Three-dimensional assessment of robot-assisted pedicle screw placement accuracy and instrumentation reliability based on a preplanned trajectory

被引:33
作者
Jiang, Bowen [1 ]
Pennington, Zach [1 ]
Zhu, Alex [1 ]
Matsoukas, Stavros [2 ]
Ahmed, A. Karim [1 ]
Ehresman, Jeff [1 ]
Mahapatra, Smruti [3 ]
Cottrill, Ethan [1 ]
Sheppell, Hailey [3 ]
Manbachi, Amir [3 ]
Crawford, Neil [4 ]
Theodore, Nicholas [1 ]
机构
[1] Johns Hopkins Sch Med, Dept Neurosurg, Baltimore, MD USA
[2] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD USA
[3] Aristotle Univ Thessaloniki, Sch Med, Thessaloniki, Greece
[4] Globus Med, Audubon, PA USA
关键词
robot assistance; pedicle screw accuracy; three-dimensional accuracy; surgical technique; IMAGE QUALITY; GUIDANCE; RECONSTRUCTION; INSERTION; HEAD;
D O I
10.3171/2020.3.SPINE20208
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE Robotic spine surgery systems are increasingly used in the US market. As this technology gains traction, however, it is necessary to identify mechanisms that assess its effectiveness and allow for its continued improvement. One such mechanism is the development of a new 3D grading system that can serve as the foundation for error-based learning in robot systems. Herein the authors attempted 1) to define a system of providing accuracy data along all three pedicle screw placement axes, that is, cephalocaudal, mediolateral, and screw long axes; and 2) to use the grading system to evaluate the mean accuracy of thoracolumbar pedicle screws placed using a single commercially available robotic system. METHODS The authors retrospectively reviewed a prospectively maintained, IRB-approved database of patients at a single tertiary care center who had undergone instrumented fusion of the thoracic or lumbosacral spine using robotic assistance. Patients with preoperatively planned screw trajectories and postoperative CT studies were included in the final analysis. Screw accuracy was measured as the net deviation of the planned trajectory from the actual screw trajectory in the mediolateral, cephalocaudal, and screw long axes. RESULTS The authors identified 47 patients, 51% male, whose pedicles had been instrumented with a total of 254 screws (63 thoracic, 191 lumbosacral). The patients had a mean age of 61.1 years and a mean BMI of 30.0 kg/m(2). The mean screw tip accuracies were 1.3 +/- 1.3 mm, 1.2 +/- 1.1 mm, and 2.6 +/- 2.2 mm in the mediolateral, cephalocaudal, and screw long axes, respectively, for a net linear deviation of 3.6 +/- 2.3 mm and net angular deviation of 3.6 degrees +/- 2.8 degrees. According to the Gertzbein-Robbins grading system, 184 screws (72%) were classified as grade A and 70 screws (28%) as grade B. Placement of 100% of the screws was clinically acceptable. CONCLUSIONS The accuracy of the discussed robotic spine system is similar to that described for other surgical systems. Additionally, the authors outline a new method of grading screw placement accuracy that measures deviation in all three relevant axes. This grading system could provide the error signal necessary for unsupervised machine learning by robotic systems, which would in turn support continued improvement in instrumentation placement accuracy.
引用
收藏
页码:519 / 528
页数:10
相关论文
共 27 条
  • [1] A method of lumbar pedicle screw placement optimization applied to guidance techniques
    Chen Xiaozhao
    Huang Jinfeng
    Mao Baolin
    Yan Chongnan
    Kang Yan
    [J]. Computer Assisted Surgery, 2016, 21 : 143 - 148
  • [2] The impact of CBCT reconstruction and calibration for radiotherapy planning in the head and neck region - a phantom study
    Elstrom, Ulrik V.
    Olsen, Sune R. K.
    Muren, Ludvig P.
    Petersen, Jorgen B. B.
    Grau, Cai
    [J]. ACTA ONCOLOGICA, 2014, 53 (08) : 1114 - 1124
  • [3] Evaluation of image quality for different kV cone-beam CT acquisition and reconstruction methods in the head and neck region
    Elstrom, Ulrik V.
    Muren, Ludvig P.
    Petersen, Jorgen B. B.
    Grau, Cai
    [J]. ACTA ONCOLOGICA, 2011, 50 (06) : 908 - 917
  • [4] FAN Y, 2018, MEDICINE, V97, DOI DOI 10.1097/MD.0000000000010970
  • [5] Radiological and clinical differences among three assisted technologies in pedicle screw fixation of adult degenerative scoliosis
    Fan, Yong
    Du, Jin Peng
    Liu, Ji Jun
    Zhang, Jia Nan
    Liu, Shi Chang
    Hao, Ding Jun
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [6] Robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis of randomized controlled trials
    Gao, Shutao
    Lv, Zhengtao
    Fang, Huang
    [J]. EUROPEAN SPINE JOURNAL, 2018, 27 (04) : 921 - 930
  • [7] A study on image quality provided by a kilovoltage cone-beam computed tomography
    Garayoa, Julia
    Castro, Pablo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 239 - 257
  • [8] ACCURACY OF PEDICULAR SCREW PLACEMENT INVIVO
    GERTZBEIN, SD
    ROBBINS, SE
    [J]. SPINE, 1990, 15 (01) : 11 - 14
  • [9] The Arrival of Robotics in Spine Surgery A Review of the Literature
    Ghasem, Alexander
    Sharma, Akhil
    Greif, Dylan N.
    Alam, Milad
    Al Maaieh, Motasem
    [J]. SPINE, 2018, 43 (23) : 1670 - 1677
  • [10] A Quantitative Assessment of the Accuracy and Reliability of Robotically Guided Percutaneous Pedicle Screw Placement: Technique and Application Accuracy
    Godzik, Jakub
    Walker, Corey T.
    Hartman, Cory
    de Andrada, Bernardo
    Morgan, Clinton D.
    Mastorakos, George
    Chang, Steven
    Turner, Jay
    Porter, Randall W.
    Snyder, Laura
    Uribe, Juan
    [J]. OPERATIVE NEUROSURGERY, 2019, 17 (04) : 389 - 395