Is Bone Mineral Density Measurement Using Dual-Energy X-Ray Absorptiometry Affected by Gamma Rays?

被引:10
作者
Xie, Liang-Jun [1 ]
Li, Jian-Fang [1 ]
Zeng, Feng-Wei [1 ]
Jiang, Hang [1 ]
Cheng, Mu-Hua [1 ]
Chen, Yi [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 3, Dept Nucl Med, Guangzhou 510630, Guangdong, Peoples R China
关键词
Bone mineral density; dual-energy X-ray absorptiometry; gamma ray; radionuclide; MDP;
D O I
10.1016/j.jocd.2013.02.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objective of this study was to determine whether the gamma rays emitted from the radionuclide effect bone mineral density (BMD) measurement. Nine subjects (mean age: 56 +/- 17.96 yr) scheduled for bone scanning underwent BMD measurement using dual-energy X-ray absorptiometry (DXA) (Hologic/Discovery A) before and 1, 2, and 4 h after injection of technetium-99m-methylene diphosphonate (Tc-99m-MDP). Ten subjects (mean age: 41 +/- 15.47 yr) scheduled for therapy of differentiated thyroid carcinoma with iodine-131 underwent BMD measurement before and 2 h after therapeutic radionuclide administration. All patients were given whole body BMD measurement, including head, arm, ribs, lumbar spine, pelvis, and leg sites. Besides, patients who referred to radioiodine therapy were given total hip and femoral neck BMD measurement as well. No statistically significant changes in BMD values were detected after Tc-99m-MDP and iodine-131 administration for all measurement sites (p > 0.05), and individual difference of BMD before and after radionuclide imaging or therapy was less than the least significant change in lumbar spine, total hip, and femoral neck. In conclusion, BMD measurements are not influenced by the gamma rays emitted from technetium-99m and iodine-131. DXA bone densitometry may be performed simultaneously with bone scanning and radioiodine therapy.
引用
收藏
页码:275 / 278
页数:4
相关论文
共 15 条
[1]  
[Anonymous], 2001, South Med J, V94, P569
[2]   Technical principles of dual energy x-ray absorptiometry [J].
Blake, GM ;
Fogelman, I .
SEMINARS IN NUCLEAR MEDICINE, 1997, 27 (03) :210-228
[3]   Effect of 99mTc-MDP adminstration on dual-energy X-ray absorptiometry bone mineral density measurements [J].
Campbell, A ;
McCarthy, M ;
Blake, M ;
Roff, G .
JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (01) :14-17
[4]   Artifactual reduction in bone density as a result of technetium-99m MDP for bone scanning -: Report of two cases [J].
Chan, PS ;
Binkley, NC ;
Lalande, BM ;
Young, S ;
Shaker, JL .
JOURNAL OF CLINICAL DENSITOMETRY, 2004, 7 (04) :457-458
[5]   Property of a CZT Semiconductor Detector for Radionuclide Identification [J].
Chun, Sung-Dae ;
Park, Se-Hwan ;
Lee, Dong Hoon ;
Kim, Yong Kyun ;
Ha, Jang Ho ;
Kang, Sang Mook ;
Cho, Yun Ho ;
Hong, Duk-Geun ;
Kim, Jong Kyung .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, :421-424
[6]   Improved x-ray spectroscopy with room temperature CZT detectors [J].
Fritz, Shannon G. ;
Shikhaliev, Polad M. ;
Matthews, Kenneth L., II .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17) :5735-5751
[7]  
Goddard space flight center, SCINT GAMM RAY DET
[8]   Effects of 99mTc-MIBI and 99mTc-MDP administration on dual-energy X-ray absorptiometry bone mineral density measurements [J].
Gumuser, Gul ;
Parlak, Yasemin ;
Topal, Gokcen ;
Aras, Feray ;
Ruksen, Ebru .
NUCLEAR MEDICINE COMMUNICATIONS, 2009, 30 (06) :445-448
[9]  
Hologic, 1997, QDR 4500 FAN BEAM XR
[10]   Pencil-beam versus fan-beam dual-energy X-ray absorptiometry comparisons across four systems: appendicular lean soft tissue [J].
Ioannidou, E ;
Padilla, J ;
Wang, J ;
Heymsfield, SB ;
Thornton, JC ;
Horlick, M ;
Gallagher, D ;
Pierson, RN .
ACTA DIABETOLOGICA, 2003, 40 (Suppl 1) :S83-S85