In vivo comparison of myocardial T1 with T2 and T2*in thalassaemia major

被引:58
作者
Feng, Yanqiu [1 ,2 ]
He, Taigang [2 ,3 ]
Carpenter, John-Paul [2 ,3 ]
Jabbour, Andrew [2 ,3 ]
Alam, Mohammed Harith [2 ,3 ]
Gatehouse, Peter D. [2 ,3 ]
Greiser, Andreas [4 ]
Messroghli, Daniel [5 ]
Firmin, David N. [2 ,3 ]
Pennell, Dudley J. [2 ,3 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou, Peoples R China
[2] Royal Brompton Hosp, Cardiovasc Magnet Resonance Unit, London SW3 6NP, England
[3] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, London, England
[4] Siemens AG, Healthcare Sect, Erlangen, Germany
[5] Deutsch Herzzentrum Berlin, Dept Congenital Heart Dis & Pediat Cardiol, Berlin, Germany
关键词
MRI relaxometry; T2*; T2; T1; tissue characterization; myocardium; T2-ASTERISK-CARDIOVASCULAR MAGNETIC-RESONANCE; INVERSION-RECOVERY MOLLI; IRON; RESOLUTION; DIAGNOSIS; SURVIVAL;
D O I
10.1002/jmri.24010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare myocardial T1 against T2 and T2* in patients with thalassemia major (TM) for myocardial iron characterization. Materials and Methods: A total of 106 TM patients (29 +/- 10 years; 58 males) were studied on a 1.5 Tesla scanner using dedicated T1, T2*, and T2 relaxometry sequences. A single mid-ventricular short axis slice was acquired within a breath-hold. Results: In patients with myocardial iron overload (T2* < 20 ms; n = 52), there were linear correlations between T2 and T2* (r = 0.82; P = 0.0), and between T1 and T2* (r = 0.83; P = 0.0). In patients with no myocardial iron (n = 54), T2* values were scattered with no significant correlation against T2 or T1. For all patients (n = 106) there was a strong linear correlation (r = 0.93; P = 0.0) between myocardial T1 and T2. Conclusion: In patients with iron overload, myocardial T2 and T1 are correlated with T2*. In patients with low or normal myocardial iron concentration, other factors become dominant in affecting T2* values as shown by scattered T2* data. Myocardial T1 correlates linearly with T2 measurements in all patients suggesting that these two relaxation parameters avoid extrinsic magnetic field inhomogeneity effects and may potentially provide improved myocardial tissue characterization. J. Magn. Reson. Imaging 2013;38:588-593. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:588 / 593
页数:6
相关论文
共 24 条
[1]   A pilot trial of deferiprone for neurodegeneration with brain iron accumulation [J].
Abbruzzese, Giovanni ;
Cossu, Giovanni ;
Balocco, Manuela ;
Marchese, Roberta ;
Murgia, Daniela ;
Melis, Maurizio ;
Galanello, Renzo ;
Barella, Susanna ;
Matta, Gildo ;
Ruffinengo, Uberto ;
Bonuccelli, Ubaldo ;
Forni, Gian Luca .
HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2011, 96 (11) :1708-1711
[2]   Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload [J].
Anderson, LJ ;
Holden, S ;
Davis, B ;
Prescott, E ;
Charrier, CC ;
Bunce, NH ;
Firmin, DN ;
Wonke, B ;
Porter, J ;
Walker, JM ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2001, 22 (23) :2171-2179
[3]   Survival and disease complications in thalassemia major [J].
Borgna-Pignatti, C ;
Rugolotto, S ;
De Stefano, P ;
Piga, A ;
Di Gregorio, F ;
Gamberini, MR ;
Sabato, V ;
Melevendi, C ;
Cappellini, MD ;
Verlato, G .
COOLEYS ANEMIA: SEVENTH SYMPOSIUM, 1998, 850 :227-231
[4]   On T2*Magnetic Resonance and Cardiac Iron [J].
Carpenter, John-Paul ;
He, Taigang ;
Kirk, Paul ;
Roughton, Michael ;
Anderson, Lisa J. ;
de Noronha, Sofia V. ;
Sheppard, Mary N. ;
Porter, John B. ;
Walker, J. Malcolm ;
Wood, John C. ;
Galanello, Renzo ;
Forni, Gianluca ;
Catani, Gualtiero ;
Matta, Gildo ;
Fucharoen, Suthat ;
Fleming, Adam ;
House, Michael J. ;
Black, Greg ;
Firmin, David N. ;
St Pierre, Timothy G. ;
Pennell, Dudley J. .
CIRCULATION, 2011, 123 (14) :1519-1528
[5]   LIVER IRON QUANTIFICATION - STUDIES IN AQUEOUS IRON SOLUTIONS, IRON-OVERLOADED RATS, AND PATIENTS WITH HEREDITARY HEMOCHROMATOSIS [J].
ENGELHARDT, R ;
LANGKOWSKI, JH ;
FISCHER, R ;
NIELSEN, P ;
KOOIJMAN, H ;
HEINRICH, HC ;
BUCHELER, E .
MAGNETIC RESONANCE IMAGING, 1994, 12 (07) :999-1007
[6]   Corrected equations for susceptibility-induced T2-shortening [J].
Gillis, P ;
Roch, A ;
Brooks, RA .
JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (02) :402-407
[7]   Automated truncation method for myocardial T2* measurement in thalassemia [J].
He, Taigang ;
Zhang, Jun ;
Carpenter, John-Paul ;
Feng, Yanqiu ;
Smith, Gillian C. ;
Pennell, Dudley J. ;
Firmin, David N. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (02) :479-483
[8]   Black-blood T2*technique for myocardial iron measurement in thalassemia [J].
He, Taigang ;
Gatehouse, Peter D. ;
Kirk, Paul ;
Tanner, Mark A. ;
Smith, Gillian C. ;
Keegan, Jennifer ;
Mohiaddin, Raad H. ;
Pennell, Dudley J. ;
Firmin, David N. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (06) :1205-1209
[9]   Development of a novel optimized breathhold technique for myocardial T2 measurement in thalassemia [J].
He, Taigang ;
Gatehouse, Peter D. ;
Anderson, Lisa J. ;
Tanner, Mark ;
Keegan, Jennifer ;
Pennell, Dudley J. ;
Firmin, David N. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (03) :580-585
[10]   On Using T2 to Assess Extrinsic Magnetic Field Inhomogeneity Effects Myocardial Siderosis on T2* Measurements in in Thalassemia [J].
He, Taigang ;
Smith, Gillian C. ;
Gatehouse, Peter D. ;
Mohiaddin, Raad H. ;
Firmin, David N. ;
Pennell, Dudley J. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (03) :501-506