Nitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume

被引:94
作者
Chiumello, Davide [1 ]
Cressoni, Massimo [2 ]
Chierichetti, Monica [2 ]
Tallarini, Federica [2 ]
Botticelli, Marco [2 ]
Berto, Virna [2 ]
Mietto, Cristina [2 ]
Gattinoni, Luciano [1 ,2 ]
机构
[1] Osped Maggiore, Policlin Mangiagalli Regina Elena, Fdn IRCCS, Dipartimento Anestesia Rianimaz Intens & Subinten, I-20122 Milan, Italy
[2] Univ Milan, Osped Maggiore, Policlin Mangiagalli Regina Elena, Fdn IRCCS,Ist Anestesiol & Rianimaz, I-20122 Milan, Italy
来源
CRITICAL CARE | 2008年 / 12卷 / 06期
关键词
D O I
10.1186/cc7139
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction End expiratory lung volume (EELV) measurement in the clinical setting is routinely performed using the helium dilution technique. A ventilator that implements a simplified version of the nitrogen washout/washin technique is now available. We compared the EELV measured by spiral computed tomography (CT) taken as gold standard with the lung volume measured with the modified nitrogen washout/washin and with the helium dilution technique. Methods Patients admitted to the general intensive care unit of Ospedale Maggiore Policlinico Mangiagalli Regina Elena requiring ventilatory support and, for clinical reasons, thoracic CT scanning were enrolled in this study. We performed two EELV measurements with the modified nitrogen washout/washin technique (increasing and decreasing inspired oxygen fraction (FiO(2)) by 10%), one EELV measurement with the helium dilution technique and a CT scan. All measurements were taken at 5 cmH(2)O airway pressure. Each CT scan slice was manually delineated and gas volume was computed with custom-made software. Results Thirty patients were enrolled (age = 66 +/- 10 years, body mass index = 26 +/- 18 Kg/m(2), male/female ratio = 21/9, partial arterial pressure of carbon dioxide (PaO2)/FiO(2) = 190 +/- 71). The EELV measured with the modified nitrogen washout/washin technique showed a very good correlation (r(2) = 0.89) with the data computed from the CT with a bias of 94 +/- 143 ml (15 +/- 18%, p = 0.001), within the limits of accuracy declared by the manufacturer (20%). The bias was shown to be highly reproducible, either decreasing or increasing the FiO(2) being 117+/- 170 and 70+/- 160 ml (p = 0.27), respectively. The EELV measured with the helium dilution method showed a good correlation with the CT scan data (r(2) = 0.91) with a negative bias of 136 +/- 133 ml, and appeared to be more correct at low lung volumes. Conclusions The EELV measurement with the helium dilution technique (at low volumes) and modified nitrogen washout/washin technique (at all lung volumes) correlates well with CT scanning and may be easily used in clinical practice.
引用
收藏
页数:8
相关论文
共 26 条
[1]   A CORRECTION FACTOR FOR HELIUM ABSORPTION IN LUNG VOLUME DETERMINATIONS [J].
BIRATH, G ;
SWENSON, EW .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1956, 8 (02) :155-158
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Chiumello D, 2007, MINERVA ANESTESIOL, V73, P109
[4]   Mechanical ventilation affects local and systemic cytokines in an animal model of acute respiratory distress syndrome [J].
Chiumello, D ;
Pristine, G ;
Slutsky, AS .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (01) :109-116
[5]   Lung stress and strain during mechanical ventilation for acute respiratory distress syndrome [J].
Chiumello, Davide ;
Carlesso, Eleonora ;
Cadringher, Paolo ;
Caironi, Pietro ;
Valenza, Franco ;
Polli, Federico ;
Tallarini, Feclerica ;
Cozzi, Paola ;
Cressoni, Massimo ;
Colombo, Angelo ;
Marini, John J. ;
Gattinoni, Luciano .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2008, 178 (04) :346-355
[6]   PERIOPERATIVE CHANGES IN FUNCTIONAL RESIDUAL CAPACITY IN MORBIDLY OBESE PATIENTS [J].
DAMIA, G ;
MASCHERONI, D ;
CROCI, M ;
TARENZI, L .
BRITISH JOURNAL OF ANAESTHESIA, 1988, 60 (05) :574-578
[7]  
DREYFUSS D, 1985, AM REV RESPIR DIS, V132, P880
[8]   HIGH INFLATION PRESSURE PULMONARY-EDEMA - RESPECTIVE EFFECTS OF HIGH AIRWAY PRESSURE, HIGH TIDAL VOLUME, AND POSITIVE END-EXPIRATORY PRESSURE [J].
DREYFUSS, D ;
SOLER, P ;
BASSET, G ;
SAUMON, G .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (05) :1159-1164
[9]  
Durig A, 1903, ZENTRALBL PHYSL, V17, P258
[10]   A SIMPLE METHOD TO ESTIMATE FUNCTIONAL RESIDUAL CAPACITY IN MECHANICALLY VENTILATED PATIENTS [J].
FRETSCHNER, R ;
DEUSCH, H ;
WEITNAUER, A ;
BRUNNER, JX .
INTENSIVE CARE MEDICINE, 1993, 19 (07) :372-376