Performance Study of E-Nose Measurement Chamber for Environmental Odour Monitoring

被引:26
作者
Viccione, Giacomo [1 ]
Zarra, Tiziano [2 ]
Giuliani, Stefano [2 ]
Naddeo, Vincenzo [2 ]
Belgiorno, Vincenzo [2 ]
机构
[1] Univ Salerno, LIDAM, Via Ponte Don Melillo 1, I-84084 Fisciano, SA, Italy
[2] Univ Salerno, SEED, I-84084 Fisciano, SA, Italy
来源
NOSE 2012: 3RD INTERNATIONAL CONFERENCE ON ENVIRONMENTAL ODOUR MONITORING AND CONTROL | 2012年 / 30卷
关键词
ELECTRONIC NOSES;
D O I
10.3303/CET1230019
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Offensive odours from industrial and sanitary environmental engineering plants can cause problems, such as sleep disorders, migraine and loss of appetite, also considering that they address the quality of life. Odour emission characterization is currently discussed in international literature as to determine its most feasible implementation. A method for continuous odour monitoring is based on the use of electronic noses. Electronic nose is an instrument which comprises an array of electronic chemical sensors with partial specificity and an appropriate pattern recognition system, capable of recognizing simple or complex odours. Aim of this work is to numerically analyze the performance of a sensor chamber in order to improve sensor response signals in terms of stability, reproducibility and response time. Comparative results are based on the location of four different diffusers. The numerical analysis was performed by a computational fluid dynamic (CFD) software in order to guarantee that all sensors are exposed to the same chemical sample under the same experimental conditions for the same time, reducing the presence of stagnant or recirculating regions.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 10 条
[1]   The use of sensor arrays for environmental monitoring: interests and limitations [J].
Bourgeois, W ;
Romain, AC ;
Nicolas, J ;
Stuetz, RM .
JOURNAL OF ENVIRONMENTAL MONITORING, 2003, 5 (06) :852-860
[2]  
Flow Sciences, 2009, FLOW 3D US MAN REL 9
[3]  
GARDNER JW, 1994, SENSOR ACTUAT B-CHEM, V18, P211
[4]   VOLUME OF FLUID (VOF) METHOD FOR THE DYNAMICS OF FREE BOUNDARIES [J].
HIRT, CW ;
NICHOLS, BD .
JOURNAL OF COMPUTATIONAL PHYSICS, 1981, 39 (01) :201-225
[5]   Influence of gaseous species transport on the response of solid state gas sensors within enclosures [J].
Lezzi, AM ;
Beretta, GP ;
Comini, E ;
Faglia, G ;
Galli, G ;
Sberveglieri, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 78 (1-3) :144-150
[6]   Electronic noses: specify or disappear [J].
Mielle, P ;
Marquis, F ;
Latrasse, C .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) :287-294
[7]   Optimising of the sensing chamber of an array of a volatile detection system - Fluid dynamic simulation [J].
Scott, SM ;
James, D ;
Ali, Z ;
O'Hare, WT .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2004, 76 (02) :693-708
[8]   Odour monitoring of small wastewater treatment plant located in sensitive environment [J].
Zarra, T. ;
Naddeo, V. ;
Belgiorno, V. ;
Reiser, M. ;
Kranert, M. .
WATER SCIENCE AND TECHNOLOGY, 2008, 58 (01) :89-94
[9]   Optimization of field inspection method for odour impact assessment [J].
Zarra, T. ;
Naddeo, V ;
Giuliani, S. ;
Belgiorno, V .
NOSE 2010: INTERNATIONAL CONFERENCE ON ENVIRONMENTAL ODOUR MONITORING AND CONTROL, 2010, 23 :93-98
[10]   Instrumental characterization of odour: a combination of olfactory and analytical methods [J].
Zarra, T. ;
Naddeo, V. ;
Belgiorno, V. ;
Reiser, M. ;
Kranert, M. .
WATER SCIENCE AND TECHNOLOGY, 2009, 59 (08) :1603-1609