Hybrid Assessment of Myocardial Ischemia Using Stress-Only Nuclear Myocardial Perfusion Imaging and Rest Computed Tomography Perfusion Imaging

被引:0
|
作者
Suzuki, Yasuyuki [1 ]
Matsumoto, Naoya [1 ]
Makita, Ayano [1 ]
Ashida, Tadashi [1 ]
Kuronuma, Keiichiro [1 ]
Amano, Yasuo [2 ]
Yoda, Shunichi [3 ]
Okumura, Yasuo [3 ]
机构
[1] Nihon Univ Hosp, Dept Cardiol, Tokyo, Japan
[2] Nihon Univ Hosp, Dept Radiol, Tokyo, Japan
[3] Nihon Univ, Dept Med, Div Cardiol, Sch Med, Tokyo, Japan
关键词
Myocardial perfusion imaging; Multidetector computed tomography; Semiconductor gamma camera; Stress-only nuclear myocardial perfusion imaging; CORONARY-ARTERY-DISEASE; PROGNOSTIC VALUE; SEPARATE ACQUISITION; CT ANGIOGRAPHY; CARDIOLOGY; SOCIETY; QUANTIFICATION; ASSOCIATION; PERFORMANCE; GUIDELINES;
D O I
10.1253/circj.CJ-20-0499
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Sequential assessment using CT coronary angiography (coronary CT) and nuclear myocardial perfusion imaging (MPI) is considered an anatomical and functional evaluation of coronary artery disease (CAD). However, there can be unexpected radiation exposure. Hybrid MPI with stress-only nuclear MPI and rest CT-MPI using coronary CT may contribute to reducing the radiation dose in sequential assessment with nuclear MPI after coronary CT. We analyzed the diagnostic performance and total radiation dose of hybrid MPI for detection of significant CAD compared with sequential assessment using nuclear MPI after coronary CT. Methods and Results: The results for 101 patients who underwent coronary CT, nuclear MPI and invasive coronary angiography within 3 months of all imaging were analyzed. We calculated the summed difference score (SDS) from standard nuclear MPI and hybrid SDS from hybrid MPI, which revealed myocardial ischemia. The diagnostic performance of SDS and hybrid SDS for detecting significant CAD was analyzed using receiver-operating characteristic (ROC) curve analysis. We also compared the total radiation dose of both methods. The area under the ROC curve was not different between SDS and hybrid SDS (0.901 and 0.815, P=0.079). Total radiation dose of hybrid MPI was significantly lower than standard nuclear MPI with CT angiography (4.62 mSv vs. 9.72 mSv, P<0.0001). Conclusions: Hybrid MPI showed a precise diagnostic accuracy for significant CAD detection.
引用
收藏
页码:1818 / 1825
页数:8
相关论文
共 50 条
  • [31] Prediction of multivessel coronary artery disease and candidates for stress-only imaging using multivariable models with myocardial perfusion imaging
    Yuji Kunita
    Kenichi Nakajima
    Tomoaki Nakata
    Takashi Kudo
    Seigo Kinuya
    Annals of Nuclear Medicine, 2022, 36 : 674 - 683
  • [32] Stress only myocardial perfusion imaging: Is it time for a change?
    John J. Mahmarian
    Journal of Nuclear Cardiology, 2010, 17 : 529 - 535
  • [33] Possibilities of Stress Computed Tomography Myocardial Perfusion Imaging in the Diagnosis of Ischemic Heart Disease
    Omarov, Y. A.
    Sukhinina, T. S.
    Veselova, T. N.
    Shakhnovich, R. M.
    Zhukova, N. S.
    Merkulova, I. N.
    KARDIOLOGIYA, 2020, 60 (10) : 122 - 131
  • [34] The prognosis of a normal stress-only Tc-99m myocardial perfusion imaging study
    Duvall, W. Lane
    Wijetunga, Melanie N.
    Klein, Thomas M.
    Razzouk, Louai
    Godbold, Jim
    Croft, Lori B.
    Henzlova, Milena J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (03) : 370 - 377
  • [35] Normal Stress-Only Versus Standard Stress/Rest Myocardial Perfusion Imaging Similar Patient Mortality With Reduced Radiation Exposure Reply
    Mahmarian, John J.
    Chang, Su Min
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (23) : 2612 - 2613
  • [36] Prognostic Value of Normal Stress-Only Technetium-99 m Myocardial Perfusion Imaging Protocol - Comparison With Standard Stress-Rest Protocol
    Ueyama, Takanao
    Takehana, Kazuya
    Maeba, Hirofumi
    Iwasaka, Toshiji
    CIRCULATION JOURNAL, 2012, 76 (10) : 2386 - 2391
  • [37] Optimizing stress-only myocardial perfusion imaging: a clinical prediction model to improve patient selection
    Martineau, Patrick J.
    Pelletier-Galarneau, Matthieu
    Slomka, Piotr
    Goertzen, Andrew L.
    Leslie, William D.
    NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (12) : 1087 - 1093
  • [38] Myocardial perfusion analysis in cardiac computed tomography angiographic images at rest
    Xiong, Guanglei
    Kola, Deeksha
    Heo, Ran
    Elmore, Kimberly
    Cho, Iksung
    Min, James K.
    MEDICAL IMAGE ANALYSIS, 2015, 24 (01) : 77 - 89
  • [39] Diagnostic Performance of Dynamic Myocardial Perfusion Imaging Using Dual-Source Computed Tomography
    Kitagawa, Kakuya
    Nakamura, Satoshi
    Ota, Hideki
    Ogawa, Ryo
    Shizuka, Takehito
    Kubo, Tadahiro
    Yi, Yan
    Ito, Tatsuro
    Nagasawa, Naoki
    Omori, Taku
    Nakamori, Shiro
    Kurita, Tairo
    Sugisawa, Jun
    Hatori, Naoki
    Nakashima, Hitoshi
    Wang, Yining
    Kido, Teruhito
    Watanabe, Kouki
    Matsumoto, Yasuharu
    Dohi, Kaoru
    Sakuma, Hajime
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (20) : 1937 - 1949