Hybrid Assessment of Myocardial Ischemia Using Stress-Only Nuclear Myocardial Perfusion Imaging and Rest Computed Tomography Perfusion Imaging

被引:0
|
作者
Suzuki, Yasuyuki [1 ]
Matsumoto, Naoya [1 ]
Makita, Ayano [1 ]
Ashida, Tadashi [1 ]
Kuronuma, Keiichiro [1 ]
Amano, Yasuo [2 ]
Yoda, Shunichi [3 ]
Okumura, Yasuo [3 ]
机构
[1] Nihon Univ Hosp, Dept Cardiol, Tokyo, Japan
[2] Nihon Univ Hosp, Dept Radiol, Tokyo, Japan
[3] Nihon Univ, Dept Med, Div Cardiol, Sch Med, Tokyo, Japan
关键词
Myocardial perfusion imaging; Multidetector computed tomography; Semiconductor gamma camera; Stress-only nuclear myocardial perfusion imaging; CORONARY-ARTERY-DISEASE; PROGNOSTIC VALUE; SEPARATE ACQUISITION; CT ANGIOGRAPHY; CARDIOLOGY; SOCIETY; QUANTIFICATION; ASSOCIATION; PERFORMANCE; GUIDELINES;
D O I
10.1253/circj.CJ-20-0499
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Sequential assessment using CT coronary angiography (coronary CT) and nuclear myocardial perfusion imaging (MPI) is considered an anatomical and functional evaluation of coronary artery disease (CAD). However, there can be unexpected radiation exposure. Hybrid MPI with stress-only nuclear MPI and rest CT-MPI using coronary CT may contribute to reducing the radiation dose in sequential assessment with nuclear MPI after coronary CT. We analyzed the diagnostic performance and total radiation dose of hybrid MPI for detection of significant CAD compared with sequential assessment using nuclear MPI after coronary CT. Methods and Results: The results for 101 patients who underwent coronary CT, nuclear MPI and invasive coronary angiography within 3 months of all imaging were analyzed. We calculated the summed difference score (SDS) from standard nuclear MPI and hybrid SDS from hybrid MPI, which revealed myocardial ischemia. The diagnostic performance of SDS and hybrid SDS for detecting significant CAD was analyzed using receiver-operating characteristic (ROC) curve analysis. We also compared the total radiation dose of both methods. The area under the ROC curve was not different between SDS and hybrid SDS (0.901 and 0.815, P=0.079). Total radiation dose of hybrid MPI was significantly lower than standard nuclear MPI with CT angiography (4.62 mSv vs. 9.72 mSv, P<0.0001). Conclusions: Hybrid MPI showed a precise diagnostic accuracy for significant CAD detection.
引用
收藏
页码:1818 / 1825
页数:8
相关论文
共 50 条
  • [1] Stress-only SPECT myocardial perfusion imaging: A review
    Gowd, B. M. Pampana
    Heller, Gary V.
    Parker, Matthew W.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (06) : 1200 - 1212
  • [2] Application of stress-only myocardial perfusion imaging
    Wlodarczyk, Michal
    Kusmierek, Jacek
    Bienkiewicz, Malgorzata
    Filipczak, Krzysztof
    Plachcinska, Anna
    NUCLEAR MEDICINE REVIEW, 2019, 22 (02) : 74 - 80
  • [3] Stress-Only SPECT Myocardial Perfusion Imaging for All?
    Hendel, Robert C.
    Crawford, Michael J.
    JACC-CARDIOVASCULAR IMAGING, 2020, 13 (10) : 2203 - 2205
  • [4] Stress-Only Myocardial Perfusion Imaging A New Paradigm
    Iskandrian, Ami E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (03) : 231 - 233
  • [5] Prognosis of stress-only SPECT myocardial perfusion imaging with prone imaging
    Gutstein, Ariel
    Bental, Tamir
    Solodky, Ajejandro
    Mats, Israel
    Zafrir, Nili
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (03) : 809 - 816
  • [6] Low-dose stress-only myocardial perfusion imaging
    Oruc, Vedran
    Hage, Fadi G.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (02) : 558 - 561
  • [7] Impact of the ISCHEMIA Trial on Stress Nuclear Myocardial Perfusion Imaging
    Murthy, Venkatesh L.
    Bateman, Timothy M.
    Chen, Wengen
    Malhotra, Saurabh
    Miller, Edward J.
    Ruddy, Terrence D.
    Dilsizian, Vasken
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (07) : 962 - 964
  • [8] Cost-Effectiveness of stress-only myocardial perfusion single photon emission computed tomography (SPECT) imaging
    Vallejo, Enrique
    Acevedo, Cesar
    Varela, Samuel
    Carlos Alburez, Jose
    Bialostozky, David
    GACETA MEDICA DE MEXICO, 2012, 148 (01): : 6 - 13
  • [9] Assessment of myocardial viability using single-photon emission computed tomography myocardial perfusion imaging
    Malhotra, Saurabh
    Gomez, Javier
    Doukky, Rami
    CURRENT OPINION IN CARDIOLOGY, 2019, 34 (05) : 473 - 483
  • [10] Value of multidetector computed tomography evaluation of myocardial perfusion in the assessment of ischemic heart disease: comparison with nuclear perfusion imaging
    Kachenoura, Nadjia
    Lodato, Joseph A.
    Gaspar, Tamar
    Bardo, Dianna M. E.
    Newby, Barbara
    Gips, Sarah
    Peled, Nathan
    Lang, Roberto M.
    Mor-Avi, Victor
    EUROPEAN RADIOLOGY, 2009, 19 (08) : 1897 - 1905