
机构
[1] Univ Exeter, Ctr Water Syst, Coll Engn Math & Phys Sci, Exeter EX4 4QF, Devon, England
关键词
climate change; design; integrated modelling; operational control; optimisation; urbanisation; urban wastewater system; COMBINED-SEWER OVERFLOWS;
D O I
10.2166/wcc.2013.078
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
This paper presents the results of a study to investigate the performance of an integrated urban wastewater system (IUWS) consisting of a sewer system, biological wastewater treatment plant and receiving water under future climate change and urbanisation. In particular, the roles of both system operational control and (re) design were studied as means to ensure future compliance of the system with recipient water quality standards. This is carried out by applying a scenario-based approach to describe the possible features of future climate change and/or urbanisation. Dissolved oxygen and ammonium concentrations are considered as the objectives of the optimisation models. Critical flow rates in the IUWS are considered as decision variables of the operational control model and sewer storage tank volume is considered as the design model decision variable in this study. It is demonstrated that operational control optimisation alone, under all the scenarios developed, does not have enough potential to cope with these future conditions and only when combined with design optimisation can adequate performance be guaranteed.
引用
收藏
页码:232 / 243
页数:12
相关论文
共 25 条
[11]   Multiple objective optimal control of integrated urban wastewater systems [J].
Fu, Guangtao ;
Butler, David ;
Khu, Soon-Thiam .
ENVIRONMENTAL MODELLING & SOFTWARE, 2008, 23 (02) :225-234
[12]  
FWR, 1998, FRCL0009 FWR
[13]  
HENZE M, 1986, 1 LAWQ
[14]  
Hulme M., 2002, CLIMATE CHANGE SCENA, P120
[15]  
*IFAK, 2005, SIMBA 5 0 SIM WAST S
[16]  
*ITWH, 1995, MIKR STADT MISCHW
[17]  
Lau J., 2002, URBAN WAT, V4, P181, DOI [10.1016/S1462-0758(02)00013-4, DOI 10.1016/S1462-0758(02)00013-4, 10.1016/S1462-0758%4002%4100013-4]
[18]   DYNAMIC MODELING OF THE ACTIVATED-SLUDGE PROCESS - A CASE-STUDY [J].
LESSARD, P ;
BECK, MB .
WATER RESEARCH, 1993, 27 (06) :963-978
[19]  
LESSARD P, 1989, THESIS U LONDON LOND
[20]  
Lijklema L., 1996, Procesbeschrijvingen DUFLOW: Zuurstofhuishouding in stromende en stagnante watersystemen