Accuracy of Conventional and Digital Methods of Obtaining Full-Arch Dental Impression (In Vitro Study)

被引:4
|
作者
Husein, Hassan A. [1 ]
Morad, Mhd. Luai [1 ]
Kanout, Shaza [1 ]
机构
[1] Damascus Univ, Fac Med Dent, Dept Fixed Prosthodont, Damascus, Syria
关键词
extra-oral scanner; 3d model; digital impression; conventional impression; intra-oral scanner; MODELS; TIME;
D O I
10.7759/cureus.29055
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The current gold standard is a conventional impression made with various impression materials and trays and results in a gypsum cast. With the development of milling and printing materials in dentistry, especially zirconia, a digital model has become increasingly important. Objectives To compare the accuracy of the conventional impression scan (CIS), gypsum cast scan (GCS), and digital impression scan (DIS) to obtain a full-arch digital model. Materials and methods A resin reference cast was fabricated. It was scanned by an extra-oral scanner to measure its accuracy as a reference scanner. Eight conventional impressions of the reference cast were taken by polyvinyl siloxane and scanned. After that, they were poured with type IV dental stones and scanned too. The reference cast was scanned by an intraoral scanner eight separate times. Digital models within each group were superimposed individually to measure precision. In addition, each model from each group was superimposed on one model from the reference scanner precision group to measure trueness. Results The reference scanner showed the highest accuracy among groups with a precision of 1.5 +/- 0.8 mu m and a trueness of 5.5 +/- 1.9 mu m (P<0.006), while precision values of gypsum cast were 8.1 +/- 1.7 mu m and trueness values were 9.3 +/- 2.6 mu m (P<0.012). Conventional impressions showed a precision of 14.06 +/- 2.01 mu m and a trueness of 16.15 +/- 2.07 mu m (P<0.012). Digital impressions were the least accurate among the groups, as precision values were 38.22 +/- 15.23 mu m and trueness values were 35.19 +/- 8.7 mu m (P<0.006). Conclusion The gypsum cast scans showed the highest accuracy, followed by the conventional impression scans, and finally the digital impression scans, with no clinical significance.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions
    Ender, Andreas
    Mehl, Albert
    QUINTESSENCE INTERNATIONAL, 2015, 46 (01): : 9 - 17
  • [2] Trueness of full-arch dental models obtained by digital and conventional impression techniques: an in vivo study
    Yonca Onbasi
    Sabrin Abu-Hossin
    Maria Paulig
    Lara Berger
    Manfred Wichmann
    Ragai-Edward Matta
    Scientific Reports, 12 (1)
  • [3] Trueness of full-arch dental models obtained by digital and conventional impression techniques: an in vivo study
    Onbasi, Yonca
    Abu-Hossin, Sabrin
    Paulig, Maria
    Berger, Lara
    Wichmann, Manfred
    Matta, Ragai-Edward
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [4] Comparison of the accuracy between full-arch digital scans and scannable impression materials: an in vitro study
    Grande, Francesco
    Celeghin, Giordano
    Gallinaro, Federica
    Mobilio, Nicola
    Catapano, Santo
    MINERVA DENTAL AND ORAL SCIENCE, 2023, 72 (04) : 168 - 175
  • [5] Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study
    Drancourt, Noemie
    Auduc, Chantal
    Mouget, Aymeric
    Mouminoux, Jean
    Auroy, Pascal
    Veyrune, Jean-Luc
    El Osta, Nada
    Nicolas, Emmanuel
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [6] Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation
    Pesce, Paolo
    Pera, Francesco
    Setti, Paolo
    Menini, Maria
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (02) : 171 - 175
  • [7] In Vitro Accuracy of Digital and Conventional Impressions for Full-Arch Implant-Supported Prostheses
    D'haese, Rani
    Vrombaut, Tom
    Roeykens, Herman
    Vandeweghe, Stefan
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [8] Investigation of the Accuracy of Four Intraoral Scanners in Mandibular Full-Arch Digital Implant Impression: A Comparative In Vitro Study
    Di Fiore, Adolfo
    Graiff, Lorenzo
    Savio, Gianpaolo
    Granata, Stefano
    Basilicata, Michele
    Bollero, Patrizio
    Meneghello, Roberto
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (08)
  • [9] Accuracy of Digital and Conventional Full-Arch Impressions in Patients: An Update
    Schmidt, Alexander
    Klussmann, Leona
    Woestmann, Bernd
    Schlenz, Maximiliane Amelie
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (03)
  • [10] Full-Arch Digital Implant Impression Trueness: An in Vivo Study
    Rutkunas, Vygandas
    Kules, Daniel
    Revilla-Leon, Marta
    Akulauskas, Mykolas
    Auskalnis, Liudas
    Gendviliene, Ieva
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,