Accuracy of Conventional and Digital Methods of Obtaining Full-Arch Dental Impression (In Vitro Study)

被引:4
作者
Husein, Hassan A. [1 ]
Morad, Mhd. Luai [1 ]
Kanout, Shaza [1 ]
机构
[1] Damascus Univ, Fac Med Dent, Dept Fixed Prosthodont, Damascus, Syria
关键词
extra-oral scanner; 3d model; digital impression; conventional impression; intra-oral scanner; MODELS; TIME;
D O I
10.7759/cureus.29055
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The current gold standard is a conventional impression made with various impression materials and trays and results in a gypsum cast. With the development of milling and printing materials in dentistry, especially zirconia, a digital model has become increasingly important. Objectives To compare the accuracy of the conventional impression scan (CIS), gypsum cast scan (GCS), and digital impression scan (DIS) to obtain a full-arch digital model. Materials and methods A resin reference cast was fabricated. It was scanned by an extra-oral scanner to measure its accuracy as a reference scanner. Eight conventional impressions of the reference cast were taken by polyvinyl siloxane and scanned. After that, they were poured with type IV dental stones and scanned too. The reference cast was scanned by an intraoral scanner eight separate times. Digital models within each group were superimposed individually to measure precision. In addition, each model from each group was superimposed on one model from the reference scanner precision group to measure trueness. Results The reference scanner showed the highest accuracy among groups with a precision of 1.5 +/- 0.8 mu m and a trueness of 5.5 +/- 1.9 mu m (P<0.006), while precision values of gypsum cast were 8.1 +/- 1.7 mu m and trueness values were 9.3 +/- 2.6 mu m (P<0.012). Conventional impressions showed a precision of 14.06 +/- 2.01 mu m and a trueness of 16.15 +/- 2.07 mu m (P<0.012). Digital impressions were the least accurate among the groups, as precision values were 38.22 +/- 15.23 mu m and trueness values were 35.19 +/- 8.7 mu m (P<0.006). Conclusion The gypsum cast scans showed the highest accuracy, followed by the conventional impression scans, and finally the digital impression scans, with no clinical significance.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Comparing the accuracy of full-arch implant impressions using the conventional technique and digital scans with and without prefabricated landmarks in the mandible: An in vitro study
    Ke, Yifang
    Zhang, Yaopeng
    Wang, Yong
    Chen, Hu
    Sun, Yuchun
    JOURNAL OF DENTISTRY, 2023, 135
  • [22] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Francesco Guido Mangano
    Oleg Admakin
    Matteo Bonacina
    Henriette Lerner
    Vygandas Rutkunas
    Carlo Mangano
    BMC Oral Health, 20
  • [23] Evaluation of hypermobile teeth deviation during impression taking in a partially edentulous dental arch: An in vitro study comparing digital and conventional impression techniques
    Matsuno, Hitomi
    Wada, Junichiro
    Murakami, Natsuko
    Takakusaki, Kensuke
    Nagayama, Tomiharu
    Manabe, Kaho
    Nomura, Yugo
    Koyama, Shinsuke
    Mouri, Yuki
    Li, Bin
    Sakamoto, Kazuki
    Kim, Eung-Yeol
    Ishioka, Yurika
    Utsumi, Miona
    Wakabayashi, Noriyuki
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024, : 259 - 266
  • [24] Accuracy of digital and conventional implant-level impression techniques for maxillary full-arch screw-retained prosthesis: A crossover randomized trial
    Jasim, Ammar Ghanim
    Abo Elezz, Mona Galal
    Altonbary, Gilan Y.
    Elsyad, Moustafa Abdou
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (04) : 714 - 723
  • [25] Accuracy of full-arch scans using intraoral and extraoral scanners: an in vitro study using a new method of evaluation
    Muallah, J.
    Wesemann, C.
    Nowak, R.
    Robben, J.
    Mah, J.
    Pospiech, P.
    Bumann, A.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2017, 20 (02) : 151 - 164
  • [26] Accuracy of Full-Arch Intraoral Scans Versus Conventional Impression: A Systematic Review with a Meta-Analysis and a Proposal to Standardise the Analysis of the Accuracy
    Pesce, Paolo
    Nicolini, Paolo
    Caponio, Vito Carlo Alberto
    Zecca, Piero Antonio
    Canullo, Luigi
    Isola, Gaetano
    Baldi, Domenico
    De Angelis, Nicola
    Menini, Maria
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (01)
  • [27] An in-vitro study comparing the accuracy of full-arch casts digitized with desktop scanners
    Nowak, Roxana
    Wesemann, Christian
    Robben, Jan
    Muallah, Jonas
    Bumann, Axel
    QUINTESSENCE INTERNATIONAL, 2017, 48 (08): : 667 - 676
  • [28] Accuracy of Master Casts Generated Using Conventional and Digital Impression Modalities: Part 2-The Full Arch Dimension
    Sayed, Mohammed E.
    Al-Mansour, Hosain
    Alshehri, Abdulkarim Hussain
    Al-Sanabani, Fuad
    Al-Makramani, Bandar M. A.
    Mugri, Maryam Hassan
    Ahmed, Walaa Magdy
    Alqahtani, Nasser M.
    Bukhary, Dalea Mohammed
    Alsurayyie, Fatimah H.
    Shaabi, Fawzia Ibraheem
    Akkam, Yasir Yahya
    Hakami, Hanan Ibrahim
    Jain, Saurabh
    APPLIED SCIENCES-BASEL, 2022, 12 (04):
  • [29] Assessment of Fit on Ten Screw-Retained FrameworksRealized through Digital Full-Arch Implant Impression
    De Francesco, Maurizio
    Stellini, Edoardo
    Granata, Stefano
    Mazzoleni, Sergio
    Ludovichetti, Francesco Saverio
    Monaco, Carlo
    Di Fiore, Adolfo
    APPLIED SCIENCES-BASEL, 2021, 11 (12):
  • [30] Accuracy of full-arch scans using intraoral scanners
    Patzelt, Sebastian B. M.
    Emmanouilidi, Archontia
    Stampf, Susanne
    Strub, Joerg R.
    Att, Wael
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (06) : 1687 - 1694