Is Bone Mineral Density Measurement Using Dual-Energy X-Ray Absorptiometry Affected by Gamma Rays?

被引:10
|
作者
Xie, Liang-Jun [1 ]
Li, Jian-Fang [1 ]
Zeng, Feng-Wei [1 ]
Jiang, Hang [1 ]
Cheng, Mu-Hua [1 ]
Chen, Yi [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 3, Dept Nucl Med, Guangzhou 510630, Guangdong, Peoples R China
关键词
Bone mineral density; dual-energy X-ray absorptiometry; gamma ray; radionuclide; MDP;
D O I
10.1016/j.jocd.2013.02.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objective of this study was to determine whether the gamma rays emitted from the radionuclide effect bone mineral density (BMD) measurement. Nine subjects (mean age: 56 +/- 17.96 yr) scheduled for bone scanning underwent BMD measurement using dual-energy X-ray absorptiometry (DXA) (Hologic/Discovery A) before and 1, 2, and 4 h after injection of technetium-99m-methylene diphosphonate (Tc-99m-MDP). Ten subjects (mean age: 41 +/- 15.47 yr) scheduled for therapy of differentiated thyroid carcinoma with iodine-131 underwent BMD measurement before and 2 h after therapeutic radionuclide administration. All patients were given whole body BMD measurement, including head, arm, ribs, lumbar spine, pelvis, and leg sites. Besides, patients who referred to radioiodine therapy were given total hip and femoral neck BMD measurement as well. No statistically significant changes in BMD values were detected after Tc-99m-MDP and iodine-131 administration for all measurement sites (p > 0.05), and individual difference of BMD before and after radionuclide imaging or therapy was less than the least significant change in lumbar spine, total hip, and femoral neck. In conclusion, BMD measurements are not influenced by the gamma rays emitted from technetium-99m and iodine-131. DXA bone densitometry may be performed simultaneously with bone scanning and radioiodine therapy.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 50 条
  • [41] BONE-MINERAL DENSITY IN FELINE MUCOPOLYSACCHARIDOSIS-VI MEASURED USING DUAL-ENERGY X-RAY ABSORPTIOMETRY
    TURNER, AS
    NORRDIN, RW
    GAARDE, S
    CONNALLY, HE
    THRALL, MA
    CALCIFIED TISSUE INTERNATIONAL, 1995, 57 (03) : 191 - 195
  • [42] Assessment of bone mineral density by dual energy x-ray absorptiometry in patients with mucopolysaccharidoses
    Lin, Hsiang-Yu
    Shih, Shou-Chuan
    Chuang, Chih-Kuang
    Chen, Ming-Ren
    Niu, Dau-Ming
    Lin, Shuan-Pei
    ORPHANET JOURNAL OF RARE DISEASES, 2013, 8
  • [43] Reliability of analysis of the bone mineral density of the second and fifth metatarsals using dual-energy x-ray absorptiometry (DXA)
    N. Stewart Pritchard
    James M. Smoliga
    Anh-Dung Nguyen
    Micah C. Branscomb
    David R. Sinacore
    Jeffrey B. Taylor
    Kevin R. Ford
    Journal of Foot and Ankle Research, 10
  • [44] Mesurement of bone density in adult cats using Dual-Energy X-ray Absorptiometry (DEXA)
    Schmidt, J
    Fehr, M
    Viguier, E
    KLEINTIERPRAXIS, 2006, 51 (04): : 205 - 209
  • [45] REPRODUCIBILITY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY
    CHILIBECK, P
    CALDER, A
    SALE, DG
    WEBBER, C
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1994, 45 (04): : 297 - 302
  • [46] Validation of peripheral dual-energy X-ray absorptiometry for the measurement of bone mineral in intact and excised long bones of rats
    Nagy, TR
    Prince, CW
    Li, J
    JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (09) : 1682 - 1687
  • [47] The Effect of Neck Flexion on Measurement of Spinal Bone Mineral Density and the Need to Apply Head Positioners During Dual-Energy X-Ray Absorptiometry
    Qutbi, Mohsen
    Ghanbari, Saj Ad
    Soltanshahi, Mehdi
    Gorzi, Saba Karami
    Shiravand, Yaser
    Ranji, Shahla
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2020, 48 (04) : 340 - 343
  • [48] Monitoring of dual-energy X-ray absorptiometry measurement in clinical practice
    El Maghraoui, Abdellah
    Achemlal, Lahsen
    Bezza, Ahmed
    JOURNAL OF CLINICAL DENSITOMETRY, 2006, 9 (03) : 281 - 286
  • [49] Intervals between bone mineral density testing with dual-energy X-ray absorptiometry scans in clinical practice
    H. Lyu
    K. Yoshida
    S.K. Tedeschi
    S. Zhao
    C. Xu
    S.U. Nigwekar
    B.Z. Leder
    D.H. Solomon
    Osteoporosis International, 2019, 30 : 923 - 927
  • [50] Evaluation of bone mineral density of the lumbar spine using a novel phantomless dual-energy CT post-processing algorithm in comparison with dual-energy X-ray absorptiometry
    Booz C.
    Hofmann P.C.
    Sedlmair M.
    Flohr T.G.
    Schmidt B.
    D’Angelo T.
    Martin S.S.
    Lenga L.
    Leithner D.
    Vogl T.J.
    Wichmann J.L.
    European Radiology Experimental, 1 (1)