Hybrid Assessment of Myocardial Ischemia Using Stress-Only Nuclear Myocardial Perfusion Imaging and Rest Computed Tomography Perfusion Imaging

被引:0
|
作者
Suzuki, Yasuyuki [1 ]
Matsumoto, Naoya [1 ]
Makita, Ayano [1 ]
Ashida, Tadashi [1 ]
Kuronuma, Keiichiro [1 ]
Amano, Yasuo [2 ]
Yoda, Shunichi [3 ]
Okumura, Yasuo [3 ]
机构
[1] Nihon Univ Hosp, Dept Cardiol, Tokyo, Japan
[2] Nihon Univ Hosp, Dept Radiol, Tokyo, Japan
[3] Nihon Univ, Dept Med, Div Cardiol, Sch Med, Tokyo, Japan
关键词
Myocardial perfusion imaging; Multidetector computed tomography; Semiconductor gamma camera; Stress-only nuclear myocardial perfusion imaging; CORONARY-ARTERY-DISEASE; PROGNOSTIC VALUE; SEPARATE ACQUISITION; CT ANGIOGRAPHY; CARDIOLOGY; SOCIETY; QUANTIFICATION; ASSOCIATION; PERFORMANCE; GUIDELINES;
D O I
10.1253/circj.CJ-20-0499
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Sequential assessment using CT coronary angiography (coronary CT) and nuclear myocardial perfusion imaging (MPI) is considered an anatomical and functional evaluation of coronary artery disease (CAD). However, there can be unexpected radiation exposure. Hybrid MPI with stress-only nuclear MPI and rest CT-MPI using coronary CT may contribute to reducing the radiation dose in sequential assessment with nuclear MPI after coronary CT. We analyzed the diagnostic performance and total radiation dose of hybrid MPI for detection of significant CAD compared with sequential assessment using nuclear MPI after coronary CT. Methods and Results: The results for 101 patients who underwent coronary CT, nuclear MPI and invasive coronary angiography within 3 months of all imaging were analyzed. We calculated the summed difference score (SDS) from standard nuclear MPI and hybrid SDS from hybrid MPI, which revealed myocardial ischemia. The diagnostic performance of SDS and hybrid SDS for detecting significant CAD was analyzed using receiver-operating characteristic (ROC) curve analysis. We also compared the total radiation dose of both methods. The area under the ROC curve was not different between SDS and hybrid SDS (0.901 and 0.815, P=0.079). Total radiation dose of hybrid MPI was significantly lower than standard nuclear MPI with CT angiography (4.62 mSv vs. 9.72 mSv, P<0.0001). Conclusions: Hybrid MPI showed a precise diagnostic accuracy for significant CAD detection.
引用
收藏
页码:1818 / 1825
页数:8
相关论文
共 50 条
  • [21] Assessment of Cardiac Computed Tomography-Myocardial Perfusion Imaging - Promise and Challenges
    Dwivedi, Girish
    Dowsley, Taylor F.
    Chow, Benjamin J. W.
    CIRCULATION JOURNAL, 2012, 76 (03) : 544 - 552
  • [22] Stress Myocardial Perfusion Imaging by Computed Tomography A Dynamic Road Is Ahead
    Blankstein, Ron
    Jerosch-Herold, Michael
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (08) : 821 - 823
  • [23] Peak enhancement ratio of myocardium to aorta for identification of myocardial ischemia using dynamic myocardial computed tomography perfusion imaging
    Tanabe, Yuki
    Kido, Teruhito
    Kurata, Akira
    Yokoi, Takahiro
    Fukuyama, Naoki
    Uetani, Teruyoshi
    Nishiyama, Hikaru
    Kawaguchi, Naoto
    Tahir, Enver
    Miyagawa, Masao
    Mochizuki, Teruhito
    JOURNAL OF CARDIOLOGY, 2017, 70 (5-6) : 565 - 570
  • [24] Myocardial ischemia in patient with diabetes: Contributions of myocardial perfusion imaging
    Idir, M. Ait
    Guensi, A.
    Taleb, S.
    Chabraoui, F.
    Kebbou, M.
    Zoubidi, M. Z.
    Farouqi, M.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2013, 37 (12): : 569 - 577
  • [25] Myocardial computed tomography perfusion
    Branch, Kelley R.
    Haley, Ryan D.
    Bittencourt, Marcio Sommer
    Patel, Amit R.
    Hulten, Edward
    Blankstein, Ron
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2017, 7 (05) : 452 - 462
  • [26] The role of computed tomography myocardial perfusion imaging in clinical practice
    Singh, Amita
    Mor-Avi, Victor
    Patel, Amit R.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2020, 14 (02) : 185 - 194
  • [27] Myocardial Perfusion Imaging with Cardiac Computed Tomography: State of the Art
    Amit R. Patel
    Nicole M. Bhave
    Victor Mor-Avi
    Journal of Cardiovascular Translational Research, 2013, 6 : 695 - 707
  • [28] Myocardial Perfusion Imaging with Cardiac Computed Tomography: State of the Art
    Patel, Amit R.
    Bhave, Nicole M.
    Mor-Avi, Victor
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2013, 6 (05) : 695 - 707
  • [29] Prognosis of normal stress-only gated-SPECT myocardial perfusion imaging: a single center study
    Vidigal Ferreira, Maria Joao
    Cunha, Maria Joao
    Albuquerque, Anabela
    Moreira, Ana Paula
    Ramos, Domingos
    Costa, Gracinda
    Lima, Joao
    Pego, Mariano
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (07) : 1639 - 1644
  • [30] Prediction of multivessel coronary artery disease and candidates for stress-only imaging using multivariable models with myocardial perfusion imaging
    Kunita, Yuji
    Nakajima, Kenichi
    Nakata, Tomoaki
    Kudo, Takashi
    Kinuya, Seigo
    ANNALS OF NUCLEAR MEDICINE, 2022, 36 (07) : 674 - 683