Scheimpflug Corneal Densitometry Changes After the Intrastromal Corneal Ring Segment Implantation

被引:5
|
作者
Sedaghat, Mohammad-Reza [1 ]
Momeni-Moghaddam, Hamed [2 ,3 ]
Heravian, Javad [3 ,4 ]
Belin, Michael W. [5 ]
Ambrosio, Renato, Jr. [6 ,7 ]
Gheysari-Alishahi, Tayebe [2 ]
Ghavami, Seyyed Hossein [1 ]
机构
[1] Mashhad Univ Med Sci, Eye Res Ctr, Mashhad, Razavi Khorasan, Iran
[2] Zahedan Univ Med Sci, Hlth Promot Res Ctr, Zahedan, Iran
[3] Mashhad Univ Med Sci, Sch Paramed Sci, Dept Optometry, Mashhad, Razavi Khorasan, Iran
[4] Mashhad Univ Med Sci, Sch Paramed Sci, Refract Errors Res Ctr, Mashhad, Razavi Khorasan, Iran
[5] Univ Arizona, Dept Ophthalmol & Vis Sci, Tucson, AZ USA
[6] Rio de Janeiro Corneal Tomog & Biomech Study Grp, Rio De Janeiro, Brazil
[7] Fed Univ State Rio de Janeiro, Dept Ophthalmol, Rio De Janeiro, Brazil
关键词
keratoconus; intrastromal corneal ring segments; corneal densitometry; Scheimpflug tomography; scattering; CROSS-LINKING; KERATOCONUS; OUTCOMES; TRANSPARENCY; VALUES; LENS;
D O I
10.1097/ICO.0000000000002307
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the changes in corneal backward scattering using Scheimpflug tomography (densitometry) 6 months after intrastromal corneal ring segments (Keraring) implant for keratoconus and to correlate with clinical results. Methods: Along with standard ophthalmic examination, Scheimpflug tomography using Pentacam HR was performed to document corneal densitometry and corneal shape. A densitometry map was displayed using grayscale units (GSUs) ranging from 0 to 100 (minimum to maximum light scattering) in 4 concentric annuluses: central 2-, 2- to 6-, 6- to 10-, 10- to 12-, and total 12-mm corneal diameter and at 3 different depths: anterior 120 mu m, posterior 60 mu m, middle (varying accordingly to the total thickness), and total thickness. Results: The changes in mean corneal densitometry values for anterior, central, and posterior layers were 3.82 +/- 3.13, 2.70 +/- 1.78, and 1.68 +/- 1.52 GSU, respectively, and for annuluses of 0 to 2, 2 to 6, 6 to 10, and 10 to 12 mm were 2.96 +/- 2.60, 4.53 +/- 2.28, 2.09 +/- 1.74, and 0.45 +/- 3.93 GSU, respectively. The mean values increased for all corneal layers (P< 0.05), except in the peripheral 10- to 12-mm annulus (P> 0.05). The highest increase was in the annulus 2 to 6 mm of the anterior layer (5.72 +/- 3.70 GSU). Changes in the mean densitometry showed a significant correlation with the mean of average keratometry changes only for the front corneal surface and changes in the Q-values for both corneal surfaces in the 2- to 6-mm annulus for all layers. Conclusions: Significant increase in the corneal densitometry mainly in the anterior 2- to 6-mm annulus of the cornea is associated with the position of the ring segment implant. More studies are needed to elucidate the relevance of such findings.
引用
收藏
页码:761 / 768
页数:8
相关论文
共 50 条
  • [1] Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
    Basiony, Ahmed I.
    Abdulfattah, Mohammad M. E. Mohammad
    Ibrahim, Asmaa M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (01) : 28 - 38
  • [2] Corneal hydrops after intrastromal corneal ring segment implantation
    Kaya, Vedat
    Kaynak, Pelin
    Basarir, Berna
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (05): : 816 - 816
  • [3] Acute corneal hydrops after intrastromal corneal ring segment implantation for keratoconus
    Gueell, Jose L.
    Verdaguer, Paula
    Elies, Daniel
    Gris, Oscar
    Manero, Felicidad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12): : 2192 - 2195
  • [4] Microbial Keratitis After Intrastromal Corneal Ring Segment Implantation
    Emilia Mulet, M.
    Perez-Santonja, Juan J.
    Ferrer, Consuelo
    Alio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 364 - 369
  • [5] Changes in Anterior and Posterior Corneal Parameters in Patients with Keratoconus After Intrastromal Corneal-ring Segment Implantation
    Rho, Chang Rae
    Na, Kyung-Sun
    Yoo, Young Sik
    Pandey, Chitra
    Park, Chang Won
    Joo, Choun-Ki
    CURRENT EYE RESEARCH, 2013, 38 (08) : 843 - 850
  • [6] Intrastromal corneal ring segment implantation for ectasia after refractive surgery
    Souza Stival, Larissa Rossana
    do Amaral Nassaralla, Belquiz R.
    Falleiro Chaves de Figueiredo, Marisa Novaes
    Bicalho, Frederico
    Nassaralla Junior, Joao Jorge
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2015, 78 (04) : 212 - 215
  • [7] INTRASTROMAL CORNEAL RING SEGMENT IMPLANTATION FOR ECTASIA AFTER REFRACTIVE SURGERY
    Stival, Larissa Rossana
    Nassaralla, Belquiz A.
    Figueiredo, Marisa
    Bicalho, Frederico
    Nassaralla, Joao J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [8] Scheimpflug Corneal Densitometry Changes After Trabeculectomy
    Pillunat, Karin R.
    Orphal, Johanna
    Haase, Maike
    Pillunat, Lutz E.
    Herber, Robert
    CORNEA, 2021, 40 (04) : 408 - 414
  • [9] Intrastromal corneal ring segment implantation for ectasia after refractive surgery
    Torquetti, Leonardo
    Ferrara, Paulo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06): : 986 - 990
  • [10] Intrastromal Corneal Ring Segment Implantation for the Treatment of Keratoconus
    Kubaloglu, Anil
    Sari, Esin Sogutlu
    Cinar, Yasin
    Koytak, Arif
    Kurnaz, Ekrem
    Ozerturk, Yusuf
    CORNEA, 2011, 30 (01) : 11 - 17