Numerical simulation of turbulent plume spread in ceiling vented enclosure

被引:22
作者
Harish, R. [1 ]
Venkatasubbaiah, K. [1 ]
机构
[1] Indian Inst Technol Hyderabad, Dept Mech Engn, Hyderabad 502205, Andhra Pradesh, India
关键词
Thermal plume; Partial enclosures; Ceiling vents; Grashof number; FIRE-INDUCED FLOW; NATURAL-CONVECTION; SQUARE CAVITY; PREDICT; DRIVEN; SMOKE; RANS;
D O I
10.1016/j.euromechflu.2013.06.001
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The buoyancy-induced turbulent flow generated by a heat source in a square enclosure with single and multiple ceiling vents has been studied numerically. A two-dimensional, turbulent natural convection flow is investigated in stream function and vorticity formulation approach. A low Reynolds number k-epsilon turbulence model of Lam Bremhorst is used to solve the governing equations using high accuracy compact finite difference schemes. Results are reported for different Grashof numbers varied from 10(8) to 10(10). The effects of heat source location, vent location and multiple vents on flow characteristics in enclosure are presented. The heat transfer characteristics, ambient entrainment flow rate and the oscillatory nature of the penetrative and recirculating flow inside the vented enclosure are reported. The results indicate significant change in the flow behavior by varying the location of heat source and vent for fixed Grashof number. The effect of entrainment of ambient air is significant with increase in Grashof number. The volume flow rates through the two ceiling vents showed a significant variation depending on the location of vent. Present results are matching very well with the experimental and numerical results available from the literature. (C) 2013 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:142 / 158
页数:17
相关论文
共 31 条
[1]   Turbulent penetrative and recirculating flow in a compartment fire [J].
Abib, AH ;
Jaluria, Y .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1995, 117 (04) :927-935
[2]   NUMERICAL-SIMULATION OF THE BUOYANCY-INDUCED FLOW IN A PARTIALLY OPEN ENCLOSURE [J].
ABIB, AH ;
JALURIA, Y .
NUMERICAL HEAT TRANSFER, 1988, 14 (02) :235-254
[3]   Smoke movement driven by a fire under a ceiling [J].
Atkinson, G .
FIRE SAFETY JOURNAL, 1995, 25 (03) :261-275
[4]   A NUMERICAL STUDY OF TWO-DIMENSIONAL LAMINAR NATURAL-CONVECTION IN SHALLOW OPEN CAVITIES [J].
CHAN, YL ;
TIEN, CL .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1985, 28 (03) :603-612
[5]  
Chen Qingyan, 2007, BUILD ENVIRON, V42, P2819
[6]  
Chow W.K., 2009, BUILD ENVIRON, V44, P848
[7]  
COOPER LY, 1981, FIRE SAFETY J, V3, P201
[8]   CALCULATION OF THE TURBULENT BUOYANCY-DRIVEN FLOW IN A RECTANGULAR CAVITY USING AN EFFICIENT SOLVER AND 2 DIFFERENT LOW REYNOLDS-NUMBER K-EPSILON TURBULENCE MODELS [J].
DAVIDSON, L .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 1990, 18 (02) :129-147
[9]  
DAVIS GD, 1983, INT J NUMER METH FL, V3, P249
[10]   Simulation of high Rayleigh number natural convection in a square cavity using the lattice Boltzmann method [J].
Dixit, HN ;
Babu, V .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (3-4) :727-739