Computer-aided detection of lung nodules using outer surface features

被引:32
|
作者
Demir, Onder [1 ]
Camurcu, Ali Yilmaz [2 ]
机构
[1] Marmara Univ, Dept Comp Engn, Fac Technol, TR-34722 Istanbul, Turkey
[2] Fatih Sultan Mehmet Vakif Univ, Fac Engn, Comp Engn Dept, TR-34445 Istanbul, Turkey
关键词
Lung nodule detection; CAD systems; texture features; medical image processing; classification; IMAGE DATABASE CONSORTIUM; AUTOMATIC DETECTION; PULMONARY NODULES; CT SCANS; SEGMENTATION; ALGORITHM; CLASSIFICATION; LIDC;
D O I
10.3233/BME-151418
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, a computer-aided detection (CAD) system was developed for the detection of lung nodules in computed tomography images. The CAD system consists of four phases, including two-dimensional and three-dimensional preprocessing phases. In the feature extraction phase, four different groups of features are extracted from volume of interests: morphological features, statistical and histogram features, statistical and histogram features of outer surface, and texture features of outer surface. The support vector machine algorithm is optimized using particle swarm optimization for classification. The CAD system provides 97.37% sensitivity, 86.38% selectivity, 88.97% accuracy and 2.7 false positive per scan using three groups of classification features. After the inclusion of outer surface texture features, classification results of the CAD system reaches 98.03% sensitivity, 87.71% selectivity, 90.12% accuracy and 2.45 false positive per scan. Experimental results demonstrate that outer surface texture features of nodule candidates are useful to increase sensitivity and decrease the number of false positives in the detection of lung nodules in computed tomography images.
引用
收藏
页码:S1213 / S1222
页数:10
相关论文
共 50 条
  • [41] Computer-aided detection of pulmonary nodules at chest radiography and CT
    Mori, M
    Takabatake, H
    Natori, H
    Mitani, M
    Suzuki, H
    Inaoka, N
    RADIOLOGY, 1996, 201 : 9715 - 9715
  • [42] Computer-aided detection and automated CT volumetry of pulmonary nodules
    Marten, Katharina
    Engelke, Christoph
    EUROPEAN RADIOLOGY, 2007, 17 (04) : 888 - 901
  • [43] A comparison of axial versus coronal image viewing in computer-aided detection of lung nodules on CT
    Iwasawa, Tae
    Matsumoto, Sumiaki
    Aoki, Takatoshi
    Okada, Fumito
    Nishimura, Yoshihiro
    Yamagata, Hitoshi
    Ohno, Yoshiharu
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (02) : 76 - 83
  • [44] Performance analysis of a computer-aided detection system for lung nodules in CT at different slice thicknesses
    Narayanan, Barath Narayanan
    Hardie, Russell Craig
    Kebede, Temesguen Messay
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)
  • [45] Computer-aided detection of lung nodules on chest CT: Issues to be solved before clinical use
    Goo, JM
    KOREAN JOURNAL OF RADIOLOGY, 2005, 6 (02) : 62 - 63
  • [46] A comparison of axial versus coronal image viewing in computer-aided detection of lung nodules on CT
    Tae Iwasawa
    Sumiaki Matsumoto
    Takatoshi Aoki
    Fumito Okada
    Yoshihiro Nishimura
    Hitoshi Yamagata
    Yoshiharu Ohno
    Japanese Journal of Radiology, 2015, 33 : 76 - 83
  • [47] Computer-aided detection of lung nodules by SVM based on 3D matrix patterns
    Wang, Qingzhu
    Kang, Wenwei
    Wu, Chunming
    Wang, Bin
    CLINICAL IMAGING, 2013, 37 (01) : 62 - 69
  • [48] A computer-aided diagnosis system for detection of lung nodules in chest radiographs with an evaluation on a public database
    Schilham, AMR
    van Ginneken, B
    Loog, M
    MEDICAL IMAGE ANALYSIS, 2006, 10 (02) : 247 - 258
  • [49] A Computer Aided Diagnosis for detection and classification of lung nodules
    Narayanan, Lakshmi A.
    Jeeva, J. B.
    PROCEEDINGS OF 2015 IEEE 9TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS AND CONTROL (ISCO), 2015,
  • [50] False-positive reduction using hessian features in computer-aided detection of pulmonary nodules on thoracic CT images
    Sahiner, B
    Ge, ZY
    Chan, HP
    Hadjiiski, LM
    Bogot, N
    Cascade, PN
    Kazerooni, EA
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 790 - 795