Systematic analysis of bias and variability of morphologic features for lung lesions in computed tomography

被引:11
|
作者
Hoye, Jocelyn [1 ,2 ,3 ,4 ]
Solomon, Justin [1 ,2 ,3 ,4 ]
Sauer, Thomas J. [1 ,2 ,3 ,4 ]
Robins, Marthony [1 ,2 ,3 ,4 ]
Samei, Ehsan [1 ,2 ,3 ,4 ]
机构
[1] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27708 USA
[2] Duke Univ, Med Phys Grad Program, Durham, NC 27708 USA
[3] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[4] Duke Univ, Med Ctr, Durham, NC 27708 USA
关键词
morphology; lung lesions; quantitative imaging; computed tomography; imaging conditions; RADIOMICS; RECONSTRUCTION; IMAGES; MODEL;
D O I
10.1117/1.JMI.6.1.013504
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We propose to characterize the bias and variability of quantitative morphology features of lung lesions across a range of computed tomography (CT) imaging conditions. A total of 15 lung lesions were simulated (five in each of three spiculation classes: low, medium, and high). For each lesion, a series of simulated CT images representing different imaging conditions were synthesized by applying three-dimensional blur and adding correlated noise based on the measured noise and resolution properties of five commercial multislice CT systems, representing three dose levels (CTDIvol of 1.90, 3.75, 7.50 mGy), three slice thicknesses (0.625, 1.25, 2.5 mm), and 33 clinical reconstruction kernels from five clinical scanners. The images were segmented using three segmentation algorithms and each algorithm was evaluated by computing a Sorensen-Dice coefficient between the ground truth and the segmentation. A series of 21 shape-based morphology features were extracted from both "ground truth" (i.e., preblur without noise) and "image rendered" lesions (i.e., postblur and with noise). For each morphology feature, the bias was quantified by comparing the percentage relative error in the morphology metric between the imaged lesions and the ground-truth lesions. The variability was characterized by calculating the average coefficient of variation averaged across repeats and imaging conditions. The active contour segmentation had the highest average Dice coefficient of 0.80 followed by 0.63 for threshold, and 0.39 for fuzzy c-means. The bias of the features was segmentation algorithm and feature-dependent, with sharper kernels being less biased and smoother kernels being more biased in general. The feature variability from simulated images ranged from 0.30% to 10% for repeats of the same condition and from 0.74% to 25.3% for different lesions in the same spiculation class. In conclusion, the bias of morphology features is dependent on the acquisition protocol in combination with the segmentation algorithm used and the variability is primarily dependent on the segmentation algorithm. (C) 2019 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Preliminary Report on Computed Tomography Radiomics Features as Biomarkers to Immunotherapy Selection in Lung Adenocarcinoma Patients
    Granata, Vincenza
    Fusco, Roberta
    Costa, Matilde
    Picone, Carmine
    Cozzi, Diletta
    Moroni, Chiara
    La Casella, Giorgia Viola
    Montanino, Agnese
    Monti, Riccardo
    Mazzoni, Francesca
    Grassi, Roberta
    Malagnino, Valeria Grazia
    Cappabianca, Salvatore
    Grassi, Roberto
    Miele, Vittorio
    Petrillo, Antonella
    CANCERS, 2021, 13 (16)
  • [22] Pictorial review of computed tomography features of diffuse cystic lung disease
    Chan, Yi Lam Priscilla
    Yu, Chun Hung Kevin
    Chong, Wing Ho
    Kwok, Kai Yan
    Li, Allen
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2022, 12 : 1 - 8
  • [23] The value of 4D fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography in the diagnosis of lung lesions
    Zhang, Lixia
    Chen, Jinyan
    Xu, Caiyun
    Zhang, Yin
    Qi, Lili
    Zhang, Xiyan
    NUCLEAR MEDICINE COMMUNICATIONS, 2020, 41 (12) : 1306 - 1312
  • [24] COMPUTED TOMOGRAPHY GUIDED FINE NEEDLE ASPIRATION CYTOLOGY OF MASS LESIONS OF LUNG: A STUDY IN CENTRAL INDIA
    Gupta, Vivek
    Valecha, Jyoti
    Mishra, Jharna
    Chanchlani, Roshan
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (21): : 5742 - 5747
  • [25] Computed Tomography Features and Tumor Spread Through Air Spaces in Lung Adenocarcinoma A Meta-analysis
    Gu, Yan
    Zheng, Bo
    Zhao, Tianjing
    Fan, Yingjie
    JOURNAL OF THORACIC IMAGING, 2023, 38 (02) : W19 - W29
  • [26] Regional Lung Perfusion Analysis in Experimental ARDS by Electrical Impedance and Computed Tomography
    Kircher, Michael
    Elke, Gunnar
    Stender, Birgit
    Hernandez Mesa, Maria
    Schuderer, Felix
    Doessel, Olaf
    Fuld, Matthew K.
    Halaweish, Ahmed F.
    Hoffman, Eric A.
    Weiler, Norbert
    Frerichs, Inez
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (01) : 251 - 261
  • [27] Exploring features towards semantic characterization of lung nodules in Computed Tomography images
    Macedo, Maysa M. G.
    Oliveira, Dario A. B.
    MEDICAL IMAGING 2019: COMPUTER-AIDED DIAGNOSIS, 2019, 10950
  • [28] Logistic regression analysis of texture features of thyroid calcification based on computed tomography images
    Chen, Kexin
    Chen, Jiaxing
    Qian, Yijia
    Ye, Meng
    Xu, Lu
    Chen, Shanshan
    Liu, Chenbin
    Chen, Yihong
    Peng, Wenxian
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 13 (01): : 112 - 117
  • [29] Computed tomography features of resected lung adenocarcinomas with spread through air spaces
    Toyokawa, Gouji
    Yamada, Yuichi
    Tagawa, Tetsuzo
    Kamitani, Takeshi
    Yamasaki, Yuzo
    Shimokawa, Mototsugu
    Oda, Yoshinao
    Maehara, Yoshihiko
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 156 (04) : 1670 - +
  • [30] Computed Tomography (CT)-Guided Needle Biopsy of Lung Lesions: A Single Center Experience
    Ezenagu, Oluebube C.
    Gabriel, Gaby E.
    Saha, Sibu P.
    HEALTHCARE, 2024, 12 (13)